Nineteen-Channel Receive Array and Four-Channel Transmit Array Coil for Cervical Spinal Cord Imaging at 7T

被引:55
|
作者
Zhao, Wei [1 ,2 ]
Cohen-Adad, Julien [3 ]
Polimeni, Jonathan R. [1 ,2 ]
Keil, Boris [1 ,2 ]
Guerin, Bastien [1 ,2 ]
Setsompop, Kawin [1 ,2 ]
Serano, Peter [1 ,2 ]
Mareyam, Azma [1 ,2 ]
Hoecht, Philipp [4 ]
Wald, Lawrence L. [1 ,2 ,5 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Ecole Polytech, Dept Elect Engn, Montreal, PQ H3C 3A7, Canada
[4] Siemens AG, Healthcare Sect, Magnet Resonance, Erlangen, Germany
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
high-field MRI; RF coil; transmit array; receive array; cervical spinal cord MRI; MULTIPLE-SCLEROSIS; RF COIL; MRI; LESIONS; DESIGN; BRAIN; NMR;
D O I
10.1002/mrm.24911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and validate a radiofrequency (RF) array coil for cervical spinal cord imaging at 7T. Methods: A 19-channel receive array with a four-channel transmit array was developed on a close-fitting coil former at 7T. Transmit efficiency and specific absorption rate were evaluated in a B-1(+) mapping study and an electromagnetic model. Receive signal-to-noise ratio (SNR) and noise amplification for parallel imaging were evaluated and compared with a commercial 3T 19-channel head-neck array and a 7T four-channel spine array. The performance of the array was qualitatively demonstrated in human volunteers using high-resolution imaging (down to 300 mm in-plane). Results: The transmit and receive arrays showed good bench performance. The SNR was approximately 4.2-fold higher in the 7T receive array at the location of the cord with respect to the 3T coil. The g-factor results showed an additional acceleration was possible with the 7T array. In vivo imaging was feasible and showed high SNR and tissue contrast. Conclusion: The highly parallel transmit and receive arrays were demonstrated to be fit for spinal cord imaging at 7T. The high sensitivity of the receive coil combined with ultra-high field will likely improve investigations of microstructure and tissue segmentation in the healthy and pathological spinal cord. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:291 / 300
页数:10
相关论文
共 50 条
  • [41] Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging
    Wiggins, GC
    Potthast, A
    Triantafyllou, C
    Wiggins, CJ
    Wald, LL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 235 - 240
  • [42] Cardiac gating using scattering of an 8-channel parallel transmit coil at 7T
    Jaeschke, Sven H. F.
    Robson, Matthew D.
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 633 - 640
  • [43] An eight-channel transmit/receive array of TE01 mode high permittivity ceramic resonators for human imaging at 7 T
    Aussenhofer, S. A.
    Webb, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 243 : 122 - 129
  • [44] A nine-channel transmit/receive array for spine imaging at 10.5 T: Introduction to a nonuniform dielectric substrate antenna
    Sadeghi-Tarakameh, Alireza
    Jungst, Steve
    Lanagan, Mike
    DelaBarre, Lance
    Wu, Xiaoping
    Adriany, Gregor
    Metzger, Gregory J.
    Van de Moortele, Pierre-Francois
    Ugurbil, Kamil
    Atalar, Ergin
    Eryaman, Yigitcan
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 2074 - 2088
  • [45] Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T
    Valkovic, Ladislav
    Dragonu, Iulius
    Almujayyaz, Salam
    Batzakis, Alex
    Young, Liam A. J.
    Purvis, Lucian A. B.
    Clarke, William T.
    Wichmann, Tobias
    Lanz, Titus
    Neubauer, Stefan
    Robson, Matthew D.
    Klomp, Dennis W. J.
    Rodgers, Christopher T.
    PLOS ONE, 2017, 12 (10):
  • [46] 32-channel phased-array receive with asymmetric birdcage transmit coil for hyperpolarized xenon-129 lung imaging
    Dregely, Isabel
    Ruset, Iulian C.
    Wiggins, Graham
    Mareyam, Azma
    Mugler, John P., III
    Altes, Talissa A.
    Meyer, Craig
    Ruppert, Kai
    Wald, Lawrence L.
    Hersman, F. William
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) : 576 - 583
  • [47] A 16-Channel Dual-Row Transmit Array in Combination with a 31-Element Receive Array for Human Brain Imaging at 9.4 T
    Shajan, G.
    Kozlov, Mikhail
    Hoffmann, Jens
    Turner, Robert
    Scheffler, Klaus
    Pohmann, Rolf
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 870 - 879
  • [48] Simultaneous whole-brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8-channel transceiver array and 56-channel receiver array
    Baskaran, Divya
    Ding, Belinda
    Chu, Son
    Mcelhinney, Paul
    Allwood-Spiers, Sarah
    Williams, Sydney N.
    Muir, Keith
    Fullerton, Natasha Eileen
    Porter, David Andrew
    Gunamony, Shajan
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [49] Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis at 7T
    Dula, Adrienne N.
    Pawate, Siddharama
    Dortch, Richard D.
    Barry, Robert L.
    George-Durrett, Kristen M.
    Lyttle, Bailey D.
    Dethrage, Lindsey M.
    Gore, John C.
    Smith, Seth A.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 (03) : 320 - 328
  • [50] A 32-Channel Lattice Transmission Line Array for Parallel Transmit and Receive MRI at 7 Tesla
    Adriany, Gregor
    Auerbach, Edward J.
    Snyder, Carl J.
    Gozubuyuk, Ark
    Moeller, Steen
    Ritter, Johannes
    Van de Moortele, Pierre-Francois
    Vaughan, Tommy
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1478 - 1485