Four-Channel Surface Coil Array for 300-MHz Pulsed EPR Imaging: Proof-of-Concept Experiments

被引:8
|
作者
Enomoto, Ayano [1 ]
Hirata, Hiroshi [1 ]
Matsumoto, Shingo [2 ]
Saito, Keita [2 ]
Subramanian, Sankaran [2 ]
Krishna, Murali C. [2 ]
Devasahayam, Nallathamby [2 ]
机构
[1] Hokkaido Univ, Grad Sch Informat Sci & Technol, Div Bioengn & Bioinformat, Sapporo, Hokkaido, Japan
[2] NCI, Radiat Biol Branch, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
基金
日本学术振兴会;
关键词
FT-EPR imaging; surface coil array; Oxo63; single point imaging; in vivo imaging; TUMOR HYPOXIA; SPIN-ECHO; RESONANCE; SPECTROSCOPY; ACQUISITION; RESOLUTION; SCAN;
D O I
10.1002/mrm.24702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Time-domain electron paramagnetic resonance imaging is currently a useful preclinical molecular imaging modality in experimental animals such as mice and is capable of quantitatively mapping hypoxia in tumor implants. The microseconds range relaxation times (T-1 and T-2) of paramagnetic tracers and the large bandwidths (tens of MHz) to be excited by electron paramagnetic resonance pulses for spatial encoding makes imaging of large objects a challenging task. The possibility of using multiple array coils to permit studies on large sized object is the purpose of the present work. Toward this end, the use of planar array coils in different configurations to image larger objects than cannot be fully covered by a single resonator element is explored. Multiple circular surface coils, which are arranged in a plane or at suitable angles mimicking a volume resonator, are used in imaging a phantom and a tumor-bearing mouse leg. The image was formed by combining the images collected from the individual coils with suitable scaling. The results support such a possibility. By multiplexing or interleaving the measurements from each element of such array resonators, one can scale up the size of the subject and at the same time reduce the radiofrequency power requirements and increase the sensitivity. Magn Reson Med 71:853-858, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:853 / 858
页数:6
相关论文
共 9 条
  • [1] Passive Decoupling Due to Low Q-Factors of Four-Channel Coils in 300-MHz Pulsed EPR Imaging
    Enomoto, Ayano
    Saito, Keita
    Subramanian, Sankaran
    Krishna, Murali C.
    Hirata, Hiroshi
    Devasahayam, Nallathamby
    APPLIED MAGNETIC RESONANCE, 2015, 46 (06) : 671 - 683
  • [2] Passive Decoupling Due to Low Q-Factors of Four-Channel Coils in 300-MHz Pulsed EPR Imaging
    Ayano Enomoto
    Keita Saito
    Sankaran Subramanian
    Murali C. Krishna
    Hiroshi Hirata
    Nallathamby Devasahayam
    Applied Magnetic Resonance, 2015, 46 : 671 - 683
  • [3] Four-channel surface coil array for sequential CW-EPR image acquisition
    Enomoto, Ayano
    Emoto, Miho
    Fujii, Hirotada
    Hirata, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE, 2013, 234 : 21 - 29
  • [4] Parallel image-acquisition in continuous-wave electron paramagnetic resonance imaging with a surface coil array: Proof-of-concept experiments
    Enomoto, Ayano
    Hirata, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE, 2014, 239 : 29 - 33
  • [5] Sodium imaging of the heart at 7T: design, evaluation and application of a four-channel transmit/receive surface coil array
    A Graessl
    A Ruehle
    W Renz
    L Winter
    H Pfeiffer
    J Ruff
    J Rieger
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [6] Nineteen-Channel Receive Array and Four-Channel Transmit Array Coil for Cervical Spinal Cord Imaging at 7T
    Zhao, Wei
    Cohen-Adad, Julien
    Polimeni, Jonathan R.
    Keil, Boris
    Guerin, Bastien
    Setsompop, Kawin
    Serano, Peter
    Mareyam, Azma
    Hoecht, Philipp
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 291 - 300
  • [7] An embedded four-channel receive-only RF coil array for fMRI experiments of the somatosensory pathway in conscious awake marmosets
    Papoti, Daniel
    Yen, Cecil Chern-Chyi
    Mackel, Julie B.
    Merkle, Hellmut
    Silva, Afonso C.
    NMR IN BIOMEDICINE, 2013, 26 (11) : 1395 - 1402
  • [8] Design and Application of a Four-Channel Transmit/Receive Surface Coil for Functional Cardiac Imaging at 7T
    Dieringer, Matthias A.
    Renz, Wolfgang
    Lindel, Tomasz
    Seifert, Frank
    Frauenrath, Tobias
    von Knobelsdorff-Brenkenhoff, Florian
    Waiczies, Helmar
    Hoffmann, Werner
    Rieger, Jan
    Pfeiffer, Harald
    Ittermann, Bernd
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 736 - 741
  • [9] Design of a Four-Channel Surface Receiver Coil Array Without Preamplifiers for the Decoupling Between Elements: Validation for High-Resolution Rat Knee MR Imaging
    Perrier, Anne-Laure
    Goebel, Jean-Christophe
    Pinzano-Watrin, Astrid
    Roeder, Emilie
    Gillet, Pierre
    Grenier, Denis
    Beuf, Olivier
    IEEE SENSORS JOURNAL, 2013, 13 (06) : 2450 - 2458