Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1099期
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France
    Baysson, Helene
    Rehel, Jean Luc
    Boudjemline, Younes
    Petit, Jerome
    Girodon, Brigitte
    Aubert, Bernard
    Laurier, Dominique
    Bonnet, Damien
    Bernier, Marie-Odile
    BMC PUBLIC HEALTH, 2013, 13
  • [42] Anesthesia for cardiac catheterization procedures
    Hamid, M.
    HEART LUNG AND VESSELS, 2014, 6 (04) : 225 - 231
  • [43] Evaluation of radiation dose to pediatric patients during certain special procedures
    Sulieman, A.
    Alzimami, K.
    Elhag, B.
    Babikir, E.
    Alsafi, K.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 267 - 271
  • [44] Radiation dose among different cardiac and vascular invasive procedures: The RODEO study
    Sciahbasi, Alessandro
    Ferrante, Giuseppe
    Fischetti, Dionigi
    Miklin, Daniel Jonathan
    Sarandrea, Alessandro
    Schirripa, Valentina
    Guarracini, Fabrizio
    Arya, Arash
    Loreni, Giorgio
    Bruni, Antonio
    Rigattieri, Stefano
    Marini, Massimiliano
    Vagnarelli, Simone
    Scevola, Germano
    Reimers, Bernhard
    Hindricks, Gerhard
    Cohen, Mauricio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 240 : 92 - 96
  • [45] Effective Radiation Dose in Computed Tomographic Angiography of the Chest and Diagnostic Cardiac Catheterization in Pediatric Patients
    Watson, Timotheus G.
    Mah, Eugene
    Schoepf, U. Joseph
    King, Lydia
    Huda, Walter
    Hlavacek, Anthony M.
    PEDIATRIC CARDIOLOGY, 2013, 34 (03) : 518 - 524
  • [46] Effective Reduction of Radiation Exposure during Cardiac Catheterization
    Gutierrez-Barrios, Alejandro
    Camacho-Galan, Hugo
    Medina-Camacho, Francisco
    Canadas-Pruano, Dolores
    Jimenez-Moreno, Antonio
    Calle-Perez, German
    Vazquez-Garcia, Rafael
    TEXAS HEART INSTITUTE JOURNAL, 2019, 46 (03): : 167 - 171
  • [47] A COMPARATIVE STUDY OF ACTIVATED CLOTTING TIME (ACT) ACHIEVED BY WEIGHT ADJUSTED AND FIXED DOSE OF UNFRACTIONATED HEPARIN DURING CARDIAC CATHETERIZATION PROCEDURES
    Adnan, Asif
    Jadhav, Sachin
    Gondal, Mohsin
    Harcombe, Alun
    HEART, 2018, 104 : A57 - A58
  • [48] Effect of a Real-Time Radiation Monitoring Device on Operator Radiation Exposure During Cardiac Catheterization The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring Study
    Christopoulos, Georgios
    Papayannis, Aristotelis C.
    Alomar, Mohammed
    Kotsia, Anna
    Michael, Tesfaldet T.
    Rangan, Bavana V.
    Roesle, Michele
    Shorrock, Deborah
    Makke, Lorenza
    Layne, Ronald
    Grabarkewitz, Rebecca
    Haagen, Donald
    Maragkoudakis, Spyros
    Mohammad, Atif
    Sarode, Karan
    Cipher, Daisha J.
    Chambers, Charles E.
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 744 - 750
  • [49] Effective Radiation Dose in Computed Tomographic Angiography of the Chest and Diagnostic Cardiac Catheterization in Pediatric Patients
    Timotheus G. Watson
    Eugene Mah
    U. Joseph Schoepf
    Lydia King
    Walter Huda
    Anthony M. Hlavacek
    Pediatric Cardiology, 2013, 34 : 518 - 524
  • [50] RADIATION REDUCTION DURING PEDIATRIC CARDIAC-CATHETERIZATION
    CULHAM, JAG
    LUNEY, B
    WESTRALUNEY, M
    BURGESS, A
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : B69 - B69