Histological assessment of gastric pseudopyloric metaplasia: Intra- and inter-observer consistency

被引:10
|
作者
Rugge, Massimo [1 ,2 ,3 ]
Sacchi, Diana [1 ]
Genta, Robert M. [3 ]
Zanco, Francesca [1 ]
Guzzinati, Stefano [2 ]
Pizzi, Marco [1 ]
Fassan, Matteo [1 ]
Di Sabatino, Antonio [4 ]
El-Serag, Hashem [3 ]
机构
[1] Univ Padua, Dept Med DIMED, Surg Pathol & Cytopathol Unit, Via A Gabelli 61, I-35121 Padua, Italy
[2] Azienda Zero, Veneto Tumor Registry RTV, Padua, Italy
[3] Baylor Coll Med, Michael E DeBakey VA Med Ctr, Dept Med, Houston, TX 77030 USA
[4] Univ Pavia, IRCCS San Matteo Hosp Fdn, Dept Med 1, Pavia, Italy
关键词
Pseudopyloric metaplasia; PPM; SPEM; Atrophic gastritis; Autoimmune gastritis; INTESTINAL METAPLASIA; OBSERVER AGREEMENT; OPERATIVE LINK; ATROPHY; OLGA; CLASSIFICATION; INCISURA; MARKER; RISK;
D O I
10.1016/j.dld.2020.09.003
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The histological spectrum of oxyntic mucosal atrophy (a major determinant of gastric cancer risk) includes pseudopyloric metaplasia (PPM), which histological assessment has been regarded as unreliable. PPM consistently expresses Trefoil-Factor 2 (TFF2), which is histochemically detecteble (TFF2-IHC). Aims: Intra- and inter-observer consistency in assessing PPM was examined using both hematoxylin & eosin (H&E) and TFF2-IHC. Materials and methods: Seventy-four oxyntic biopsy samples obtained from autoimmune gastritis were considered. Two serial histological sections obtained from the paraffin-embedded tissue-samples were stained with H&E and TFF2-IHC. Three pathologists (Alpha, Beta, Gamma) independently scored PPM by both staining and the Intra- and inter-observer consistency (H&E versus TFF2-IHC) was calculated using k-statistics and/or Spearman's coefficient. Results: Based on H&E-stain versus TFF2-IHC, intra-observer consistency in PPM assessement was ranked as consistently "good"(k-values: Alpha=0.79; Beta=0.78; Gamma=0.75). Based on H&E, the overall PPM inter-observer consistency among the 3 observers was ranked as "good"(k=0.77) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=0.88; Alpha versus Gamma k=0.87; Beta versus Gamma k=0.80). Based on TFF2-IHC, the overall PPM inter-observer agreement was ranked as "excellent"(k=0.91) (the inter-observer consistency for pairs of observers was as follows: Alpha versus Beta k=1; Alpha versus Gamma k=0.91; Beta versus Gamma k=0.91). Conclusion: Relying on either H&E staining or TFF2-IHC, pathologists assess PPM consistently. (C) 2020 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [1] INTRA- AND INTER-OBSERVER VARIATIONS IN ASSESSMENT OF EMPHYSEMA
    THURLBEC.WM
    HOROWITZ, I
    SIEMIATY.J
    DUNNILL, MS
    MAISEL, JC
    PRATT, P
    RYDER, R
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1969, 18 (04): : 646 - &
  • [2] Intra- and inter-observer agreement in histological assessment of canine soft tissue sarcoma
    Yap, F. W.
    Rasotto, R.
    Priestnall, S. L.
    Parsons, K. J.
    Stewart, J.
    VETERINARY AND COMPARATIVE ONCOLOGY, 2017, 15 (04) : 1553 - 1557
  • [3] Intra- and inter-observer agreement for the histological diagnosis of Aberrant Crypt Foci (ACF)
    Jimeno, M.
    Cuatrecasas, M.
    Quintanilla, I.
    Lopez Ceron, M.
    Rodriguez de Miguel, C.
    Camps, J.
    Balaguer, F.
    Llach, J.
    Pellise, M.
    VIRCHOWS ARCHIV, 2014, 465 : S232 - S232
  • [4] Ultrasound Assessment of Pubertal Breast Development: Intra- and Inter-observer Agreement
    Bruserud, Ingvild
    Mathieu, Roelants
    Oehme, Ninnie
    Eide, Geir Egil
    Bjerknes, Robert
    Rosendahl, Karen
    Juiliusson, Petur
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 90 : 511 - 511
  • [5] Classification of Minor Stroke: Intra- and Inter-Observer Reliability
    Selvarajah, Johann R.
    Glaves, Matthew
    Wainwright, Jane
    Jha, Animesh
    Vail, Andy
    Tyrrell, Pippa J.
    CEREBROVASCULAR DISEASES, 2009, 27 (03) : 209 - 214
  • [6] Intra- and inter-observer reliability in anthropometric measurements in children
    S Stomfai
    W Ahrens
    K Bammann
    É Kovács
    S Mårild
    N Michels
    L A Moreno
    H Pohlabeln
    A Siani
    M Tornaritis
    T Veidebaum
    D Molnár
    International Journal of Obesity, 2011, 35 : S45 - S51
  • [7] Intra- and inter-observer reliability in anthropometric measurements in children
    Stomfai, S.
    Ahrens, W.
    Bammann, K.
    Kovacs, E.
    Marild, S.
    Michels, N.
    Moreno, L. A.
    Pohlabeln, H.
    Siani, A.
    Tornaritis, M.
    Veidebaum, T.
    Molnar, D.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S45 - S51
  • [8] Intra- and inter-observer variability of functional MR urography (fMRU) assessment in children
    Dmitry Khrichenko
    David Saul
    Melkamu Adeb
    Camilo Jaimes
    Khalil N. Betts
    Stephanie M. Barron
    J. Christopher Edgar
    Sarah M. Lambert
    Pasquale Casale
    Kassa Darge
    Pediatric Radiology, 2016, 46 : 666 - 673
  • [9] Intra- and inter-observer analysis in the morphological assessment of early-stage embryos
    Paternot, Goedele
    Devroe, Johanna
    Debrock, Sophie
    D'Hooghe, Thomas M.
    Spiessens, Carl
    REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2009, 7 : 105
  • [10] Intra- and inter-observer analysis in the morphological assessment of early-stage embryos
    Goedele Paternot
    Johanna Devroe
    Sophie Debrock
    Thomas M D'Hooghe
    Carl Spiessens
    Reproductive Biology and Endocrinology, 7