摘要
Background. Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. Methods. A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD-and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. Results. For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. Conclusion. It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [1] Comparison of skin dose of flattening filter and flattening filter-free beam in volumetric modulated arc therapy treatment plan for head and neck cancer
    Lam Pham Hong
    Dung Phan Tien
    Thai Hoang Huu
    Lam Nguyen Tung
    Tu Nguyen Duong
    Van Anh Nguyen Thi
    Trang Pham Quang
    2023 1ST INTERNATIONAL CONFERENCE ON HEALTH SCIENCE AND TECHNOLOGY, ICHST 2023, 2023,
  • [2] Comparison of Moderate Hypofractionated Volumetric-Modulated Arc Therapy Plans With and Without Flattening Filter for Localized Prostate Cancer
    Takakusagi, Yosuke
    Usui, Keisuke
    Mizoguchi, Nobutaka
    Nagatsuka, Jun
    Hikage, Takeshi
    Kodama, Yasuhiko
    Ezura, Takatomo
    Kusunoki, Terufumi
    Oizumi, Yukio
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [3] Comparison between flattening filter and flattening filter-free photon beams in head and neck cancer patients using volumetric modulated arc therapy technique
    Alfishawy, Mahmoud Mohamed
    Elshahat, Khaled Mohamed
    Kany, Amr Ismail
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2025, : 67 - 76
  • [4] Stereotactic ablative radiation therapy for brain metastases with volumetric modulated arc therapy and flattening filter free delivery: feasibility and early clinical results
    Fiorentino, Alba
    Giaj-Levra, Niccolo
    Tebano, Umberto
    Mazzola, Rosario
    Ricchetti, Francesco
    Fersino, Sergio
    Di Paola, Gioacchino
    Aiello, Dario
    Ruggieri, Ruggero
    Alongi, Filippo
    RADIOLOGIA MEDICA, 2017, 122 (09): : 676 - 682
  • [5] Stereotactic ablative radiation therapy for brain metastases with volumetric modulated arc therapy and flattening filter free delivery: feasibility and early clinical results
    Alba Fiorentino
    Niccolò Giaj-Levra
    Umberto Tebano
    Rosario Mazzola
    Francesco Ricchetti
    Sergio Fersino
    Gioacchino Di Paola
    Dario Aiello
    Ruggero Ruggieri
    Filippo Alongi
    La radiologia medica, 2017, 122 : 676 - 682
  • [6] Volumetric Modulated Arc Therapy for Head and Neck Cancer: A Dosimetric and Treatment Planning Comparison with Intensity Modulated Radiotherapy Techniques
    Goswami, Brijesh
    Yadav, Suresh
    Jain, Rakesh Kumar
    Goswami, Pradeep
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (03)
  • [7] Large, Half-Beam, Flattening Filter Free Volumetric Modulated Arc Therapy for Head and Neck Cancer Radiation Therapy
    Hajdok, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S944 - S944
  • [8] Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT) with and without Flattening Filter for Stereotactic Body Radiation Therapy (SBRT) in Localised Prostate Cancer
    Cher, S. J. Y.
    Chan, T. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E104 - E104
  • [9] ROLE OF VOLUMETRIC MODULATED ARC THERAPY WITH FLATTENING FILTER FREE DELIVERY IN LUNG STEREOTACTIC BODY RADIOTHERAPY
    Liu, Hongwei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S68 - S68
  • [10] Volumetric-modulated arc therapy and intensity-modulated radiation therapy treatment planning for prostate cancer with flattened beam and flattening filter free linear accelerators
    Treutwein, Marius
    Hipp, Matthias
    Koelbl, Oliver
    Dobler, Barbara
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 307 - 314