Comparison of electrochemical property between multiwalled carbon nanotubes and porous graphitized carbon monolith modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid

被引:16
|
作者
Mukdasai, Siriboon [1 ]
Moore, Eric [2 ]
Glennon, Jeremy D. [3 ,4 ]
He, Xiaoyun [5 ]
Nesterenko, Ekaterina P. [5 ]
Nesterenko, Pavel N. [6 ]
Paull, Brett [6 ]
Pravda, Mila [3 ,4 ]
Srijaranai, Supalax [1 ]
机构
[1] Khon Kaen Univ, Fac Sci, Dept Chem, Mat Chem Res Ctr, Khon Kaen 40002, Thailand
[2] Tyndall Natl Inst, Cork, Ireland
[3] Natl Univ Ireland Univ Coll Cork, Dept Chem, Innovat Chromatog Grp, ISSC, Cork, Ireland
[4] Natl Univ Ireland Univ Coll Cork, ABCRF, Cork, Ireland
[5] Dublin City Univ, ISSC, Dublin 9, Ireland
[6] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
基金
爱尔兰科学基金会;
关键词
Porous graphitized carbon monolith; Multi-walled carbon nanotubes; Ascorbic acid; Uric acid; Modified glassy carbon electrode; SPECTROPHOTOMETRIC DETERMINATION; DOPAMINE; SENSOR; HPLC;
D O I
10.1016/j.jelechem.2014.07.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, glassy carbon electrode (GCE) was modified with porous graphitized carbon monolith (CM) as a new nanomaterials and multi-walled carbon nanotubes (MWCNTs) for simultaneous determination of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed for the surface analysis of the modified electrodes. In this simultaneous detection, the electrochemical response of AA and UA on MWCNTs/GCE exhibited broad anodic peaks and were resolved into separated CV peaks at +45 mV and +254 mV, respectively. In comparison, two well resolved peaks of CM/GCE were obtained at -39 mV and +233 mV with flat base-lines for oxidation of AA and UA, respectively. Under the optimum conditions, the performance of porous graphitized carbon monolith were superior to MWCNTs modified glassy carbon electrode. For CM/GCE, the oxidation peak current was linearly dependent on AA and UA concentration in the range 0.195-4.04 mM and 0.094-1.90 mM, with the correlation coefficients (R-2) greater than 0.997. Detection limits (S/N= 3) were found 0.39 u,M and 0.15 mu M for AA and UA, respectively. The recoveries of the AA and UA from spiked human serum were 76.0-94.2%. In addition, the CM/GCE showed high sensitivity, good reproducibility and long-time stability at least 1 month without significant loss of electrochemical signal. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [41] Poly(pyridine-3-boronic acid)/Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrodes for Simultaneous Determination of Ascorbic Acid, 3,4-Dihydroxyphenylacetic Acid and Uric Acid
    Wu, Zhijiao
    Zhao, Hong
    Xue, Ying
    He, Yujian
    Li, Xiangjun
    Yuan, Zhuobin
    ELECTROANALYSIS, 2010, 22 (19) : 2196 - 2201
  • [42] Room Temperature Ionic Liquid/Multiwalled Carbon Nanotube/Chitosan-Modified Glassy Carbon Electrode as a Sensor for Simultaneous Determination of Ascorbic Acid, Uric Acid, Acetaminophen, and Mefenamic Acid
    Kianipour, Shokat
    Asghari, Alireza
    IEEE SENSORS JOURNAL, 2013, 13 (07) : 2690 - 2698
  • [43] Voltammetric determination of uric acid with a glassy carbon electrode coated by paste of multiwalled carbon nanotubes and ionic liquid
    Yan, Quanping
    Zhao, Faqiong
    Li, Guangzu
    Zeng, Baizhao
    ELECTROANALYSIS, 2006, 18 (11) : 1075 - 1080
  • [44] Modification of glassy carbon electrode in basic medium by electrochemical treatment for simultaneous determination of dopamine, ascorbic acid and uric acid
    Temocin, Zulfikar
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 796 - 802
  • [45] Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    Cao, Xiaomei
    Xu, Yanhong
    Luo, Liqiang
    Ding, Yaping
    Zhang, Ying
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (05) : 829 - 834
  • [46] Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2008, 53 (22) : 6610 - 6615
  • [47] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [48] A new sensor based on glassy carbon electrode modified with nanocomposite for simultaneous determination of acetaminophen, ascorbic acid and uric acid
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Babaei, Ali
    Nasimi, Ali Asghar
    Shabanian, Meisam
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S480 - S487
  • [49] Phloroglucinol/activated carbon composite/multiwalled carbon nanotubes modified glassy carbon electrode for electrochemical quantification of caffeic acid
    Tigari, Girish
    Yhobu, Zhoveta
    Budagumpi, Srinivasa
    Keri, Rangappa S.
    INORGANIC CHEMISTRY COMMUNICATIONS, 2023, 158
  • [50] Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    Xiaomei Cao
    Yanhong Xu
    Liqiang Luo
    Yaping Ding
    Ying Zhang
    Journal of Solid State Electrochemistry, 2010, 14 : 829 - 834