Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency

被引:10
|
作者
Rugge, Massimo [1 ,2 ,3 ]
Sacchi, Diana [1 ]
Genta, Robert M. [3 ]
Zanco, Francesca [1 ]
Guzzinati, Stefano [2 ]
Pizzi, Marco [1 ]
Fassan, Matteo [1 ]
Di Sabatino, Antonio [4 ]
El-Serag, Hashem [3 ]
机构
[1] Univ Padua, Dept Med DIMED, Surg Pathol & Cytopathol Unit, Via A Gabelli 61, I-35121 Padua, Italy
[2] Azienda Zero, Veneto Tumor Registry RTV, Padua, Italy
[3] Baylor Coll Med, Michael E DeBakey VA Med Ctr, Dept Med, Houston, TX 77030 USA
[4] Univ Pavia, IRCCS San Matteo Hosp Fdn, Dept Med 1, Pavia, Italy
关键词
Pseudopyloric metaplasia; PPM; SPEM; Atrophic gastritis; Autoimmune gastritis; INTESTINAL METAPLASIA; OBSERVER AGREEMENT; OPERATIVE LINK; ATROPHY; OLGA; CLASSIFICATION; INCISURA; MARKER; RISK;
D O I
10.1016/j.dld.2020.09.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). Aims: Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. Materials and methods: Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient. Results: Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good"(k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good"(k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent"(k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91). Conclusion: Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently. (C) 2020 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [41] Equilibrium radionuclide angiography: Intra- and inter-observer repeatability and reproducibility in the assessment of cardiac systolic and diastolic function
    Christos Sachpekidis
    Vasileios Sachpekidis
    Annette Kopp-Schneider
    George Arsos
    Efstratios Moralidis
    Journal of Nuclear Cardiology, 2021, 28 : 1304 - 1314
  • [42] Assessment of the axial rotation of the pelvis with the EOS® imaging system: Intra- and inter-observer reproducibility and accuracy study
    Rousseau M.-A.
    Brusson A.
    Lazennec J.-Y.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 891 - 895
  • [43] Equilibrium radionuclide angiography: Intra- and inter-observer repeatability and reproducibility in the assessment of cardiac systolic and diastolic function
    Sachpekidis, Christos
    Sachpekidis, Vasileios
    Kopp-Schneider, Annette
    Arsos, George
    Moralidis, Efstratios
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1304 - 1314
  • [44] Psoriasis severity assessment with a computational similarity-clustering programme reduces intra- and inter-observer variation
    Garakani, A.
    Manole, I.
    Walmink, W.
    Rossler, A. Young-San
    Zibert, J.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2018, 138 (05) : S96 - S96
  • [45] The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability
    Dwyer, Tim
    Whelan, Daniel B.
    Khoshbin, Amir
    Wasserstein, David
    Dold, Andrew
    Chahal, Jaskarndip
    Nauth, Aaron
    Murnaghan, M. Lucas
    Ogilvie-Harris, Darrell J.
    Theodoropoulos, John S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (04) : 1197 - 1200
  • [46] Intra- and Inter-Observer Agreement on CT Scan Features of Chronic Pancreatitis (CP)
    Dasyam, A. K.
    Tirkes, T.
    Shah, Z. K.
    Tang, G.
    Vipperla, K.
    Greer, P. J.
    Topazian, M.
    Fogel, E. L.
    Conwell, D. L.
    Yadav, D.
    Takahashi, N.
    PANCREAS, 2017, 46 (10) : 1396 - 1396
  • [47] Assessment of quadriceps muscle mass with ultrasound in critically ill patients: intra- and inter-observer agreement and sensitivity
    Segers, Johan
    Hermans, Greet
    Charususin, Noppawan
    Fivez, Tom
    Vanhorebeek, Ilse
    Van den Berghe, Greet
    Gosselink, Rik
    INTENSIVE CARE MEDICINE, 2015, 41 (03) : 562 - 563
  • [48] Robustness of Radiomics On Head and Neck CTs: Intra- and Inter-Observer Contouring Effects
    Crosby, J.
    Miller, T.
    Li, H.
    Lan, L.
    Ginat, D.
    Giger, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3018 - 3018
  • [49] The intra- and inter-observer reliability of the Samilson and Prieto grading system of glenohumeral arthropathy
    A. Ilg
    M. Bankes
    R. Emery
    Knee Surgery, Sports Traumatology, Arthroscopy, 2001, 9 : 187 - 190
  • [50] The intra- and inter-observer reliability of the Samilson and Prieto grading system of glenohumeral arthropathy
    Ilg, A
    Bankes, MJK
    Emery, RJH
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (03) : 187 - 190