Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

被引:232
|
作者
McMullan, G. [1 ]
Faruqi, A. R. [1 ]
Clare, D. [2 ,3 ]
Henderson, R. [1 ]
机构
[1] MRC, Mol Biol Lab, Cambridge CB2 0QH, England
[2] Univ London, Birkbeck Coll, London WC1E 7HX, England
[3] Univ London, Birkbeck Coll, Inst Struct & Mol Biol, London WC1E 7HX, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
DQE; MTF; CMOS; NOISE TRANSFER; CCD CAMERAS; CRYO-EM; SIGNAL;
D O I
10.1016/j.ultramic.2014.08.002
中图分类号
TH742 [显微镜];
学科分类号
摘要
Low dose electron imaging applications such as electron cryo-microscopy are now benefit:Ling from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three defectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. (C) 2014 The Authors. Published by Elsevier B.V.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 50 条
  • [41] Direct comparison of optical and electron microscopy methods for structural characterization of extracellular vesicles
    Noble, Jade M.
    Roberts, LaDeidra Monet
    Vidavsky, Netta
    Chiou, Aaron E.
    Fischbach, Claudia
    Paszek, Matthew J.
    Estroff, Lara A.
    Kourkoutis, Lena F.
    JOURNAL OF STRUCTURAL BIOLOGY, 2020, 210 (01)
  • [42] COMPARISON OF ROTAZYME AND DIRECT ELECTRON-MICROSCOPY FOR DETECTION OF ROTAVIRUS IN HUMAN STOOLS
    CHEUNG, EY
    HNATKO, SI
    GUNNING, H
    WILSON, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 16 (03) : 562 - 563
  • [43] High-resolution low-dose scanning transmission electron microscopy
    Buban, James P.
    Ramasse, Quentin
    Gipson, Bryant
    Browning, Nigel D.
    Stahlberg, Henning
    JOURNAL OF ELECTRON MICROSCOPY, 2010, 59 (02): : 103 - 112
  • [44] ON THE STATISTICAL-ANALYSIS OF IMAGES IN LOW-DOSE ELECTRON-MICROSCOPY
    SLUMP, CH
    FERWERDA, HA
    HOENDERS, BJ
    ULTRAMICROSCOPY, 1984, 15 (04) : 377 - 378
  • [45] LOW-DOSE HIGH-RESOLUTION ELECTRON-MICROSCOPY OF POLYMERS
    MARTIN, DC
    WILSON, PM
    LIAO, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 12 - POLY
  • [46] Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose
    Wei, Jingrui
    Moore, Kalani
    Bammes, Benjamin
    Levin, Barnaby D. A.
    Hagopian, Nicholas
    Jacobs, Ryan
    Morgan, Dane
    Voyles, Paul M.
    MICROSCOPY AND MICROANALYSIS, 2023, 29 (06) : 2026 - 2036
  • [47] LOW-DOSE ELECTRON-MICROSCOPY OF THE CROTOXIN COMPLEX THIN CRYSTAL
    JENG, TW
    CHIU, W
    JOURNAL OF MOLECULAR BIOLOGY, 1983, 164 (02) : 329 - 346
  • [48] Three-dimensional visualization of lithium metal anode via low-dose cryogenic electron microscopy tomography
    Xiangya, Li
    Han, Bing
    Yang, Xuming
    Deng, Zhipeng
    Zou, Yucheng
    Shi, Xiaobo
    Wang, Liping
    Zhao, Yusheng
    Wu, Sudong
    Gu, Meng
    ISCIENCE, 2021, 24 (12)
  • [49] Performance and Quality Comparison of Movie Alignment Software for Cryogenic Electron Microscopy
    Strelak, David
    Marchan, Daniel
    Carazo, Jose Maria
    Sorzano, Carlos O. S.
    MICROMACHINES, 2023, 14 (10)
  • [50] Comparison between MCNP and PENELOPE for the simulation of X-ray spectra in electron microscopy in the keV range
    Roet, D.
    Ceballos, C.
    Van Espen, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 251 (02): : 317 - 325