Lower Tear Meniscus Height Measurements Using Keratography and Swept-Source Optical Coherence Tomography and Effect of Fluorescein Instillation Methods

被引:10
|
作者
Lam, Andrew K. C. [1 ]
Tai, Shirley K. Y. [1 ]
Chan, Jacky K. T. [1 ]
Ng, Raymond W. E. [1 ]
机构
[1] Hong Kong Polytech Univ, Sch Optometry, Lab Expt Optometry, Hong Kong, Peoples R China
关键词
Tear meniscus height; keratography; swept-source optical coherence tomography; bulbar conjunctiva; palpebral conjunctiva; DRY EYE; PREVALENCE; DYNAMICS; VOLUME;
D O I
10.1080/02713683.2019.1629598
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The first aim of this study was to compare inferior tear meniscus height (TMH) measured by keratography and swept-source optical coherence tomography (OCT). Effect of locations of fluorescein instillation and subjects' subjective sensation, and the TMH results were also investigated. Methods: Forty-one eyes from 41 healthy adults had TMH randomly measured by keratography (K5M, Oculus, Germany) and swept-source OCT (Casia SS-1000, Tomey Corp, Japan) at baseline, followed by touching either the inferior bulbar or inferior palpebral conjunctiva, randomly assigned, with a moistened fluorescein strip. Two-way analysis of variance (ANOVA) was used to compare TMH obtained from the two devices and three measurement conditions. Subjective sensation of conjunctival touch was obtained through a 4-point scale with zero representing no sensation, and one to three representing ocular sensation in an ascending order. Results: Two-way ANOVA revealed no significant difference in TMH between keratography and swept-source OCT (Factor (devices): F = 0.579, p = .451) while there was a significant difference among fluorescein instillations (Factor (conditions): F = 10.146, p < .001). Baseline TMH was around 0.25 mm, and increased to around 0.28 mm after instillation of fluorescein sodium. Ocular sensation was similar between the two conjunctival touch, and TMH was not significantly associated with ocular sensation. Conclusions: Keratography and swept-source OCT provided similar TMH results. Applying fluorescein sodium through moistened fluorescein strip could over-estimate TMH by around 0.03 mm. Applying moistened fluorescein strip at bulbar or palpebral conjunctival led to similar subjective sensations and did not affect TMH measurement.
引用
收藏
页码:1203 / 1208
页数:6
相关论文
共 50 条
  • [31] Pilot Study of Lamina Cribrosa Intensity Measurements in Glaucoma Using Swept-Source Optical Coherence Tomography
    Srinivas, Sowmya
    Dastiridou, Anna
    Durbin, Mary K.
    Nittala, Muneeswar G.
    Huang, Alex A.
    Tan, James C. H.
    Francis, Brian A.
    Sadda, Srinivas R.
    Chopra, Vikas
    JOURNAL OF GLAUCOMA, 2017, 26 (02) : 138 - 143
  • [32] Effect of hydration on assessment of early enamel lesion using swept-source optical coherence tomography
    Nazari, Amir
    Sadr, Alireza
    Campillo-Funollet, Marc
    Nakashima, Syozi
    Shimada, Yasushi
    Tagami, Junji
    Sumi, Yasunori
    JOURNAL OF BIOPHOTONICS, 2013, 6 (02) : 171 - 177
  • [33] Evaluation of Choroidal Nevi with Swept-Source Optical Coherence Tomography
    Ung, Cindy
    Lains, Ines
    Woods, Russell L.
    Lane, Anne Marie
    Husain, Deeba
    Miller, Joan W.
    Gragoudas, Evangelos S.
    Kim, Ivana K.
    Miller, John B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [34] Swept-source optical coherence tomography angiography in serpiginous choroiditis
    Montorio, Daniela
    Giuffre, Chiara
    Miserocchi, Elisabetta
    Modorati, Giulio
    Sacconi, Riccardo
    Mercuri, Stefano
    Querques, Lea
    Querques, Giuseppe
    Bandello, Francesco
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (07) : 991 - 995
  • [35] Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
    Dong, Jing
    Yao, Jinhan
    Chang, Shuimiao
    Kanclerz, Piotr
    Khoramnia, Ramin
    Wang, Xiaogang
    MEDICINA-LITHUANIA, 2023, 59 (05):
  • [36] Defect inspection of actuator lenses using swept-source optical coherence tomography
    Jaeyul Lee
    Muhammad Faizan Shirazi
    Kibeom Park
    Mansik Jeon
    Jeehyun Kim
    Optical Review, 2018, 25 : 403 - 409
  • [37] Application of Keratograph and Fourier-Domain Optical Coherence Tomography in Measurements of Tear Meniscus Height
    Chen, Minjie
    Wei, Anji
    Xu, Jianjiang
    Zhou, Xingtao
    Hong, Jiaxu
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [38] Paper Insulation Aging Estimation Using Swept-Source Optical Coherence Tomography
    Mezgebo, Biniyam
    Sherif, Sherif S.
    Fernando, Namal
    Kordi, Behzad
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (01) : 30 - 37
  • [39] Swept-source visible-light optical coherence tomography
    Fan, Weijia
    Kuranov, Roman
    Miller, David a.
    Zhang, Tingwei
    Yeo, Wei-hong
    Atkinson, Raymond
    Zhang, Pengpeng
    Sun, Cheng
    Zhang, Hao f.
    OPTICS LETTERS, 2025, 50 (03) : 928 - 931
  • [40] Image artefacts in swept-source optical coherence tomography angiography
    Falavarjani, Khalil Ghasemi
    Al-Sheikh, Mayss
    Akil, Handan
    Sadda, Srinivas R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (05) : 564 - 568