Nineteen-Channel Receive Array and Four-Channel Transmit Array Coil for Cervical Spinal Cord Imaging at 7T

被引:55
|
作者
Zhao, Wei [1 ,2 ]
Cohen-Adad, Julien [3 ]
Polimeni, Jonathan R. [1 ,2 ]
Keil, Boris [1 ,2 ]
Guerin, Bastien [1 ,2 ]
Setsompop, Kawin [1 ,2 ]
Serano, Peter [1 ,2 ]
Mareyam, Azma [1 ,2 ]
Hoecht, Philipp [4 ]
Wald, Lawrence L. [1 ,2 ,5 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Ecole Polytech, Dept Elect Engn, Montreal, PQ H3C 3A7, Canada
[4] Siemens AG, Healthcare Sect, Magnet Resonance, Erlangen, Germany
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
high-field MRI; RF coil; transmit array; receive array; cervical spinal cord MRI; MULTIPLE-SCLEROSIS; RF COIL; MRI; LESIONS; DESIGN; BRAIN; NMR;
D O I
10.1002/mrm.24911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and validate a radiofrequency (RF) array coil for cervical spinal cord imaging at 7T. Methods: A 19-channel receive array with a four-channel transmit array was developed on a close-fitting coil former at 7T. Transmit efficiency and specific absorption rate were evaluated in a B-1(+) mapping study and an electromagnetic model. Receive signal-to-noise ratio (SNR) and noise amplification for parallel imaging were evaluated and compared with a commercial 3T 19-channel head-neck array and a 7T four-channel spine array. The performance of the array was qualitatively demonstrated in human volunteers using high-resolution imaging (down to 300 mm in-plane). Results: The transmit and receive arrays showed good bench performance. The SNR was approximately 4.2-fold higher in the 7T receive array at the location of the cord with respect to the 3T coil. The g-factor results showed an additional acceleration was possible with the 7T array. In vivo imaging was feasible and showed high SNR and tissue contrast. Conclusion: The highly parallel transmit and receive arrays were demonstrated to be fit for spinal cord imaging at 7T. The high sensitivity of the receive coil combined with ultra-high field will likely improve investigations of microstructure and tissue segmentation in the healthy and pathological spinal cord. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [1] Sodium imaging of the heart at 7T: design, evaluation and application of a four-channel transmit/receive surface coil array
    A Graessl
    A Ruehle
    W Renz
    L Winter
    H Pfeiffer
    J Ruff
    J Rieger
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [2] Design and Application of a Four-Channel Transmit/Receive Surface Coil for Functional Cardiac Imaging at 7T
    Dieringer, Matthias A.
    Renz, Wolfgang
    Lindel, Tomasz
    Seifert, Frank
    Frauenrath, Tobias
    von Knobelsdorff-Brenkenhoff, Florian
    Waiczies, Helmar
    Hoffmann, Werner
    Rieger, Jan
    Pfeiffer, Harald
    Ittermann, Bernd
    Schulz-Menger, Jeanette
    Niendorf, Thoralf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (03) : 736 - 741
  • [3] A Four-Channel Broadband MRI Receive Array Coil
    Hou, Jue
    Bauer, Courtney C.
    Sun, Chenhao
    Malone, Ben
    Griffin, Jay
    Wright, Steven M.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [4] A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T
    Del Bosque, Romina
    Cui, Jiaming
    Ogier, Stephen
    Cheshkov, Sergey
    Dimitrov, Ivan E.
    Malloy, Craig
    Wright, Steven M.
    McDougall, Mary
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 551 - 559
  • [5] 12-channel receive array with a volume transmit coil for hand/wrist imaging at 7 T
    Raghuraman, Sairamesh
    Mueller, Matthias F.
    Zbyn, Stefan
    Baer, Peter
    Breuer, Felix A.
    Friedrich, Klaus M.
    Trattnig, Siegfried
    Lanz, Titus
    Jakob, Peter M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) : 238 - 244
  • [6] Design, evaluation and application of a modular 32 channel transmit/receive surface coil array for cardiac MRI at 7T
    A Graessl
    W Renz
    F Hezel
    H Pfeiffer
    W Hoffmann
    P Kellman
    T Niendorf
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [7] 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array
    Rietsch, Stefan H. G.
    Orzada, Stephan
    Maderwald, Stefan
    Brunheim, Sascha
    Philips, Bart W. J.
    Scheenen, Tom W. J.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2018, 45 (07) : 2978 - 2990
  • [8] Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging
    Brown, Ryan
    Madelin, Guillaume
    Lattanzi, Riccardo
    Chang, Gregory
    Regatte, Ravinder R.
    Sodickson, Daniel K.
    Wiggins, Graham C.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 259 - 268
  • [9] A combined 32-channel receive-loops/8-channel transmit-dipoles coil array for whole-brain MR imaging at 7T
    Clement, Jeremie
    Gruetter, Rolf
    Ipek, Ozlem
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1229 - 1241
  • [10] Eight-channel decoupled array for cervical spinal cord imaging at 3T: six-channel posterior and two-channel anterior array coil
    Sapkota, Nabraj
    Thapa, Bijaya
    Lee, YouJung
    Kim, Taeho
    Bisson, Erica F.
    Shah, Lubdha M.
    Rose, John W.
    Jeong, Eun-Kee
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (02) : 90 - 99