A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer

被引:32
|
作者
Gasic, Daniel [1 ]
Ohlhues, Lars [1 ]
Brodin, N. Patrik [2 ]
Fog, Lotte S. [1 ]
Pommer, Tobias [1 ,3 ]
Bangsgaard, Jens P. [1 ]
Rosenschold, Per Munck A. F. [1 ,3 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Sect Radiotherapy, Copenhagen, Denmark
[2] Albert Einstein Coll Med, Inst Oncophys, Bronx, NY 10461 USA
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
关键词
STEREOTACTIC BODY RADIOTHERAPY; FREE BEAMS; PHOTON BEAMS; IMRT; SBRT; FEASIBILITY; VMAT; PATIENT;
D O I
10.3109/0284186X.2014.925578
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. Methods. A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD-and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. Results. For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. Conclusion. It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [31] Dosimetric comparison of intensity-modulated radiation therapy and volumetric-modulated arc therapy plans for the treatment of glioma using flattening filter-free and flattening filter modes
    Xu, Dandan
    Jia, Fei
    Li, Guowen
    Li, Hongfei
    ONCOLOGY LETTERS, 2017, 13 (05) : 3451 - 3456
  • [32] Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes
    Zhang, W.
    Zhang, J.
    Lu, J.
    Chen, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3404 - 3404
  • [33] Volumetric Modulated Arc Therapy (VMAT) treatment planning for prostate - a comparison of Flatness Filter Free (FFF) and flat beam plans
    Treutwein, M.
    Hipp, M.
    Koelbl, O.
    Dobler, B.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 51 - 51
  • [34] Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer
    Hall, William A.
    Fox, Timothy H.
    Jiang, Xiaojun
    Prabhu, Roshan S.
    Rossi, Peter J.
    Godette, Karen
    Jani, Ashesh B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (02) : 128 - 134
  • [35] Dosimetric Comparison for Unfavorable Early Stage Lung Cancer: Intensity Modulated Proton Therapy Versus Volumetric Arc Photon Therapy
    O'Reilly, S.
    Singh, P.
    Hartl, B.
    Diffenderfer, E.
    Cengel, K.
    Levin, W.
    Berman, A.
    Feigenberg, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [36] Treatment planning comparison between dynamic wave arc and volumetric modulated arc therapies for prostate-cancer treatment
    Miura, Hideharu
    Nakao, Minoru
    Doi, Yoshiko
    Ozawa, Shuichi
    Kenjo, Masahiko
    Nagata, Yasushi
    MEDICAL DOSIMETRY, 2022, 47 (01) : 48 - 53
  • [37] Dosimetric comparison of head and neck cancer patients planned with multivendor volumetric modulated arc therapy technology
    Kathirvel, Murugesan
    Subramani, Vellaiyan
    Subramanian, V. S.
    Swamy, Shanmugam Thirumalai
    Arun, Gandhi
    Kala, Subramanian
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (01) : 122 - 130
  • [38] The effect of photon energy on dose distribution in volumetric-modulated arc therapy planning for head and neck cancer
    Nguyen, Trang Hong Thi
    Takemura, Akihiro
    Ueda, Shinichi
    Noto, Kimiya
    Kojima, Hironori
    Isomura, Naoki
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 316 - 320
  • [39] Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems
    Tsutsumi, Shinichi
    Hosono, Masako N.
    Tatsumi, Daisaku
    Miki, Yoshitaka
    Masuoka, Yutaka
    Ogino, Ryo
    Ishii, Kentaro
    Shimatani, Yasuhiko
    Miki, Yukio
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [40] Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?
    Quan, Enzhuo M.
    Chang, Joe Y.
    Liao, Zhongxing
    Xia, Tingyi
    Yuan, Zhiyong
    Liu, Hui
    Li, Xiaoqiang
    Wages, Cody A.
    Mohan, Radhe
    Zhang, Xiaodong
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (01): : E69 - E76