Discovery of xanthine oxidase inhibitors from a complex mixture using an online, restricted-access material coupled with column-switching liquid chromatography with a diode-array detection system

被引:0
|
作者
De-qiang Li
Jing Zhao
Shao-ping Li
Qing-wen Zhang
机构
[1] University of Macau,State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences
来源
关键词
Xanthine oxidase inhibitors; Restricted-access material; Column switching; Liquid chromatography;
D O I
暂无
中图分类号
学科分类号
摘要
To find potential lead compounds for antigout drug discovery, an automated online, restricted-access material coupled with column-switching liquid chromatography with a diode-array detection (RAM–LC–DAD) system was developed for screening of xanthine oxidase (XO) inhibitors and their affinity rankings in complex mixtures. The system was first evaluated by analyzing a mixture of six compounds with known inhibition of XO. Nonspecific binding to the denatured XO was investigated and used as the control for screening. Subsequently, the newly developed system was applied to screening of a natural product, Oroxylum indicum extract, and four compounds which could specifically interact with XO were found and identified as oroxin B, oroxin A, baicalin, and baicalein. The results were verified by a competitive binding test using the known competitive inhibitor allopurinol and were further validated by an inhibition assay in vitro. The online RAM–LC–DAD system developed was shown to be a simple and effective strategy for the rapid screening of bioactive compounds from a complex mixture.
引用
收藏
页码:1975 / 1984
页数:9
相关论文
共 16 条
  • [1] Discovery of xanthine oxidase inhibitors from a complex mixture using an online, restricted-access material coupled with column-switching liquid chromatography with a diode-array detection system
    Li, De-qiang
    Zhao, Jing
    Li, Shao-ping
    Zhang, Qing-wen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (07) : 1975 - 1984
  • [2] Rapid and direct analysis of statins in human plasma by column-switching liquid chromatography with restricted-access material
    Fagundes, Vinicius Freire
    Leite, Camila Prado
    Pianetti, Gerson Antonio
    Fernandes, Christian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 8 - 16
  • [3] Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection
    Brunetto, MR
    Cayama, YD
    García, LG
    Gallignani, M
    Obando, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) : 115 - 120
  • [4] Online enrichment ability of restricted-access column coupled with high performance liquid chromatography by column switching technique for benazepril hydrochloride
    Zhang Xiaohui
    Wang Rong
    Xie Hua
    Yin Qiang
    Li Xiaoyun
    Jia Zhengping
    Wu Xiaoyu
    Zhang Juanhong
    Li Wenbin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (05) : 451 - 455
  • [5] Direct analysis of artemisinin in plasma and saliva using coupled-column high-performance liquid chromatography with a restricted-access material pre-column
    Gordi, T
    Nielsen, E
    Yu, ZX
    Westerlund, D
    Ashton, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 742 (01): : 155 - 162
  • [6] Using restricted-access materials and column switching in high-performance liquid chromatography for direct analysis of biologically-active compounds in complex matrices
    Sadilek, Petr
    Satinsky, Dalibor
    Solich, Petr
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (05) : 375 - 384
  • [7] Direct extraction of tetracyclines from bovine milk using restricted access carbon nanotubes in a column switching liquid chromatography system
    de Faria, Henrique Dipe
    Rosa, Mariana Azevedo
    Silveira, Alberto Thalison
    Figueiredo, Eduardo Costa
    FOOD CHEMISTRY, 2017, 225 : 98 - 106
  • [8] High-performance liquid chromatography coupled with post-column dual-bioactivity assay for simultaneous screening of xanthine oxidase inhibitors and free radical scavengers from complex mixture
    Li, D. Q.
    Zhao, J.
    Li, S. P.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1345 : 50 - 56
  • [9] Online extraction of antihypertensive drugs and their metabolites from untreated human serum samples using restricted access carbon nanotubes in a column switching liquid chromatography system
    de Faria, Henrique Dipe
    Bueno, Carolina Tosin
    Krieger, Jose Eduardo
    Krieger, Eduardo Moacyr
    Pereira, Alexandre Costa
    Junior Lima Santos, Paulo Caleb
    Figueiredo, Eduardo Costa
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1528 : 41 - 52
  • [10] Determination of sulfonamides in bovine milk with column-switching high performance liquid chromatography using surface imprinted silica with hydrophilic external layer as restricted access and selective extraction material
    Xu, Wenjuan
    Su, Shufang
    Jiang, Ping
    Wang, Huaisong
    Dong, Xiangchao
    Zhang, Min
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (46) : 7198 - 7207