Lower Tear Meniscus Height Measurements Using Keratography and Swept-Source Optical Coherence Tomography and Effect of Fluorescein Instillation Methods

被引:10
|
作者
Lam, Andrew K. C. [1 ]
Tai, Shirley K. Y. [1 ]
Chan, Jacky K. T. [1 ]
Ng, Raymond W. E. [1 ]
机构
[1] Hong Kong Polytech Univ, Sch Optometry, Lab Expt Optometry, Hong Kong, Peoples R China
关键词
Tear meniscus height; keratography; swept-source optical coherence tomography; bulbar conjunctiva; palpebral conjunctiva; DRY EYE; PREVALENCE; DYNAMICS; VOLUME;
D O I
10.1080/02713683.2019.1629598
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The first aim of this study was to compare inferior tear meniscus height (TMH) measured by keratography and swept-source optical coherence tomography (OCT). Effect of locations of fluorescein instillation and subjects' subjective sensation, and the TMH results were also investigated. Methods: Forty-one eyes from 41 healthy adults had TMH randomly measured by keratography (K5M, Oculus, Germany) and swept-source OCT (Casia SS-1000, Tomey Corp, Japan) at baseline, followed by touching either the inferior bulbar or inferior palpebral conjunctiva, randomly assigned, with a moistened fluorescein strip. Two-way analysis of variance (ANOVA) was used to compare TMH obtained from the two devices and three measurement conditions. Subjective sensation of conjunctival touch was obtained through a 4-point scale with zero representing no sensation, and one to three representing ocular sensation in an ascending order. Results: Two-way ANOVA revealed no significant difference in TMH between keratography and swept-source OCT (Factor (devices): F = 0.579, p = .451) while there was a significant difference among fluorescein instillations (Factor (conditions): F = 10.146, p < .001). Baseline TMH was around 0.25 mm, and increased to around 0.28 mm after instillation of fluorescein sodium. Ocular sensation was similar between the two conjunctival touch, and TMH was not significantly associated with ocular sensation. Conclusions: Keratography and swept-source OCT provided similar TMH results. Applying fluorescein sodium through moistened fluorescein strip could over-estimate TMH by around 0.03 mm. Applying moistened fluorescein strip at bulbar or palpebral conjunctival led to similar subjective sensations and did not affect TMH measurement.
引用
收藏
页码:1203 / 1208
页数:6
相关论文
共 50 条
  • [21] Effect of image quality fluctuations on the repeatability of thickness measurements in swept-source optical coherence tomography
    Heon Yang
    Hye Sun Lee
    Hyoung Won Bae
    Gong Je Seong
    Chan Yun Kim
    Sang Yeop Lee
    Scientific Reports, 10
  • [22] Repeatability of Keratometry Measurements with Swept-Source Optical Coherence Tomography in Normal Eyes
    Poulsen, Anne
    Cui, Amy Lu David
    Seeger, Catherine
    Lehman, Erik
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [23] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [24] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [25] Cataract quantification using swept-source optical coherence tomography Reply
    Findl, Oliver
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 894 - 894
  • [26] Evaluation of Vitreous Cells Using Swept-Source Optical Coherence Tomography
    Choi, Rene
    Li, Yan
    Siak, Jay Jyh-Kuen
    Lu, Chen
    Lee, ByungKun
    Yang, Jianlong
    Liu, Gangjun
    Suhler, Eric B.
    Lin, Phoebe
    Fujimoto, James G.
    Rosenbaum, James T.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [27] Variability of the analysis of the tear meniscus height by optical coherence tomography
    Bitton, Etty
    Keech, Adam
    Simpson, Trefford
    Jones, Lyndon
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (09) : 903 - 908
  • [28] Clinical Observation of Choroidal Osteoma Using Swept-Source Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Xuan, Yi
    Chang, Qing
    Zhang, Yongjin
    Ye, Xiaofeng
    Liu, Wei
    Li, Lei
    Wang, Keyan
    Zhou, Jian
    Wang, Min
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [29] Swept-source optical coherence tomography of lower limb wound healing with histopathological correlation
    Barui, Ananya
    Banerjee, Provas
    Patra, Rusha
    Das, Raunak Kumar
    Dhara, Santanu
    Dutta, Pranab K.
    Chatterjee, Jyotirmoy
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (02)
  • [30] Swept-source optical coherence tomography and swept-source optical coherence tomography angiography findings in circumscribed choroidal hemangioma before and after transpupillary thermotherapy
    Mirzayev, Ibadulla
    Gunduz, Ahmet Kaan
    Ergin, Ahmet
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)