Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

被引:232
|
作者
McMullan, G. [1 ]
Faruqi, A. R. [1 ]
Clare, D. [2 ,3 ]
Henderson, R. [1 ]
机构
[1] MRC, Mol Biol Lab, Cambridge CB2 0QH, England
[2] Univ London, Birkbeck Coll, London WC1E 7HX, England
[3] Univ London, Birkbeck Coll, Inst Struct & Mol Biol, London WC1E 7HX, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
DQE; MTF; CMOS; NOISE TRANSFER; CCD CAMERAS; CRYO-EM; SIGNAL;
D O I
10.1016/j.ultramic.2014.08.002
中图分类号
TH742 [显微镜];
学科分类号
摘要
Low dose electron imaging applications such as electron cryo-microscopy are now benefit:Ling from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three defectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. (C) 2014 The Authors. Published by Elsevier B.V.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 50 条
  • [31] Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy
    Moser, Trevor
    Evans, James E. E.
    FRONTIERS IN NANOTECHNOLOGY, 2022, 4
  • [32] LOW-DOSE ELECTRON-MICROSCOPY FOR BIOLOGISTS - A PRACTICAL SYSTEM
    WRIGLEY, NG
    EUREM 88, VOLS 1-3: TUTORIALS, INSTRUMENTATION AND TECHNIQUES / PHYSICS AND MATERIALS / BIOLOGY, 1988, 93 : 313 - 318
  • [33] Modular software platform for low-dose electron microscopy and tomography
    Marsh, Michael P.
    Chang, Juan T.
    Booth, Christopher R.
    Liang, Nathan L.
    Schmid, Michael F.
    Chiu, Wah
    JOURNAL OF MICROSCOPY-OXFORD, 2007, 228 (03): : 384 - 389
  • [34] Noise suppression by active optics in low-dose electron microscopy
    Okamoto, Hiroshi
    APPLIED PHYSICS LETTERS, 2008, 92 (06)
  • [35] High speed/low dose analytical electron microscopy with dynamic sampling
    Hujsak, Karl A.
    Roth, Eric W.
    Kellogg, William
    Li, Yue
    Dravid, Vinayak P.
    MICRON, 2018, 108 : 31 - 40
  • [36] LOW-DOSE ELECTRON-MICROSCOPY FOR BIOLOGISTS - A PRACTICAL SYSTEM
    WRIGLEY, NG
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1988, (93): : 313 - 318
  • [37] LOW ELECTRON DOSE OBSERVATION FOR BIOLOGICAL MACROMOLECULES IN HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPY
    MITSUSHIMA, A
    YAMAGATA, N
    TANAKA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1991, 40 (04): : 292 - 292
  • [38] Use of low-temperature scanning electron microscopy to compare and characterize three classes of snow cover
    Foster, James
    Kelly, Richard
    Rango, Albert
    Armstrong, Richard
    Erbe, Eric F.
    Pooley, Christopher
    Wergin, William P.
    SCANNING, 2006, 28 (04) : 191 - 203
  • [39] New three dimensional simulator for low energy (∼1 keV) electron beam systems
    Lee, Y
    Lee, W
    Chun, K
    Kim, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1999, 17 (06): : 2903 - 2906
  • [40] Imaging nanosized gold colloids by atomic force microscopy: A direct comparison with transmission electron microscopy
    Mulvaney, P
    Giersig, M
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1996, 92 (17): : 3137 - 3143