Rapid and direct analysis of statins in human plasma by column-switching liquid chromatography with restricted-access material

被引:24
|
作者
Fagundes, Vinicius Freire [1 ]
Leite, Camila Prado [1 ]
Pianetti, Gerson Antonio [1 ]
Fernandes, Christian [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Prod Farmaceut, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Statins; Column-switching; Restricted access material; Online sample preparation; TANDEM MASS-SPECTROMETRY; LC-MS/MS; SIMVASTATIN; QUANTIFICATION; PRAVASTATIN; LOVASTATIN; HPLC; ACID; ROSUVASTATIN; PITAVASTATIN;
D O I
10.1016/j.jchromb.2013.12.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents the development of a column-switching liquid chromatographic method with direct injection of human plasma for simultaneous determination of four statins (lovastatin, pravastatin, rosuvastatin and simvastatin), the main class of drugs used in the treatment of hyperlipidemia. By using a C18 (30 mm x 4.6 mm, 15 mu m) a lab made bovine serum albumin restricted access material (RAM) column was prepared and compared with a commercial alquil-diol silica RAM column (C18, 25 mm x 4.0 mm, 25 mu m) in terms of their protein exclusion capacity and micromolecules retention. Foreflush and backflush modes were compared for both RAM columns to the number of theoretical plates, asymmetry, resolution and chromatographic run time. The developed method was validated in the range from 125 to 876 ng mL(-1) for lovastatin, rosuvastatin and simvastatin, and from 500 to 2000 ng mL(-1) for pravastatin, presenting selectivity, precision and accuracy intra and inter-run. Total analysis time (sample preparation and chromatographic separation) was only 16 min when the backflush mode was employed in the column-switching system. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [1] Direct analysis of clomipramine in human plasma by microbore high performance liquid chromatography with column-switching
    Lee, HM
    Jeong, CK
    Choi, SJ
    Yoon, BM
    Na, DH
    Lee, KC
    Lee, HS
    CHROMATOGRAPHIA, 2000, 51 (5-6) : 353 - 356
  • [2] Evaluation of liquid chromatographic behavior of restricted-access media precolumns in the course of direct injection of large volumes of plasma samples in column-switching systems
    Yu, ZX
    Westerlund, D
    Boos, KS
    JOURNAL OF CHROMATOGRAPHY B, 1997, 704 (1-2): : 53 - 62
  • [3] Direct analysis of clomipramine in human plasma by microbore high performance liquid chromatography with column-switching
    H. M. Lee
    C. K. Jeong
    S. J. Choi
    B. M. Yoon
    D. H. Na
    K. C. Lee
    H. S. Lee
    Chromatographia, 2000, 51 : 353 - 356
  • [4] Direct analysis of artemisinin in plasma and saliva using coupled-column high-performance liquid chromatography with a restricted-access material pre-column
    Gordi, T
    Nielsen, E
    Yu, ZX
    Westerlund, D
    Ashton, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01): : 155 - 162
  • [5] Analysis of coenzyme Q10 in human plasma by column-switching liquid chromatography
    Ping, JA
    Wu, MH
    Zheng, YF
    Wang, C
    Li, YH
    Xin, JA
    Xu, GW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02): : 297 - 301
  • [6] Application of the restricted-access precolumn packing material alkyl-diol silica in a column-switching system for the determination of ketoprofen enantiomers in horse plasma
    Baeyens, WRG
    Van der Weken, G
    Haustraete, J
    Aboul-Enein, HY
    Corveleyn, S
    Remon, JP
    García-Campaña, AM
    Deprez, P
    JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) : 153 - 161
  • [7] Discovery of xanthine oxidase inhibitors from a complex mixture using an online, restricted-access material coupled with column-switching liquid chromatography with a diode-array detection system
    De-qiang Li
    Jing Zhao
    Shao-ping Li
    Qing-wen Zhang
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1975 - 1984
  • [8] Discovery of xanthine oxidase inhibitors from a complex mixture using an online, restricted-access material coupled with column-switching liquid chromatography with a diode-array detection system
    Li, De-qiang
    Zhao, Jing
    Li, Shao-ping
    Zhang, Qing-wen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (07) : 1975 - 1984
  • [9] Using restricted-access materials and column switching in high-performance liquid chromatography for direct analysis of biologically-active compounds in complex matrices
    Sadilek, Petr
    Satinsky, Dalibor
    Solich, Petr
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (05) : 375 - 384
  • [10] A COLUMN-SWITCHING LIQUID-CHROMATOGRAPHY ASSAY FOR THE ANALYSIS OF CARBOPLATIN IN PLASMA ULTRAFILTRATE
    ALLSOPP, MA
    SEWELL, GJ
    ROWLAND, CG
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (05) : 375 - 381