CT in Patients With External Fixation for Complex Lower Extremity Fractures: Impact of Iterative Metal Artifact Reduction Techniques on Metal Artifact Burden and Subjective Quality

被引:4
|
作者
Brendlin, Andreas Stefan [1 ]
Reinert, Christian Philipp [1 ]
Baumgartner, Heiko [2 ]
Bongers, Malte Niklas [1 ]
Thomas, Christoph [3 ]
Afat, Saif [1 ]
Springer, Fabian [1 ,4 ]
Almansour, Haidara [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tubingen, Dept Trauma & Reconstruct Surg, BG Unfallklin, Tubingen, Germany
[3] Radiologikum Krefeld, Krefeld, Germany
[4] Eberhard Karls Univ Tubingen, Dept Diagnost Radiol, BG Unfallklin, Tubingen, Germany
关键词
artifacts; CT; external fixation; fracture; image reconstruction; monotube;
D O I
10.2214/AJR.21.26442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. Lower extremity external fixators have complex geometries that induce pronounced metal artifact on CT. Iterative metal artifact reduction (iMAR) algorithms help reduce such artifact, although no dedicated iMAR preset exists for external fixators. OBJECTIVE. The purpose of our study was to compare iMAR presets for CT examinations in terms of quantitative metal artifact burden and subjective image quality in patients with external fixators for complex lower extremity fractures. METHODS. This retrospective study included 72 CT examinations in 56 patients (20 women, 36 men; mean age, 56 +/- 18 [SD] years) with lower extremity external fixators (regular, hybrid, or monotube). Examinations were reconstructed without iMAR (hereafter referred to as "noMAR") and with three iMAR presets (iMAR(spine), iMAR(hip), iMAR(extremity)). A radiology resident quantified metal artifact burden using software. Two radiology residents independently assessed overall image quality and diagnostic confidence using 4-point scales (4 = excellent [highest quality or highest confidence]). Techniques were compared using Bonferroni-corrected post hoc tests. Interreader agreement was assessed by intraclass correlation coefficients (ICCs). A post hoc multinomial regression model was used for predicting overall image quality. RESULTS. Mean quantitative metal artifact burden was 100,816 +/- 45,558 for noMAR, 88,889 +/- 44,028 for iMAR(spine), 82,295 +/- 41,983 for iMAR(hip), and 81,956 +/- 41,890 for iMAR(extremity). Overall image quality yielded an ICC of 0.94 or greater. Using pooled reader data, median overall image quality score for the regular fixator was 2 (noMAR), 3 (iMAR(spine) and iMAR(hip)), and 4 (iMAR(extremity)); for the hybrid fixator, 1 (noMAR), 2 (iMAR(s)(pine)), and 3 (iMAR(hip) and iMAR(extremity)); and for the monotube fixator, 2 (noMAR), 3 (iMAR(spine) and iMAR(h)(ip)), and 4 (iMAR(extremity)). Metal artifact burden was lower and overall image quality was higher (p < .05) for iMAR(hip) and iMAR(extremity) than noMAR and iMAR(spine) for all fixators (aside from image quality of iMAR(hip) and iMAR(extremity) vs iMAR(spine) for regular fixators) but were not different (all, p > .05) between iMAR(hip) and iMAR(extremity). Median diagnostic confidence was 4 for all fixators and reconstructions. Independent predictors of overall quality relative to noMAR were iMAR(s)(pine) (odds ratio [OR] = 1.92-5.51), iMAR(hip) (OR = 5.56-31.10), and iMAR(extremity) (OR = 7.07-38.21). All iMAR presets introduced new reconstruction artifacts for all examinations for both readers. CONCLUSION. For the three fixator types, iMAR(hip) and iMAR(extremity) achieved greatest metal artifact burden reduction and highest subjective image quality, although both introduced new reconstruction artifacts. CLINICAL IMPACT. CT using the two identified iMAR presets may facilitate perioperative management of external fixators.
引用
收藏
页码:300 / 309
页数:10
相关论文
共 50 条
  • [41] Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation
    Kaewlek, Titipong
    Koolpiruck, Diew
    Thongvigitmanee, Saowapak
    Mongkolsuk, Manus
    Thammakittiphan, Sastrawut
    Tritrakarn, Siri-on
    Chiewvit, Pipat
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (06) : 649 - 666
  • [42] Image quality and metal artifact reduction in total hip arthroplasty CT: deep learning-based algorithm versus virtual monoenergetic imaging and orthopedic metal artifact reduction
    Mark Selles
    Ruud H. H. Wellenberg
    Derk J. Slotman
    Ingrid M. Nijholt
    Jochen A. C. van Osch
    Kees F. van Dijke
    Mario Maas
    Martijn F. Boomsma
    European Radiology Experimental, 8
  • [43] Image quality and metal artifact reduction in total hip arthroplasty CT: deep learning-based algorithm versus virtual monoenergetic imaging and orthopedic metal artifact reduction
    Selles, Mark
    Wellenberg, Ruud H. H.
    Slotman, Derk J.
    Nijholt, Ingrid M.
    van Osch, Jochen A. C.
    van Dijke, Kees F.
    Maas, Mario
    Boomsma, Martijn F.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [44] Comparison of IMAR and AiMAR Techniques for Metal Artifact Reduction in CT-Guided Microwave Ablations
    Jacobsen, M.
    Thompson, E.
    Liu, X.
    Odisio, B.
    Cressman, E.
    Layman, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E521 - E521
  • [45] Impact of different metal artifact reduction techniques on attenuation correction in 18F-FDG PET/CT examinations
    Martin, Ole
    Aissa, Joel
    Boos, Johannes
    Wingendorf, Katrin
    Latz, David
    Buchbender, Christian
    Gaspers, Susanne
    Antke, Christina
    Sedlmair, Martin
    Antoch, Gerald
    Schaarschmidt, Benedikt M.
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1105):
  • [46] Impact of different iterative metal artifact reduction (iMAR) algorithms on PET/CT attenuation correction in artifacts after port implantation
    Martin, O.
    Boos, J.
    Aissa, J.
    Heusch, P.
    Antoch, G.
    Gaspers, S.
    Antke, C.
    Schaarschmidt, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S701 - S701
  • [47] Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling—improved image quality by iterative metal artifact reduction
    Georg Bier
    Malte Niklas Bongers
    Johann-Martin Hempel
    Anja Örgel
    Till-Karsten Hauser
    Ulrike Ernemann
    Florian Hennersdorf
    Neuroradiology, 2017, 59 : 649 - 654
  • [48] Photon-counting detector computed tomography for metal artifact reduction: a comparative study of different artifact reduction techniques in patients with orthopedic implants
    Pallasch, Fabian Bernhard
    Rau, Alexander
    Reisert, Marco
    Rau, Stephan
    Diallo, Thierno
    Stein, Thomas
    Faby, Sebastian
    Bamberg, Fabian
    Weiss, Jakob
    RADIOLOGIA MEDICA, 2024, 129 (06): : 890 - 900
  • [49] Evaluation of Surrogate Data Quality in Sinogram-Based CT Metal-Artifact Reduction
    Oehler, May
    Kratz, Baerbel
    Knopp, Tobias
    Mueller, Jan
    Buzug, Thorsten M.
    IMAGE RECONSTRUCTION FROM INCOMPLETE DATA V, 2008, 7076
  • [50] Dosimetric impact of CT metal artifact reduction for spinal implants in stereotactic body radiotherapy planning
    Li, Bin
    Huang, Jiexing
    Ruan, Junjie
    Peng, Qinghe
    Huang, Sijuan
    Li, Yunfei
    Li, Fanghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 8290 - 8302