Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency

被引:10
|
作者
Rugge, Massimo [1 ,2 ,3 ]
Sacchi, Diana [1 ]
Genta, Robert M. [3 ]
Zanco, Francesca [1 ]
Guzzinati, Stefano [2 ]
Pizzi, Marco [1 ]
Fassan, Matteo [1 ]
Di Sabatino, Antonio [4 ]
El-Serag, Hashem [3 ]
机构
[1] Univ Padua, Dept Med DIMED, Surg Pathol & Cytopathol Unit, Via A Gabelli 61, I-35121 Padua, Italy
[2] Azienda Zero, Veneto Tumor Registry RTV, Padua, Italy
[3] Baylor Coll Med, Michael E DeBakey VA Med Ctr, Dept Med, Houston, TX 77030 USA
[4] Univ Pavia, IRCCS San Matteo Hosp Fdn, Dept Med 1, Pavia, Italy
关键词
Pseudopyloric metaplasia; PPM; SPEM; Atrophic gastritis; Autoimmune gastritis; INTESTINAL METAPLASIA; OBSERVER AGREEMENT; OPERATIVE LINK; ATROPHY; OLGA; CLASSIFICATION; INCISURA; MARKER; RISK;
D O I
10.1016/j.dld.2020.09.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). Aims: Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. Materials and methods: Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient. Results: Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good"(k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good"(k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent"(k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91). Conclusion: Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently. (C) 2020 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [31] Intra- and inter-observer variability in the classification of endoscopic patterns of gastric mucosa using chromoendoscopy and magnification endoscopy
    Dinis-Ribeiro, MJ
    Costa-Pereira, A
    Lopes, C
    Moreira-Dias, L
    Lomba-Viana, H
    Ribeiro, A
    Santos, C
    Soares, J
    Mesquita, N
    Silva, R
    Lomba-Viana, R
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB103 - AB103
  • [32] Analysis of the Intra- and Inter-observer Reliabilities of Delbet Classification: Is Simplification Required
    Bozoglan, Muhammet
    Cansabuncu, Gokhan
    Kumbaraci, Mert
    Bozkurt, Safa
    Turgut, Ali
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (09) : 1478 - 1484
  • [33] Intra- and inter-observer reliability of the novel vertebral bone quality score
    Mierke, Alex
    Ramos, Omar
    Macneille, Rhett
    Chung, Jun Ho
    Wycliffe, Nathaniel
    Cheng, Wayne
    Danisa, Olumide A.
    EUROPEAN SPINE JOURNAL, 2022, 31 (04) : 843 - 850
  • [34] Intra- and inter-observer reliability of the novel vertebral bone quality score
    Alex Mierke
    Omar Ramos
    Rhett Macneille
    Jun Ho Chung
    Nathaniel Wycliffe
    Wayne Cheng
    Olumide A. Danisa
    European Spine Journal, 2022, 31 : 843 - 850
  • [35] Diaphragm Thickness Measurement in Computed Tomography: Intra- and Inter-Observer Agreement
    Ufuk, Furkan
    Cakmak, Pinar
    Sagtas, Ergin
    Herek, Duygu
    Arslan, Muhammet
    Yagci, Ahmet Baki
    ISTANBUL MEDICAL JOURNAL, 2019, 20 (02): : 101 - 106
  • [36] Intra- and inter-observer reliability of ten major histological scoring systems used for the evaluation of in vivo cartilage repair
    Davide Edoardo Bonasia
    Antongiulio Marmotti
    Alessandro Domenico Felice Massa
    Andrea Ferro
    Davide Blonna
    Filippo Castoldi
    Roberto Rossi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2484 - 2493
  • [37] Intra- and inter-observer reliability of ten major histological scoring systems used for the evaluation of in vivo cartilage repair
    Bonasia, Davide Edoardo
    Marmotti, Antongiulio
    Massa, Alessandro Domenico Felice
    Ferro, Andrea
    Blonna, Davide
    Castoldi, Filippo
    Rossi, Roberto
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (09) : 2484 - 2493
  • [38] Intra- and inter-observer variation in histological criteria used in age at death determination based on femoral cortical bone
    Lynnerup, N
    Thomsen, JL
    Frohlich, B
    FORENSIC SCIENCE INTERNATIONAL, 1998, 91 (03) : 219 - 230
  • [39] Assessment of quadriceps muscle mass with ultrasound in critically ill patients: intra- and inter-observer agreement and sensitivity
    Johan Segers
    Greet Hermans
    Noppawan Charususin
    Tom Fivez
    Ilse Vanhorebeek
    Greet Van den Berghe
    Rik Gosselink
    Intensive Care Medicine, 2015, 41 : 562 - 563
  • [40] Assessment of Intra- and Inter-observer Measurement Variability in a Radiographic Metacarpophalangeal Joint Osteophytosis Scoring System for the Horse
    Lacitignola, Luca
    Imperante, Annarita
    Staffieri, Francesco
    De Siena, Rocco
    De Luca, Pasquale
    Muci, Arianna
    Crovace, Antonio
    VETERINARY SCIENCES, 2020, 7 (02)