The principle and calibration of the third gear flow- meter

被引:3
|
作者
Zhang Jun [1 ]
Niu Meng-meng [1 ]
Tang Hong Mei [1 ]
Li Xian Hua [1 ]
Tang Cunren [1 ]
机构
[1] Anhui Univ Sci & Technol, Sch Mech Engn, Huainan 232001, Peoples R China
关键词
gear flow-meter; calibration experiment; pressure;
D O I
10.4028/www.scientific.net/AMM.397-400.1713
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15 similar to 0.2m(3)/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter.
引用
收藏
页码:1713 / 1717
页数:5
相关论文
共 50 条
  • [1] Water flow meter calibration with a master meter method
    Sejong Chun
    Byung-Ro Yoon
    Hae-Man Choi
    Yong Bong Lee
    International Journal of Precision Engineering and Manufacturing, 2017, 18 : 1075 - 1083
  • [2] Water flow meter calibration with a master meter method
    Chun, Sejong
    Yoon, Byung-Ro
    Choi, Hae-Man
    Lee, Yong Bong
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2017, 18 (08) : 1075 - 1083
  • [3] FLOW METER CALIBRATION BY ELECTRONIC WEIGHING
    TEIJEMA, J
    CME-CHARTERED MECHANICAL ENGINEER, 1978, 25 (02): : 40 - 41
  • [4] Calibration of a heat flow meter apparatus
    Lackey, John
    Normandin, Nicole
    Marchand, Roger
    Kumaran, Kumar
    Journal of thermal insulation and building envelopes, 1994, 18 : 128 - 144
  • [5] The Calibration System of Gas Flow meter Based on Standard Flow meter Method
    Ma Wentao
    Sun Bin
    AUTOMATION EQUIPMENT AND SYSTEMS, PTS 1-4, 2012, 468-471 : 3122 - 3125
  • [6] Instantaneous Flow Characteristics for General Gear Flow-meter
    Jun, Zhang
    Bin, Zhang
    Yi, Li
    2011 AASRI CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INDUSTRY APPLICATION (AASRI-AIIA 2011), VOL 2, 2011, : 144 - 147
  • [7] Instantaneous Flow Characteristics for General Gear Flow-meter
    Jun, Zhang
    Teng, Zhang
    Zhang, Cheng
    Juan, Tao
    ADVANCED COMPOSITE MATERIALS, PTS 1-3, 2012, 482-484 : 1990 - 1994
  • [8] DATA ACQUISITION WITH DYNAMIC FLOW OF GEAR FLOW METER BASED ON LABVIEW
    Zhang, Jun
    Hu, Yuan-Shun
    Tang, Hong-Mei
    ENERGY, ENVIRONMENTAL & SUSTAINABLE ECOSYSTEM DEVELOPMENT, 2016,
  • [9] CALIBRATION OF FLOW METER USING INTEGRAL METHODS
    VARENE, P
    SAUMON, G
    VIEILLEFOND, H
    JOURNAL DE PHYSIOLOGIE, 1971, 63 (02): : A104 - +
  • [10] Calibration of a designed and implemented ultrasonic flow meter
    Iskender, Ires
    Ertaş, Emre
    Genç, Naci