CT in Patients With External Fixation for Complex Lower Extremity Fractures: Impact of Iterative Metal Artifact Reduction Techniques on Metal Artifact Burden and Subjective Quality

被引:4
|
作者
Brendlin, Andreas Stefan [1 ]
Reinert, Christian Philipp [1 ]
Baumgartner, Heiko [2 ]
Bongers, Malte Niklas [1 ]
Thomas, Christoph [3 ]
Afat, Saif [1 ]
Springer, Fabian [1 ,4 ]
Almansour, Haidara [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Eberhard Karls Univ Tubingen, Dept Trauma & Reconstruct Surg, BG Unfallklin, Tubingen, Germany
[3] Radiologikum Krefeld, Krefeld, Germany
[4] Eberhard Karls Univ Tubingen, Dept Diagnost Radiol, BG Unfallklin, Tubingen, Germany
关键词
artifacts; CT; external fixation; fracture; image reconstruction; monotube;
D O I
10.2214/AJR.21.26442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. Lower extremity external fixators have complex geometries that induce pronounced metal artifact on CT. Iterative metal artifact reduction (iMAR) algorithms help reduce such artifact, although no dedicated iMAR preset exists for external fixators. OBJECTIVE. The purpose of our study was to compare iMAR presets for CT examinations in terms of quantitative metal artifact burden and subjective image quality in patients with external fixators for complex lower extremity fractures. METHODS. This retrospective study included 72 CT examinations in 56 patients (20 women, 36 men; mean age, 56 +/- 18 [SD] years) with lower extremity external fixators (regular, hybrid, or monotube). Examinations were reconstructed without iMAR (hereafter referred to as "noMAR") and with three iMAR presets (iMAR(spine), iMAR(hip), iMAR(extremity)). A radiology resident quantified metal artifact burden using software. Two radiology residents independently assessed overall image quality and diagnostic confidence using 4-point scales (4 = excellent [highest quality or highest confidence]). Techniques were compared using Bonferroni-corrected post hoc tests. Interreader agreement was assessed by intraclass correlation coefficients (ICCs). A post hoc multinomial regression model was used for predicting overall image quality. RESULTS. Mean quantitative metal artifact burden was 100,816 +/- 45,558 for noMAR, 88,889 +/- 44,028 for iMAR(spine), 82,295 +/- 41,983 for iMAR(hip), and 81,956 +/- 41,890 for iMAR(extremity). Overall image quality yielded an ICC of 0.94 or greater. Using pooled reader data, median overall image quality score for the regular fixator was 2 (noMAR), 3 (iMAR(spine) and iMAR(hip)), and 4 (iMAR(extremity)); for the hybrid fixator, 1 (noMAR), 2 (iMAR(s)(pine)), and 3 (iMAR(hip) and iMAR(extremity)); and for the monotube fixator, 2 (noMAR), 3 (iMAR(spine) and iMAR(h)(ip)), and 4 (iMAR(extremity)). Metal artifact burden was lower and overall image quality was higher (p < .05) for iMAR(hip) and iMAR(extremity) than noMAR and iMAR(spine) for all fixators (aside from image quality of iMAR(hip) and iMAR(extremity) vs iMAR(spine) for regular fixators) but were not different (all, p > .05) between iMAR(hip) and iMAR(extremity). Median diagnostic confidence was 4 for all fixators and reconstructions. Independent predictors of overall quality relative to noMAR were iMAR(s)(pine) (odds ratio [OR] = 1.92-5.51), iMAR(hip) (OR = 5.56-31.10), and iMAR(extremity) (OR = 7.07-38.21). All iMAR presets introduced new reconstruction artifacts for all examinations for both readers. CONCLUSION. For the three fixator types, iMAR(hip) and iMAR(extremity) achieved greatest metal artifact burden reduction and highest subjective image quality, although both introduced new reconstruction artifacts. CLINICAL IMPACT. CT using the two identified iMAR presets may facilitate perioperative management of external fixators.
引用
收藏
页码:300 / 309
页数:10
相关论文
共 50 条
  • [21] Clinical Evaluation of the Iterative Metal Artifact Reduction Algorithm for CT Simulation in Radiotherapy
    Axente, M.
    Lee, K.
    Paidi, A.
    Bani-Hashemi, A.
    Hristov, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy
    Axente, Marian
    Paidi, Ajay
    Von Eyben, Rie
    Zeng, Chuan
    Bani-Hashemi, Ali
    Krauss, Andreas
    Hristov, Dimitre
    MEDICAL PHYSICS, 2015, 42 (03) : 1170 - 1183
  • [23] Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants
    Bolstad, Kirsten
    Flatabo, Silje
    Aadnevik, Daniel
    Dalehaug, Ingvild
    Vetti, Nils
    ACTA RADIOLOGICA, 2018, 59 (09) : 1110 - 1118
  • [24] IRDNet: Iterative Relation-Based Dual-Domain Network via Metal Artifact Feature Guidance for CT Metal Artifact Reduction
    Wang, Huamin
    Yang, Shuo
    Bai, Xiao
    Wang, Zhe
    Wu, Jiayi
    Lv, Yang
    Cao, Guohua
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (08) : 959 - 972
  • [25] Combining dual-tree complex wavelets and multiresolution in iterative CT reconstruction with application to metal artifact reduction
    Defne Us
    Ulla Ruotsalainen
    Sampsa Pursiainen
    BioMedical Engineering OnLine, 18
  • [26] CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?
    Kotsenas, A. L.
    Michalak, G. J.
    DeLone, D. R.
    Diehn, F. E.
    Grant, K.
    Halaweish, A. F.
    Krauss, A.
    Raupach, R.
    Schmidt, B.
    McCollough, C. H.
    Fletcher, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) : 2184 - 2190
  • [27] Combining dual-tree complex wavelets and multiresolution in iterative CT reconstruction with application to metal artifact reduction
    Us, Defne
    Ruotsalainen, Ulla
    Pursiainen, Sampsa
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (01)
  • [28] ITERATIVE DEBLURRING OF CT IMAGE-RESTORATION, METAL ARTIFACT REDUCTION AND LOCAL RECONSTRUCTION
    WANG, G
    SNYDER, DL
    VANNIER, MW
    RADIOLOGY, 1995, 197 : 291 - 291
  • [29] Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses
    Payam Mohammadinejad
    Francis I. Baffour
    Mark C. Adkins
    Lifeng Yu
    Cynthia H. McCollough
    Joel G. Fletcher
    Katrina N. Glazebrook
    Skeletal Radiology, 2021, 50 : 51 - 58
  • [30] Benefits of iterative metal artifact reduction and dual-energy CT towards mitigating artifact in the setting of total shoulder prostheses
    Mohammadinejad, Payam
    Baffour, Francis, I
    Adkins, Mark C.
    Yu, Lifeng
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Glazebrook, Katrina N.
    SKELETAL RADIOLOGY, 2021, 50 (01) : 51 - 58