CT in Patients With External Fixation for Complex Lower Extremity Fractures: Impact of Iterative Metal Artifact Reduction Techniques on Metal Artifact Burden and Subjective Quality

被引:4
|
作者
Brendlin, Andreas Stefan [1 ]
Reinert, Christian Philipp [1 ]
Baumgartner, Heiko [2 ]
Bongers, Malte Niklas [1 ]
Thomas, Christoph [3 ]
Afat, Saif [1 ]
Springer, Fabian [1 ,4 ]
Almansour, Haidara [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tubingen, Dept Trauma & Reconstruct Surg, BG Unfallklin, Tubingen, Germany
[3] Radiologikum Krefeld, Krefeld, Germany
[4] Eberhard Karls Univ Tubingen, Dept Diagnost Radiol, BG Unfallklin, Tubingen, Germany
关键词
artifacts; CT; external fixation; fracture; image reconstruction; monotube;
D O I
10.2214/AJR.21.26442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. Lower extremity external fixators have complex geometries that induce pronounced metal artifact on CT. Iterative metal artifact reduction (iMAR) algorithms help reduce such artifact, although no dedicated iMAR preset exists for external fixators. OBJECTIVE. The purpose of our study was to compare iMAR presets for CT examinations in terms of quantitative metal artifact burden and subjective image quality in patients with external fixators for complex lower extremity fractures. METHODS. This retrospective study included 72 CT examinations in 56 patients (20 women, 36 men; mean age, 56 +/- 18 [SD] years) with lower extremity external fixators (regular, hybrid, or monotube). Examinations were reconstructed without iMAR (hereafter referred to as "noMAR") and with three iMAR presets (iMAR(spine), iMAR(hip), iMAR(extremity)). A radiology resident quantified metal artifact burden using software. Two radiology residents independently assessed overall image quality and diagnostic confidence using 4-point scales (4 = excellent [highest quality or highest confidence]). Techniques were compared using Bonferroni-corrected post hoc tests. Interreader agreement was assessed by intraclass correlation coefficients (ICCs). A post hoc multinomial regression model was used for predicting overall image quality. RESULTS. Mean quantitative metal artifact burden was 100,816 +/- 45,558 for noMAR, 88,889 +/- 44,028 for iMAR(spine), 82,295 +/- 41,983 for iMAR(hip), and 81,956 +/- 41,890 for iMAR(extremity). Overall image quality yielded an ICC of 0.94 or greater. Using pooled reader data, median overall image quality score for the regular fixator was 2 (noMAR), 3 (iMAR(spine) and iMAR(hip)), and 4 (iMAR(extremity)); for the hybrid fixator, 1 (noMAR), 2 (iMAR(s)(pine)), and 3 (iMAR(hip) and iMAR(extremity)); and for the monotube fixator, 2 (noMAR), 3 (iMAR(spine) and iMAR(h)(ip)), and 4 (iMAR(extremity)). Metal artifact burden was lower and overall image quality was higher (p < .05) for iMAR(hip) and iMAR(extremity) than noMAR and iMAR(spine) for all fixators (aside from image quality of iMAR(hip) and iMAR(extremity) vs iMAR(spine) for regular fixators) but were not different (all, p > .05) between iMAR(hip) and iMAR(extremity). Median diagnostic confidence was 4 for all fixators and reconstructions. Independent predictors of overall quality relative to noMAR were iMAR(s)(pine) (odds ratio [OR] = 1.92-5.51), iMAR(hip) (OR = 5.56-31.10), and iMAR(extremity) (OR = 7.07-38.21). All iMAR presets introduced new reconstruction artifacts for all examinations for both readers. CONCLUSION. For the three fixator types, iMAR(hip) and iMAR(extremity) achieved greatest metal artifact burden reduction and highest subjective image quality, although both introduced new reconstruction artifacts. CLINICAL IMPACT. CT using the two identified iMAR presets may facilitate perioperative management of external fixators.
引用
收藏
页码:300 / 309
页数:10
相关论文
共 50 条
  • [31] Evaluation of the quality of CT images acquired with smart metal artifact reduction software
    Zhou, Peng
    Zhang, Chunling
    Gao, Zhen
    Cai, Wangshu
    Yan, Deyue
    Wei, Zhaolong
    OPEN LIFE SCIENCES, 2018, 13 (01): : 155 - 162
  • [32] Metal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction Algorithm
    Nagayama, Y.
    Tanoue, S.
    Oda, S.
    Sakabe, D.
    Emoto, T.
    Kidoh, M.
    Uetani, H.
    Sasao, A.
    Nakaura, T.
    Ikeda, O.
    Yamada, K.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (02) : 231 - 237
  • [33] Potential of computed tomography with iterative metal artifact reduction algorithm for proton therapy of patients with metal implants
    Belloni, S.
    Peroni, M.
    Bolsi, A.
    Niemann, T.
    Engelhardt, D.
    Fachouri, N.
    Perrin, R.
    Walser, M.
    Fattori, G.
    Kubik-Huch, R. A.
    Lomax, A. J.
    Weber, D. C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 843 - 843
  • [34] The value of metal artifact reduction and iterative algorithms in dual energy CT angiography in patients after complex endovascular aortic aneurysm repair
    Kazimierczak, Wojciech
    Nowak, Ewa
    Kazimierczak, Natalia
    Jankowski, Tomasz
    Jankowska, Agnieszka
    Serafin, Zbigniew
    HELIYON, 2023, 9 (10)
  • [35] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [36] Impact of different iterative metal artifact reduction (iMAR) algorithms on PET/CT attenuation correction after port implementation
    Martin, Ole
    Boos, Johannes
    Aissa, Joel
    Vay, Christian
    Heusch, Philipp
    Gaspers, Susanne
    Antke, Christina
    Sedlmair, Martin
    Antoch, Gerald
    Schaarschmidt, Benedikt M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [37] Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?
    An De Crop
    Jan Casselman
    Tom Van Hoof
    Melissa Dierens
    Elke Vereecke
    Nicolas Bossu
    Jaime Pamplona
    Katharina D’Herde
    Hubert Thierens
    Klaus Bacher
    Neuroradiology, 2015, 57 : 841 - 849
  • [38] Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?
    De Crop, An
    Casselman, Jan
    Van Hoof, Tom
    Dierens, Melissa
    Vereecke, Elke
    Bossu, Nicolas
    Pamplona, Jaime
    D'Herde, Katharina
    Thierens, Hubert
    Bacher, Klaus
    NEURORADIOLOGY, 2015, 57 (08) : 841 - 849
  • [39] Combination of Iterative Metal Artifact Reduction and Virtual Monoenergetic Reconstruction Using Split-Filter Dual-Energy CT in Patients With Dental Artifact on Head and Neck CT
    Schmidt, Alexander Marcel Alfred
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Gruschwitz, Philipp
    Knarr, Jonas
    Huflage, Henner
    Bley, Thorsten Alexander
    Kosmala, Aleksander
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 716 - 727
  • [40] Evaluation of the Impact of Using TOF Technique on Metal Artifact Reduction in PET/CT Images
    Sharifpour, R.
    Ghafarian, P.
    Ay, M. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S363 - S364