Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency

被引:10
|
作者
Rugge, Massimo [1 ,2 ,3 ]
Sacchi, Diana [1 ]
Genta, Robert M. [3 ]
Zanco, Francesca [1 ]
Guzzinati, Stefano [2 ]
Pizzi, Marco [1 ]
Fassan, Matteo [1 ]
Di Sabatino, Antonio [4 ]
El-Serag, Hashem [3 ]
机构
[1] Univ Padua, Dept Med DIMED, Surg Pathol & Cytopathol Unit, Via A Gabelli 61, I-35121 Padua, Italy
[2] Azienda Zero, Veneto Tumor Registry RTV, Padua, Italy
[3] Baylor Coll Med, Michael E DeBakey VA Med Ctr, Dept Med, Houston, TX 77030 USA
[4] Univ Pavia, IRCCS San Matteo Hosp Fdn, Dept Med 1, Pavia, Italy
关键词
Pseudopyloric metaplasia; PPM; SPEM; Atrophic gastritis; Autoimmune gastritis; INTESTINAL METAPLASIA; OBSERVER AGREEMENT; OPERATIVE LINK; ATROPHY; OLGA; CLASSIFICATION; INCISURA; MARKER; RISK;
D O I
10.1016/j.dld.2020.09.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). Aims: Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. Materials and methods: Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient. Results: Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good"(k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good"(k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent"(k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91). Conclusion: Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently. (C) 2020 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [21] Ultrasonographical examination of feline adrenal glands: intra- and inter-observer variability
    Combes, Anais
    Stock, Emmelie
    Van der Vekens, Elke
    Duchateau, Luc
    Van Ryssen, Bernadette
    Saunders, Jimmy H.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2014, 16 (12) : 937 - 942
  • [22] Intra- and inter-observer reproducibility of QRS duration measurement in CRT patients
    Thebault, C.
    Kervio, G.
    Gervais, R.
    Donal, E.
    Mabo, P.
    Linde, C.
    Daubert, C.
    EUROPEAN HEART JOURNAL, 2010, 31 : 266 - 266
  • [23] Intra- and inter-observer reproducibility of masked Goldmann applanation tonometry measurements
    Trevino, Rick
    Majcher, Carolyn
    Sponsel, William Eric
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [24] Strategies for dealing with intra- and inter-observer variation in target volume definition
    Holmberg, O
    McClean, B
    McGibney, C
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S202 - S203
  • [25] Intra- and inter-observer agreement of a protocol for clinical examination of dairy cows
    Thomsen, PT
    Baadsgaard, NP
    PREVENTIVE VETERINARY MEDICINE, 2006, 75 (1-2) : 133 - 139
  • [26] Intra- and inter-observer reproducibility in the evaluation of the optic disc by HRT.
    Miglior, S
    Albe, E
    Guareschi, M
    Rossetti, L
    Orzalesi, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S16 - S16
  • [27] Intra- and inter-observer concordance of a fascial standing flexion test in children
    Conde-Vazquez, Orlando
    Mohino-Fernandez, Carlos
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2022, 30 : 95 - 99
  • [28] INTRA- AND INTER-OBSERVER AGREEMENT OF PROXIMAL HUMERAL FRACTURES CLASSIFICATIONS IN ADULTS
    Diaz, Luis Eduardo Plumacher
    Neto, Francisco Dada
    Lofrano, Lucas
    Garcia, Joao Vitor da Cruz
    Santana, Marcos Vinicius Felix
    Dobashi, Eiffel Tsuyoshi
    ACTA ORTOPEDICA BRASILEIRA, 2022, 30 (06):
  • [29] Intra- and Inter-observer Variability in Different Methods of Measuring Carpal Collapse
    Agrawal, S.
    Chabra, T.
    Pandey, S.
    Bhardwaj, P.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2019, 13 (01) : 20 - 24
  • [30] Analysis of the Intra- and Inter-observer Reliabilities of Delbet Classification: Is Simplification Required
    Muhammet Bozoğlan
    Gökhan Cansabuncu
    Mert Kumbaraci
    Safa Bozkurt
    Ali Turgut
    Indian Journal of Orthopaedics, 2023, 57 : 1478 - 1484