Comparison of electrochemical property between multiwalled carbon nanotubes and porous graphitized carbon monolith modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid

被引:16
|
作者
Mukdasai, Siriboon [1 ]
Moore, Eric [2 ]
Glennon, Jeremy D. [3 ,4 ]
He, Xiaoyun [5 ]
Nesterenko, Ekaterina P. [5 ]
Nesterenko, Pavel N. [6 ]
Paull, Brett [6 ]
Pravda, Mila [3 ,4 ]
Srijaranai, Supalax [1 ]
机构
[1] Khon Kaen Univ, Fac Sci, Dept Chem, Mat Chem Res Ctr, Khon Kaen 40002, Thailand
[2] Tyndall Natl Inst, Cork, Ireland
[3] Natl Univ Ireland Univ Coll Cork, Dept Chem, Innovat Chromatog Grp, ISSC, Cork, Ireland
[4] Natl Univ Ireland Univ Coll Cork, ABCRF, Cork, Ireland
[5] Dublin City Univ, ISSC, Dublin 9, Ireland
[6] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
基金
爱尔兰科学基金会;
关键词
Porous graphitized carbon monolith; Multi-walled carbon nanotubes; Ascorbic acid; Uric acid; Modified glassy carbon electrode; SPECTROPHOTOMETRIC DETERMINATION; DOPAMINE; SENSOR; HPLC;
D O I
10.1016/j.jelechem.2014.07.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, glassy carbon electrode (GCE) was modified with porous graphitized carbon monolith (CM) as a new nanomaterials and multi-walled carbon nanotubes (MWCNTs) for simultaneous determination of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed for the surface analysis of the modified electrodes. In this simultaneous detection, the electrochemical response of AA and UA on MWCNTs/GCE exhibited broad anodic peaks and were resolved into separated CV peaks at +45 mV and +254 mV, respectively. In comparison, two well resolved peaks of CM/GCE were obtained at -39 mV and +233 mV with flat base-lines for oxidation of AA and UA, respectively. Under the optimum conditions, the performance of porous graphitized carbon monolith were superior to MWCNTs modified glassy carbon electrode. For CM/GCE, the oxidation peak current was linearly dependent on AA and UA concentration in the range 0.195-4.04 mM and 0.094-1.90 mM, with the correlation coefficients (R-2) greater than 0.997. Detection limits (S/N= 3) were found 0.39 u,M and 0.15 mu M for AA and UA, respectively. The recoveries of the AA and UA from spiked human serum were 76.0-94.2%. In addition, the CM/GCE showed high sensitivity, good reproducibility and long-time stability at least 1 month without significant loss of electrochemical signal. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [31] Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups
    Bi, Huaqing
    Li, Yanhui
    Liu, Shufeng
    Guo, Peizhi
    Wei, Zhongbin
    Lv, Chunxiao
    Zhang, Jizhen
    Zhao, X. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1132 - 1140
  • [32] Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    Zare, Hamid R.
    Nasirizadeh, Navid
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02): : 666 - 672
  • [33] Easy modification of glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Thiagarajan, Soundappan
    Tsai, Tsung-Hsuan
    Chen, Shen-Ming
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2712 - 2715
  • [34] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [35] Electrochemical characterization of poly(fuchsine acid) modified glassy carbon electrode and its application for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Taei, M.
    Hasanpour, F.
    Tavakkoli, N.
    Bahrameian, M.
    JOURNAL OF MOLECULAR LIQUIDS, 2015, 211 : 353 - 362
  • [36] Simultaneous determination of epinephrine and uric acid at ordered mesoporous carbon modified glassy carbon electrode
    Luo, Liqiang
    Li, Fang
    Zhu, Limei
    Ding, Yaping
    Zhang, Zhao
    Deng, Dongmei
    Lu, Bo
    ANALYTICAL METHODS, 2012, 4 (08) : 2417 - 2422
  • [37] Covalent modification of glassy carbon electrode with glutamic acid for simultaneous determination of uric acid and ascorbic acid
    Zhang, L
    Lin, XQ
    ANALYST, 2001, 126 (03) : 367 - 370
  • [38] Selective Simultaneous Determination of Paracetamol and Uric Acid Using a Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite
    Babaei, Ali
    Garrett, David J.
    Downard, Alison J.
    ELECTROANALYSIS, 2011, 23 (02) : 417 - 423
  • [39] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [40] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    D. M. Sun
    W. N. Hu
    W. Ma
    Journal of Analytical Chemistry, 2011, 66 : 310 - 316