The syringe potentiometer: a low-cost device for pneumotachograph calibration

被引:4
|
作者
Cross, Troy J. [1 ,2 ]
Kelley, Eli F. [1 ]
Hardy, Tim A. [3 ]
Isautier, Jennifer M. J. [1 ]
Johnson, Bruce D. [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55902 USA
[2] Griffith Univ, Menzies Hlth Inst Queensland, Brisbane, Qld, Australia
[3] Univ Leeds, Sch Biomed Sci, Leeds, W Yorkshire, England
关键词
calibration; pneumotachograph; potentiometer; respiratory airflow; syringe; ACCURACY;
D O I
10.1152/japplphysiol.00150.2019
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this report was to 1) detail the construction of a low-cost device that provides a "reference" flow waveform for pneumotachograph (PNT) calibration, i.e., the "syringe potentiometer" (SP), and to compare the 2) accuracy and 3) practical performance of "calibration curves" obtained with the SP device to other more established methods of PNT calibration, i.e., the weighted averaging (WA) and polynomial least-squares (PolyLS) methods. Volume and flow waveforms obtained via the SP device were validated against a motion capture system and were deemed accurate surrogates of actual syringe volume and flows. The SP device was used to construct a calibration curve of a PNT by dividing the flow waveform of the SP by the analog output of the PNT amplifier. A total of 187 inspiratory and 187 expiratory strokes were collected. When the entire data set of expiratory strokes was used, the SP, WA, and PolyLS methods together demonstrated acceptable volume and flow errors as per American Thoracic Society/European Respiratory Society recommendations (less than +/- 3.5% and less than +/- 5.0% errors, respectively). The "practical" performance of each method was assessed with a nested subsampling procedure, whereby volume and flow errors were evaluated as the number of strokes was increased (in blocks of 5 strokes). To this end, the SP method demonstrated practical performance superior to that of the WA and PolyLS approaches, whereby acceptable volume and flow errors were achieved after only 5 calibration strokes; the WA and PolyLS methods required 15 and 20 strokes, respectively, to achieve the same level of volume and flow accuracy. NEW & NOTEWORTHY This report describes the construction and validation of a low-cost device for the purposes of pneumotachograph (PNT) calibration: the "syringe potentiometer" (SP). Calibration of a PNT with the SP device yielded acceptable volume and flow errors (<3.5% and 5%, respectively) across a wide range of flows (<0.5 to 15 L/s). The SP device offered superior "practical performance" over other established PNT calibration methods, whereby acceptable volume and flow errors were achieved after only five calibration strokes.
引用
收藏
页码:1150 / 1162
页数:13
相关论文
共 50 条
  • [41] A low-cost device for automatic photometric titrations
    Rocha, FRP
    Reis, BF
    JOURNAL OF CHEMICAL EDUCATION, 2000, 77 (02) : 258 - 261
  • [42] Low-cost device for ratiometric fluorescence measurements
    Kostov, Y
    Rao, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12): : 4466 - 4470
  • [43] Low-cost Managed Digital Signage System with Signage Device using Small-sized and Low-cost Information Device
    Mishima, Kazuhiro
    Sakurada, Takeshi
    Hagiwara, Yoichi
    2017 14TH IEEE ANNUAL CONSUMER COMMUNICATIONS & NETWORKING CONFERENCE (CCNC), 2017, : 573 - 575
  • [44] A low-cost monocular vision system for robot calibration
    Rojas Urzulo, Jesus Abraham
    Gonzalez-Barbosa, Jose-Joel
    Sandoval Castro, Xochitl Yamile
    Ruiz Torres, Maximiano Francisco
    Gonzalez-Barbosa, Erick-Alejandro
    NEXO REVISTA CIENTIFICA, 2023, 36 (04): : 482 - 494
  • [45] Calibration verification of a low-cost method for MEMS accelerometers
    Parsi, B.
    Bahrami, M.
    Esfahani, A. Monemian
    Sany, B. Seyedzadeh
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2014, 36 (05) : 579 - 587
  • [46] A Method of A Method of Low-Cost IMU Calibration and Alignment
    Lv, Jixin
    Ravankar, Ankit A.
    Kobayashi, Yukinori
    Emaru, Takanori
    2016 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2016, : 373 - 378
  • [47] Evaluation of Low-cost AirQuality Sensor Calibration Models
    Aula, Kasimir
    Lagerspetz, Eemil
    Nurmi, Petteri
    Tarkoma, Sasu
    ACM TRANSACTIONS ON SENSOR NETWORKS, 2022, 18 (04)
  • [48] On Calibration of a Low-Cost Time-of-Flight Camera
    Kuznetsova, Alina
    Rosenhahn, Bodo
    COMPUTER VISION - ECCV 2014 WORKSHOPS, PT I, 2015, 8925 : 415 - 427
  • [49] Development and calibration of a low-cost didactic thermal plant
    Oliveira, Andressa M.
    Pinheiro Filho, Jose C.
    Braga, Glauber A.
    Vasconcellos, Eduardo M. M.
    Silva, Luis F., V
    Araujo, I
    Brito, Davi B.
    2019 IEEE CHILEAN CONFERENCE ON ELECTRICAL, ELECTRONICS ENGINEERING, INFORMATION AND COMMUNICATION TECHNOLOGIES (CHILECON), 2019,
  • [50] EEATC: A Novel Calibration Approach for Low-Cost Sensors
    Narayana, M. V.
    Jalihal, Devendra
    Nagendra, S. M. Shiva
    IEEE SENSORS JOURNAL, 2023, 23 (19) : 23500 - 23511