Retrospective study of patients radiation dose during cardiac catheterization procedures

被引:11
|
作者
Osei, Beverley [1 ,2 ]
Xu, Lu [2 ,3 ]
Johnston, Amanda [4 ]
Darko, Sara [5 ]
Darko, Johnson [2 ,6 ,7 ]
Osei, Ernest [2 ,6 ,7 ,8 ]
机构
[1] McMaster Univ, Dept Hlth Sci, Hamilton, ON, Canada
[2] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON, Canada
[3] Western Univ, Dept Med Sci IMS & Med Biophys, London, ON, Canada
[4] St Mary Gen Hosp, Kitchener, ON, Canada
[5] Grand River Reg Canc Ctr, Dept Clin Trials, Kitchener, ON, Canada
[6] Univ Waterloo, Dept Phys & Astron, Waterloo, ON, Canada
[7] Univ Guelph, Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[8] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1099期
关键词
FLUOROSCOPICALLY GUIDED PROCEDURES; CORONARY-ANGIOGRAPHY; INTERVENTIONAL CARDIOLOGY; SKIN INJURIES; EXPOSURE; SAFETY; RISK; IMPLANTATION; ARTERIES; VALUES;
D O I
10.1259/bjr.20181021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Cardiac catheterization procedures provide tremendous benefits to modern healthcare and the benefit derived by the patient should far outweigh the radiation risk associated with a properly optimized procedure. With increasing utilization of such procedures, there is growing concern regarding the magnitude and variations of dose to patients associated with procedure complexity and techniques parameters. Therefore, this study investigated radiation dose to patients from six cardiac catheterization procedures at our facility and suggest possible initial dose values for benchmark for patient radiation dose from these procedures. This initial benchmark data will be used for clinical radiation dose management which is essential for assessing the impact of any quality improvement initiatives in the cardiac catheterization laboratory. Methods: We retrospectively analyzed the dose parameters of 1000 patients who underwent various cardiac catheterization procedures: left heart catheterization (LH), percutaneous coronary intervention (PCI), complex PCI, LH with complex PCI, LH with PCI and cardiac resynchronization therapy (CRT) pacemaker in our cardiac catheterization laboratories. Patient's clinical radiation dose data [kerma-area-product (KAP) and air-kerma at the interventional reference point (K-a,K-r)] and technique parameters (fluoroscopy time, tube potential, current, pulse width and number tine images) along with demographic information (age, height and weight) were collected from the hospital's RIS (Synapse), Sensis/Syngo Dynamics and Siemens Sensis Stats Manager electronic database. Statistical analysis was performed with the IBM SPSS Modeler v. 18.1 software. Results: The overall patient median age was 67.0 (range: 26.0-97.0) years and the median body mass index (BMI) was 28.8 (range: 15.9-61.7) kg/m(2) The median KAP for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 44.4 (4.1-203.2), 80.2 (18.9-208.5), 83.7 (48.0-246.1), 113.8 (60.9-284.5), 91.7 (6.0-426.0) and 51.1 (7.0-175.9) Gy-cm(2) The median K-a,K-r for the LH, PCI, LH with complex PCI, complex PCI, LH with PCI and CRT-pacemaker procedures are 701.0 (35.3-3794.0), 1384.7 (291.7-4021.8), 1607.0 (883.5-4448.3), 2260.2 (867.4-5311.9), 1589.3 (100.2-7237.4) and 463.8 (67.7-1695.9) mGy respectively. Conclusion: We have analyzed patient radiation doses from six commonly used procedures in our cardiac catheterization laboratories and suggested possible initial values for benchmark from these procedures for the fluoroscopy time, KAP and air-kerma at the interventional reference point based on our current practices. Our data compare well with published values reported in the literature by investigators who have also studied patient doses and established benchmark dose levels for their facilities. Procedure-specific benchmark dose data for various groups of patients can provide the motivation for monitoring practices to promote improvements in patient radiation dose optimization in the cardiac catheterization laboratories. Advances in knowledge: We have investigated local patients' radiation doses and established benchmark radiation data which are essential for assessing the impact of any quality improvement initiatives for radiation dose optimization.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Patient effective doses and radiation risks in cardiac catheterization procedures
    Sulieman, A.
    Abdelrazig, A.
    Alkhorayef, M.
    Babikir, E.
    Al-Mohammed, H. I.
    Al-Mugren, K. S.
    Bradley, D.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 157 : 54 - 59
  • [22] The Impact of Patient BMI on Radiation Dose Among Scrub Technologists During Cardiac Catheterization
    Refahiyat, Lahdan
    Clarey, Austin
    Bundy, Jacob
    Mandieka, Edwin
    Benavides, David
    Crane, Thomas
    Maragiri, Sheetal
    Osip, Erica
    Pardington, Emily
    Samani, Soroush
    Mulder, Abbey
    Ten Brock, Taylor
    Parker, Jessica
    Vanoosterhout, Stacie
    Madder, Ryan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S39 - S39
  • [23] RADIATION DOSE BENCHMARKS DURING CARDIAC CATHETERIZATION FOR CONGENITAL HEART DISEASE IN THE UNITED STATES
    Ghelani, Sunil J.
    Glatz, Andrew
    David, Sthuthi
    Leahy, Ryan
    Hirsch, Russel
    Armsby, Laurie
    Trucco, Sara
    Holzer, Ralf
    Bergersen, Lisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A495 - A495
  • [24] A Radiation Dose Reduction Technology to Improve Patient Safety During Cardiac Catheterization Interventions
    Bracken, John A.
    Mauti, Maria
    Kim, Michael S.
    Messenger, John C.
    Carroll, John D.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (05) : 493 - 497
  • [25] Radiation Dose Benchmarks During Cardiac Catheterization for Congenital Heart Disease in the United States
    Ghelani, Sunil J.
    Glatz, Andrew C.
    David, Sthuthi
    Leahy, Ryan
    Hirsch, Russel
    Armsby, Laurie B.
    Trucco, Sara M.
    Holzer, Ralf J.
    Bergersen, Lisa
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (09) : 1060 - 1069
  • [26] Radiation exposure during cardiac catheterization in children
    Schueler, BA
    Julsrud, PR
    Gray, JE
    Stears, JG
    Wu, KY
    ENVIRONMENTAL DOSE RECONSTRUCTION AND RISK IMPLICATIONS: NCRP - PROCEEDINGS OF THE THIRTY-FIRST ANNUAL MEETING, 12-13 APRIL, 1995, AS PRESENTED AT THE CRYSTAL CITY MARRIOTT, ARLINGTON, MA, ISSUED OCTOBER 1, 1996, 1996, (17): : 293 - 298
  • [27] Why measure radiation during cardiac catheterization?
    Balter, S
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 43 (04): : 371 - 371
  • [28] RADIATION EXPOSURE DURING CARDIAC-CATHETERIZATION
    LLOYD, DC
    COOPER, SJ
    WALL, BF
    LANCET, 1976, 1 (7964): : 854 - 855
  • [29] Radiation exposure to children during cardiac catheterization
    Boothroyd, A
    McDonald, E
    Moores, BM
    Sluming, V
    Carty, H
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 180 - 185
  • [30] RADIATION EXPOSURE DURING CARDIAC-CATHETERIZATION
    STOTT, ANB
    LANCET, 1976, 1 (7969): : 1131 - 1131