Lower Tear Meniscus Height Measurements Using Keratography and Swept-Source Optical Coherence Tomography and Effect of Fluorescein Instillation Methods

被引:10
|
作者
Lam, Andrew K. C. [1 ]
Tai, Shirley K. Y. [1 ]
Chan, Jacky K. T. [1 ]
Ng, Raymond W. E. [1 ]
机构
[1] Hong Kong Polytech Univ, Sch Optometry, Lab Expt Optometry, Hong Kong, Peoples R China
关键词
Tear meniscus height; keratography; swept-source optical coherence tomography; bulbar conjunctiva; palpebral conjunctiva; DRY EYE; PREVALENCE; DYNAMICS; VOLUME;
D O I
10.1080/02713683.2019.1629598
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The first aim of this study was to compare inferior tear meniscus height (TMH) measured by keratography and swept-source optical coherence tomography (OCT). Effect of locations of fluorescein instillation and subjects' subjective sensation, and the TMH results were also investigated. Methods: Forty-one eyes from 41 healthy adults had TMH randomly measured by keratography (K5M, Oculus, Germany) and swept-source OCT (Casia SS-1000, Tomey Corp, Japan) at baseline, followed by touching either the inferior bulbar or inferior palpebral conjunctiva, randomly assigned, with a moistened fluorescein strip. Two-way analysis of variance (ANOVA) was used to compare TMH obtained from the two devices and three measurement conditions. Subjective sensation of conjunctival touch was obtained through a 4-point scale with zero representing no sensation, and one to three representing ocular sensation in an ascending order. Results: Two-way ANOVA revealed no significant difference in TMH between keratography and swept-source OCT (Factor (devices): F = 0.579, p = .451) while there was a significant difference among fluorescein instillations (Factor (conditions): F = 10.146, p < .001). Baseline TMH was around 0.25 mm, and increased to around 0.28 mm after instillation of fluorescein sodium. Ocular sensation was similar between the two conjunctival touch, and TMH was not significantly associated with ocular sensation. Conclusions: Keratography and swept-source OCT provided similar TMH results. Applying fluorescein sodium through moistened fluorescein strip could over-estimate TMH by around 0.03 mm. Applying moistened fluorescein strip at bulbar or palpebral conjunctival led to similar subjective sensations and did not affect TMH measurement.
引用
收藏
页码:1203 / 1208
页数:6
相关论文
共 50 条
  • [41] Swept-source optical coherence tomography angiography in toxoplasmic retinochoroiditis
    Doukh, Meryem
    Ksiaa, Imen
    Ben Amor, Hager
    Abroug, Nesrine
    Jelliti, Bechir
    Khochteli, Sana
    Khairallah, Moncef
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [42] Images of Arterial Tissues Using Catheter Swept-Source Optical Coherence Tomography
    Mao, Youxin
    Flueraru, Costel
    Chang, Shoude
    Popescu, Dan P.
    Sowa, M. G.
    PHOTONICS NORTH 2010, 2010, 7750
  • [43] Swept-Source Optical Coherence Tomography Features of Choroidal Nevi
    Francis, Jasmine H.
    Pang, Claudine E.
    Abramson, David H.
    Milman, Tatyana
    Folberg, Robert
    Mrejen, Sarah
    Freund, K. Bailey
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 169 - 176
  • [44] Swept-Source Optical Coherence Tomography-Supervised Biopsy
    Xu, Qiuyun
    Adabi, Saba
    Clayton, Anne
    Daveluy, Steven
    Mehregan, Darius
    Nasiriavanaki, Mohammadreza
    DERMATOLOGIC SURGERY, 2018, 44 (06) : 768 - 775
  • [45] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING OF THE CHORIOCAPILLARIS
    Ledesma-Gil, Gerardo
    Fernandez-Avellaneda, Pedro
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (07): : 1373 - 1378
  • [46] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [47] En face features of polypoidalchoroidalvasculopathy using swept-source optical coherence tomography
    Won, Moon Sang
    Lee, Byung Ro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [48] Defect inspection of actuator lenses using swept-source optical coherence tomography
    Lee, Jaeyul
    Shirazi, Muhammad Faizan
    Park, Kibeom
    Jeon, Mansik
    Kim, Jeehyun
    OPTICAL REVIEW, 2018, 25 (03) : 403 - 409
  • [49] Evaluation of choroidal lesions with swept-source optical coherence tomography
    Ung, Cindy
    Lains, Ines
    Silverman, Rebecca F.
    Woods, Russell
    Lane, Anne Marie
    Papakostas, Thanos D.
    Husain, Deeba
    Miller, Joan W.
    Gragoudas, Evangelos S.
    Kim, Ivana K.
    Miller, John B.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (01) : 88 - 93
  • [50] Speckle variance detection of microvasculature using swept-source optical coherence tomography
    Mariampillai, Adrian
    Standish, Beau A.
    Moriyama, Eduardo H.
    Khurana, Mamta
    Munce, Nigel R.
    Leung, Michael K. K.
    Jiang, James
    Cable, Alex
    Wilson, Brian C.
    Vitkin, I. Alex
    Yang, Victor X. D.
    OPTICS LETTERS, 2008, 33 (13) : 1530 - 1532