Nineteen-Channel Receive Array and Four-Channel Transmit Array Coil for Cervical Spinal Cord Imaging at 7T

被引:55
|
作者
Zhao, Wei [1 ,2 ]
Cohen-Adad, Julien [3 ]
Polimeni, Jonathan R. [1 ,2 ]
Keil, Boris [1 ,2 ]
Guerin, Bastien [1 ,2 ]
Setsompop, Kawin [1 ,2 ]
Serano, Peter [1 ,2 ]
Mareyam, Azma [1 ,2 ]
Hoecht, Philipp [4 ]
Wald, Lawrence L. [1 ,2 ,5 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Ecole Polytech, Dept Elect Engn, Montreal, PQ H3C 3A7, Canada
[4] Siemens AG, Healthcare Sect, Magnet Resonance, Erlangen, Germany
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
high-field MRI; RF coil; transmit array; receive array; cervical spinal cord MRI; MULTIPLE-SCLEROSIS; RF COIL; MRI; LESIONS; DESIGN; BRAIN; NMR;
D O I
10.1002/mrm.24911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and validate a radiofrequency (RF) array coil for cervical spinal cord imaging at 7T. Methods: A 19-channel receive array with a four-channel transmit array was developed on a close-fitting coil former at 7T. Transmit efficiency and specific absorption rate were evaluated in a B-1(+) mapping study and an electromagnetic model. Receive signal-to-noise ratio (SNR) and noise amplification for parallel imaging were evaluated and compared with a commercial 3T 19-channel head-neck array and a 7T four-channel spine array. The performance of the array was qualitatively demonstrated in human volunteers using high-resolution imaging (down to 300 mm in-plane). Results: The transmit and receive arrays showed good bench performance. The SNR was approximately 4.2-fold higher in the 7T receive array at the location of the cord with respect to the 3T coil. The g-factor results showed an additional acceleration was possible with the 7T array. In vivo imaging was feasible and showed high SNR and tissue contrast. Conclusion: The highly parallel transmit and receive arrays were demonstrated to be fit for spinal cord imaging at 7T. The high sensitivity of the receive coil combined with ultra-high field will likely improve investigations of microstructure and tissue segmentation in the healthy and pathological spinal cord. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [31] Sodium imaging of human brain at 7 T with 15-channel array coil
    Qian, Yongxian
    Zhao, Tiejun
    Wiggins, Graham C.
    Wald, Lawrence L.
    Zheng, Hai
    Weimer, Jonathan
    Boada, Fernando E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) : 1808 - 1814
  • [32] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Xinqiang Yan
    Xiaoliang Zhang
    Long Wei
    Rong Xue
    Applied Magnetic Resonance, 2015, 46 : 59 - 66
  • [33] A human cerebral and cerebellar 8-channel transceive RF dipole coil array at 7T
    Clement, Jeremie D.
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1447 - 1458
  • [34] Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T
    Yan, Xinqiang
    Zhang, Xiaoliang
    Wei, Long
    Xue, Rong
    APPLIED MAGNETIC RESONANCE, 2015, 46 (01) : 59 - 66
  • [35] Influence of Shield Distance on RF Transmit Performance for a 7T Multi-channel MRI Loop Array
    Kozlov, M.
    Turner, R.
    PROCEEDINGS OF PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2012), 2012, : 255 - 259
  • [36] Four-Channel Surface Coil Array for 300-MHz Pulsed EPR Imaging: Proof-of-Concept Experiments
    Enomoto, Ayano
    Hirata, Hiroshi
    Matsumoto, Shingo
    Saito, Keita
    Subramanian, Sankaran
    Krishna, Murali C.
    Devasahayam, Nallathamby
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 853 - 858
  • [37] A Flexible 32-channel Receive Array Combined With a Homogeneous Transmit Coil for Human Lung Imaging With Hyperpolarized 3He at 1.5 T
    Deppe, Martin H.
    Parra-Robles, Juan
    Marshall, Helen
    Lanz, Titus
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1788 - 1797
  • [38] A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T
    Wilcox, Matthew
    Ogier, Stephen
    Cheshkov, Sergey
    Dimitrov, Ivan
    Malloy, Craig
    Wright, Steven
    McDougall, Mary
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (06) : 2036 - 2046
  • [39] A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla
    May, Markus W.
    Hansen, Sam-Luca J. D.
    Mahmutovic, Mirsad
    Scholz, Alina
    Kutscha, Nicolas
    Guerin, Bastien
    Stockmann, Jason P.
    Barry, Robert L.
    Kazemivalipour, Ehsan
    Gumbrecht, Rene
    Kimmlingen, Ralph
    Adriany, Markus
    Chang, Yulin
    Triantafyllou, Christina
    Knake, Susanne
    Wald, Lawrence L.
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (03) : 1419 - 1433
  • [40] An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T
    Kraff, Oliver
    Bitz, Andreas K.
    Kruszona, Stefan
    Orzada, Stephan
    Schaefer, Lena C.
    Theysohn, Jens M.
    Maderwald, Stefan
    Ladd, Mark E.
    Quick, Harald H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 734 - 740