Lower Tear Meniscus Height Measurements Using Keratography and Swept-Source Optical Coherence Tomography and Effect of Fluorescein Instillation Methods

被引:10
|
作者
Lam, Andrew K. C. [1 ]
Tai, Shirley K. Y. [1 ]
Chan, Jacky K. T. [1 ]
Ng, Raymond W. E. [1 ]
机构
[1] Hong Kong Polytech Univ, Sch Optometry, Lab Expt Optometry, Hong Kong, Peoples R China
关键词
Tear meniscus height; keratography; swept-source optical coherence tomography; bulbar conjunctiva; palpebral conjunctiva; DRY EYE; PREVALENCE; DYNAMICS; VOLUME;
D O I
10.1080/02713683.2019.1629598
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The first aim of this study was to compare inferior tear meniscus height (TMH) measured by keratography and swept-source optical coherence tomography (OCT). Effect of locations of fluorescein instillation and subjects' subjective sensation, and the TMH results were also investigated. Methods: Forty-one eyes from 41 healthy adults had TMH randomly measured by keratography (K5M, Oculus, Germany) and swept-source OCT (Casia SS-1000, Tomey Corp, Japan) at baseline, followed by touching either the inferior bulbar or inferior palpebral conjunctiva, randomly assigned, with a moistened fluorescein strip. Two-way analysis of variance (ANOVA) was used to compare TMH obtained from the two devices and three measurement conditions. Subjective sensation of conjunctival touch was obtained through a 4-point scale with zero representing no sensation, and one to three representing ocular sensation in an ascending order. Results: Two-way ANOVA revealed no significant difference in TMH between keratography and swept-source OCT (Factor (devices): F = 0.579, p = .451) while there was a significant difference among fluorescein instillations (Factor (conditions): F = 10.146, p < .001). Baseline TMH was around 0.25 mm, and increased to around 0.28 mm after instillation of fluorescein sodium. Ocular sensation was similar between the two conjunctival touch, and TMH was not significantly associated with ocular sensation. Conclusions: Keratography and swept-source OCT provided similar TMH results. Applying fluorescein sodium through moistened fluorescein strip could over-estimate TMH by around 0.03 mm. Applying moistened fluorescein strip at bulbar or palpebral conjunctival led to similar subjective sensations and did not affect TMH measurement.
引用
收藏
页码:1203 / 1208
页数:6
相关论文
共 50 条
  • [1] Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography
    Arriola-Villalobos, Pedro
    Ignacio Fernandez-Vigo, Jose
    Diaz-Valle, David
    Almendral-Gomez, Jaime
    Fernandez-Perez, Cristina
    Benitez-del-Castillo, Jose M.
    CORNEA, 2017, 36 (02) : 183 - 188
  • [2] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [3] Evaluation of Tear Meniscus Dynamics Using Anterior Segment Swept-Source Optical Coherence Tomography After Topical Solution Instillation for Dry Eye
    Akiyama-Fukuda, Reina
    Usui, Tomohiko
    Yoshida, Tatsuya
    Yamagami, Satoru
    CORNEA, 2016, 35 (05) : 654 - 658
  • [4] Iridociliary measurements using the Anterion swept-source optical coherence tomography
    Patyal, Sagarika
    Yadav, Arun
    Anthony, Hansel
    Ansari, Faisal
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (01) : 109 - 112
  • [5] Diagnosis of Dry Eye by Tear Meniscus Measurements Using Anterior Segment Swept Source Optical Coherence Tomography
    Akiyama, Reina
    Usui, Tomohiko
    Yamagami, Satoru
    CORNEA, 2015, 34 : S115 - S120
  • [6] Lower tear meniscus height measured by optical coherence tomography in children
    Martin-Garcia, Beatriz
    Palomo-Alvarez, Catalina
    Piedrahita-Alonso, Elena
    Gomez-de-Liano, Rosario
    Ferrer, Manuel Enrique Fuentes
    Arriola-Villalobos, Pedro
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1059 - 1064
  • [7] Tear meniscus dynamics after eye drop instillation evaluated by anterior segment swept source optical coherence tomography
    Fukuda, Reina
    Usui, Tomohiko
    Yamagami, Satoru
    Amano, Shiro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [8] Effects of 0.01% Atropine Instillation Assessed Using Swept-Source Anterior Segment Optical Coherence Tomography
    Mitsukawa, Tadahiro
    Suzuki, Yumi
    Momota, Yosuke
    Suzuki, Shun
    Yamada, Masakazu
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [9] Cataract quantification using swept-source optical coherence tomography
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1478 - 1481
  • [10] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894