Total Corneal Astigmatism Measurements: Agreement Between 2 Rotating Scheimpflug Cameras

被引:2
|
作者
Savini, Giacomo [1 ]
Noeser, Kristian [2 ]
Schiano-Lomoriello, Domenico [1 ]
Ducoli, Pietro [1 ]
机构
[1] Fdn GB Bietti, IRCCS, Via Livenza 3, I-00198 Rome, Italy
[2] Reg Hosp Randers, Dept Ophthalmol, Randers, Denmark
关键词
corneal astigmatism; Scheimpflug camera; vector analysis; TORIC INTRAOCULAR LENSES; POWER CALCULATION; CATARACT-SURGERY; REPEATABILITY; TOPOGRAPHY; REPRODUCIBILITY; TOMOGRAPHY; PENTACAM; SYSTEMS;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate agreement between rotating Scheimpflug camera (Pentacam HR, Oculus) and rotating Scheimpflug camera combined with Placido disc corneal topography (Sirius, CSO) in measuring total corneal astigmatism (TCA). Methods: In this observational study, all patients undergoing cataract surgery with preoperative measurement of TCA by both devices and a validated corneal topographer (Keratron, Optikon 2000) were retrospectively evaluated. Astigmatism analysis was performed with and without vector analysis separately in eyes with with-the-rule, against-the-rule, and oblique astigmatism. Vector analysis was performed using the Naeser polar system. Results: In 130 eyes of 130 subjects, nonvectorial analysis revealed that the mean TCA values obtained with the Sirius were higher than the corresponding values given by the Pentacam HR in all subgroups, although the difference was statistically significant only in eyes with against-the-rule astigmatism (P = 0.0009). This finding was confirmed by vector analysis. A TCA magnitude difference greater than 0.5 diopters was observed in 20.8% of cases, and a TCA axis difference greater than 10 degrees was observed in 45.4% of cases. Axis differences dropped to 18.5% when only eyes with astigmatism >0.75 diopters were analyzed and 3 measurements were averaged. The mean difference in the meridional and torsional power of TCA was close to zero in all subgroups, but with relatively large standard deviations (approximately 0.5 D). Conclusions: Agreement between both devices in measuring TCA is only moderate with respect to both magnitude and axis orientation.
引用
收藏
页码:463 / 469
页数:7
相关论文
共 50 条
  • [21] Anterior Surface-Based Keratometry Compared With Scheimpflug Tomography-Based Total Corneal Astigmatism
    Tonn, Bastian
    Klaproth, Oliver Klaus
    Kohnen, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) : 291 - 298
  • [22] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Bartolome, Francisco Perez
    Gonzalez, Rocio Vega
    Nieves, Jorge Peraza
    Moreno, Jose Maria Ruiz
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [23] Agreement between swept-source optical biometry and Scheimpflug-based topography measurements of posterior corneal curvature
    Kose, Bulent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 185 - 189
  • [24] Analysis of differences between keratometric astigmatism and total corneal astigmatism measured by IOLMaster 700C. Yu et al.Analysis of differences between keratometric astigmatism and total corneal astigmatism
    Chunxia Yu
    Xiaoling Fang
    Jinhua Tao
    Yiping Dong
    Shenyu Ben
    Yulan Wang
    International Ophthalmology, 45 (1)
  • [25] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Perez-Bartolome, Francisco
    Feu-Basilio, Silvia
    Rocha-de Lossada, Carlos
    Blanco-Dominguez, Irene
    Torras-Sanvicens, Josep
    Peraza-Nieves, Jorge
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3363 - 3371
  • [26] DIFFERENCES IN OCULAR RESIDUAL ASTIGMATISM FOR MEASUREMENTS OF ANTERIOR AND TOTAL CORNEAL POWER
    Greenwell, Timothy
    Zamora-Alejo, Katherine
    Athanasiov, Paul
    Goggin, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 55 - 56
  • [27] Agreement and reliability in measuring central corneal thickness with a rotating Scheimpflug-Placido system and ultrasound pachymetry
    Maresca, Nunzio
    Zeri, Fabrizio
    Palumbo, Paolo
    Calossi, Antonio
    CONTACT LENS & ANTERIOR EYE, 2014, 37 (06): : 442 - 446
  • [28] The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging
    Yune Zhao
    Ding Chen
    Giacomo Savini
    Qing Wang
    Hongfang Zhang
    Yili Jin
    Benhao Song
    Rui Ning
    Jinhai Huang
    Chenyang Mei
    Eye and Vision, 7
  • [29] Agreement Between Swept-source Optical Coherence Tomography and Rotating Scheimpflug Camera in Measurement of Corneal Parameters in Normal and Keratoconic Eyes
    Ghassemi, Hamed
    Zarei-Ghanavati, Mehran
    Khastavan, Mina
    Atighehchian, Mehrnaz
    Khorasani, Abbas Azimi
    Latifi, Golshan
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2023, 18 (04) : 386 - 395
  • [30] Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04): : 471 - 478