Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1099期
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] RADIATION EXPOSURE DURING CARDIAC-CATHETERIZATION
    FALICOV, RE
    CIRCULATION, 1978, 58 (06) : 1213 - 1213
  • [32] RADIATION EXPOSURE TO PERSONNEL DURING CARDIAC CATHETERIZATION
    ARDRAN, GM
    FURSDON, PS
    RADIOLOGY, 1973, 106 (03) : 517 - 518
  • [33] Cardiac catheterization procedures in pediatric patients undergoing extracorporeal membrane oxygenation cardiac catheterization, ECMO
    Guzeltas, Alper
    Kasar, Taner
    Tanidir, Ibrahim Cansaran
    Ozturk, Erkut
    Yildiz, Okan
    Haydin, Sertac
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 18 (06): : 425 - 430
  • [34] Lowering fluoroscopy pulse rates to reduce radiation dose during cardiac procedures
    Crowhurst, James
    Whitby, Mark
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2018, 65 (04): : 247 - 249
  • [35] A mathematical model for patient skin dose assessment in cardiac catheterization procedures
    Morrell, R. E.
    Rogers, A. T.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945): : 756 - 761
  • [36] Strategy to reduce radiation dose in cardiac catheterization laboratory-a phantom based study
    Sharma, Divyesh
    Shah, Ashish
    Ursani, Ali
    Barolet, Alan
    Seidelin, Peter H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B112 - B113
  • [37] COMPARISON OF RADIATION-DOSE RECEIVED DURING EITHER ELECTROPHYSIOLOGY STUDY AND RADIOFREQUENCY ABLATION OR CARDIAC-CATHETERIZATION IN CHILDREN
    KOWALSKI, CA
    DOROSTKAR, PC
    MIKLOS, JA
    LLOYD, T
    BEEKMAN, R
    ARMSTRONG, B
    DICK, M
    CIRCULATION, 1994, 90 (04) : 99 - 99
  • [38] Analysis and consideration of radiation dose distribution in cardiac catheterization interventions
    You, Z.
    Liu, Y.
    Li, C.
    Hu, A.
    Liu, X.
    Li, W.
    Liao, L.
    Liu, F.
    RADIOPROTECTION, 2025, 60 (01) : 20 - 27
  • [39] Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France
    Helene Baysson
    Jean Luc Réhel
    Younes Boudjemline
    Jerôme Petit
    Brigitte Girodon
    Bernard Aubert
    Dominique Laurier
    Damien Bonnet
    Marie-Odile Bernier
    BMC Public Health, 13
  • [40] Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a New Absorption Shielding Drape
    Nadelson, Jeffrey
    Ertel, Andrew
    Ferrera, Dean
    Sweis, Ranya N.
    Shroff, Adhir R.
    Vidovich, Mladen I.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B163 - B163