The principle and calibration of the third gear flow- meter

被引:3
|
作者
Zhang Jun [1 ]
Niu Meng-meng [1 ]
Tang Hong Mei [1 ]
Li Xian Hua [1 ]
Tang Cunren [1 ]
机构
[1] Anhui Univ Sci & Technol, Sch Mech Engn, Huainan 232001, Peoples R China
关键词
gear flow-meter; calibration experiment; pressure;
D O I
10.4028/www.scientific.net/AMM.397-400.1713
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15 similar to 0.2m(3)/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter.
引用
收藏
页码:1713 / 1717
页数:5
相关论文
共 50 条
  • [41] CALIBRATION OF THE NITROGEN METER
    LUNDGREN, N
    WHITE, CS
    BOOTHBY, WM
    FEDERATION PROCEEDINGS, 1952, 11 (01) : 98 - 98
  • [42] ON THE CALIBRATION OF A WIDEBAND METER
    Early, M. D.
    King, J. A. M.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 197 - 198
  • [43] STATIONARY TANGENTIAL GEAR TEETH METER
    SHAVER, LS
    MEASUREMENT TECHNIQUES-USSR, 1971, 14 (03): : 454 - &
  • [44] Using gear pumps to meter liquids
    Chances, S
    CHEMICAL PROCESSING, 2001, 64 (02): : 31 - 33
  • [45] Flow- and Reaction Processes in Model Flames.
    Knoche, K.F.
    Roertgen, H.
    Mueller, F.
    Fissan, H.J.
    Waerme, 1974, 80 (04): : 6 - 9
  • [46] Sensitivity Analysis of Factors Affecting the Calibration of Heat-Flow-Meter Apparatus
    Zarr, Robert R.
    Carvajal, Sergio A.
    Filliben, James J.
    JOURNAL OF TESTING AND EVALUATION, 2019, 47 (04) : 2979 - 3002
  • [47] A curve-fitting calibration method applied for ultrasonic flow-meter
    Luo, Yong
    Wang, Rangding
    Yao, Ling
    Telkomnika - Indonesian Journal of Electrical Engineering, 2013, 11 (10): : 5669 - 5674
  • [48] Flow meter calibration by volumetric method and by weighing method using an innovative system
    Yaibe, V.
    Aquino, M. H. G.
    Farias, E. C. C.
    Gabriel, P. C.
    3RD INTERNATIONAL CONGRESS ON MECHANICAL METROLOGY (CIMMEC2014), 2015, 648
  • [49] Calibration of the fiberoptical one-point flow meter characterized by spatial filtering
    Petrak, D
    Mahr, P
    TECHNISCHES MESSEN, 2000, 67 (11): : 474 - 478
  • [50] Calibration tests of pulse-Doppler flow meter at national standard loops
    Tezuka, Kenichi
    Mori, Michitsugu
    Suzuki, Takeshi
    Takeda, Yasushi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2008, 19 (3-4) : 181 - 187