The principle and calibration of the third gear flow- meter

被引:3
|
作者
Zhang Jun [1 ]
Niu Meng-meng [1 ]
Tang Hong Mei [1 ]
Li Xian Hua [1 ]
Tang Cunren [1 ]
机构
[1] Anhui Univ Sci & Technol, Sch Mech Engn, Huainan 232001, Peoples R China
关键词
gear flow-meter; calibration experiment; pressure;
D O I
10.4028/www.scientific.net/AMM.397-400.1713
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15 similar to 0.2m(3)/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter.
引用
收藏
页码:1713 / 1717
页数:5
相关论文
共 50 条
  • [31] Performance of a Gas Flow Meter Calibration System Utilizing Critical Flow Venturi Standards
    Carter, Michael
    Johansen, William
    Britton, Charles
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (03): : 247 - 254
  • [32] Rapid Flow- Based Peptide Synthesis
    Simon, Mark D.
    Heider, Patrick L.
    Adamo, Andrea
    Vinogradov, Alexander A.
    Mong, Surin K.
    Li, Xiyuan
    Berger, Tatiana
    Policarpo, Rocco L.
    Zhang, Chi
    Zou, Yekui
    Liao, Xiaoli
    Spokoyny, Alexander M.
    Jensen, Klavs F.
    Pentelute, Bradley L.
    CHEMBIOCHEM, 2014, 15 (05) : 713 - 720
  • [33] Simulation research for modelling the calibration of the flow meter with averaging pitot tube
    Gondek, Antoni
    Niezgoda-Zelasko, Beata
    Zelasko, Jerzy
    Inzynieria Chemiczna i Procesowa, 2002, 22 (04): : 633 - 644
  • [34] Secondary procedural error of flow meter calibration plants with multiposition benches
    V. A. Vlasov
    E. M. Zybin
    S. F. Levin
    N. V. Salunin
    Measurement Techniques, 2012, 55 : 366 - 370
  • [35] Simulation research for modelling the calibration of the flow meter with averaging pitot tube
    Gondek, A
    Niezgoda-Zelasko, B
    Zelasko, J
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (04): : 633 - 644
  • [36] Construction and calibration of a large-area heat flow meter apparatus
    Yang, Inseok
    Kim, Daeho
    Lee, Sanghyun
    Jang, Hyunmin
    ENERGY AND BUILDINGS, 2019, 203
  • [37] Secondary procedural error of flow meter calibration plants with multiposition benches
    Vlasov, V. A.
    Zybin, E. M.
    Levin, S. F.
    Salunin, N. V.
    MEASUREMENT TECHNIQUES, 2012, 55 (03) : 366 - 370
  • [38] CALIBRATION OF FLOW-RATE IN HEADBOX MANIFOLD TUBES BY ULTRASONIC METER
    HARKONEN, E
    KARRAS, M
    PAPERI JA PUU-PAPER AND TIMBER, 1987, 69 (06): : 506 - 508
  • [39] Calibration of an electrostatic flow meter for bulk solids measurement in pneumatic transportation
    University of Teeside, School of Science and Technology, Middlesbrough TS1 3BA, United Kingdom
    Bulk Solid Handl, 2008, 5 (314-319): : 314 - 319
  • [40] ANALYTICAL PROCEDURE OF CALIBRATION FOR THE PULSED ULTRASONIC DOPPLER FLOW METER.
    Jorgensen, J.E.
    Garbini, J.L.
    American Society of Mechanical Engineers (Paper), 1973, (73 -WA/Bio-1):