Rapid and direct analysis of statins in human plasma by column-switching liquid chromatography with restricted-access material

被引:24
|
作者
Fagundes, Vinicius Freire [1 ]
Leite, Camila Prado [1 ]
Pianetti, Gerson Antonio [1 ]
Fernandes, Christian [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Prod Farmaceut, BR-31270901 Belo Horizonte, MG, Brazil
关键词
Statins; Column-switching; Restricted access material; Online sample preparation; TANDEM MASS-SPECTROMETRY; LC-MS/MS; SIMVASTATIN; QUANTIFICATION; PRAVASTATIN; LOVASTATIN; HPLC; ACID; ROSUVASTATIN; PITAVASTATIN;
D O I
10.1016/j.jchromb.2013.12.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study presents the development of a column-switching liquid chromatographic method with direct injection of human plasma for simultaneous determination of four statins (lovastatin, pravastatin, rosuvastatin and simvastatin), the main class of drugs used in the treatment of hyperlipidemia. By using a C18 (30 mm x 4.6 mm, 15 mu m) a lab made bovine serum albumin restricted access material (RAM) column was prepared and compared with a commercial alquil-diol silica RAM column (C18, 25 mm x 4.0 mm, 25 mu m) in terms of their protein exclusion capacity and micromolecules retention. Foreflush and backflush modes were compared for both RAM columns to the number of theoretical plates, asymmetry, resolution and chromatographic run time. The developed method was validated in the range from 125 to 876 ng mL(-1) for lovastatin, rosuvastatin and simvastatin, and from 500 to 2000 ng mL(-1) for pravastatin, presenting selectivity, precision and accuracy intra and inter-run. Total analysis time (sample preparation and chromatographic separation) was only 16 min when the backflush mode was employed in the column-switching system. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [41] Liquid chromatography determination of 10-hydroxycamptothecin in human serum by a column-switching system containing a pre-column with restricted access media and its application to a clinical pharmacokinetic study
    Ma, J
    Jia, ZP
    Zhang, Q
    Fan, JJ
    Jiang, NX
    Wang, R
    Xie, H
    Wang, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01): : 195 - 200
  • [42] Direct analysis of indomethacin in rat plasma using a column-switching high-performance liquid chromatographic system
    Liu, SC
    Kamijo, M
    Takayasu, T
    Takayama, S
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 53 - 60
  • [43] DETERMINATION OF MANIDIPINE ENANTIOMERS IN HUMAN SERUM USING CHIRAL CHROMATOGRAPHY AND COLUMN-SWITCHING LIQUID-CHROMATOGRAPHY
    YAMAGUCHI, M
    YAMASHITA, K
    AOKI, I
    TABATA, T
    HIRAI, SI
    YASHIKI, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01): : 123 - 129
  • [44] DETERMINATION OF OXYTETRACYCLINE IN FISH PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN-SWITCHING
    EIVINDVIK, K
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 3061 - 3071
  • [45] Rapid pharmacokinetic screening of salbutamol in plasma samples by column-switching high-performance liquid chromatography electrospray mass spectrometry
    Schmeer, K
    Sauter, T
    Schmid, J
    JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) : 67 - 72
  • [46] Rapid column-switching liquid chromatography/mass spectrometric assay for DHEA-sulfate in the plasma of patients with Alzheimer's disease
    Cho, Sung-Hee
    Jung, Byung Hwa
    Lee, Won-Yong
    Chung, Bong Chul
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (10) : 1093 - 1097
  • [47] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [48] Rapid analysis of pesticides causing acute poisoning in patients by high-performance liquid chromatography with column-switching technique
    Mori, H
    Nagase, H
    Okada, K
    Takada, K
    Nakamura, M
    Yamazaki, F
    JOURNAL OF HEALTH SCIENCE, 1999, 45 (05) : 282 - 288
  • [49] DIRECT DETERMINATION OF E2020 ENANTIOMERS IN PLASMA BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND COLUMN-SWITCHING TECHNIQUES
    MATSUI, K
    ODA, Y
    OHE, H
    TANAKA, S
    ASAKAWA, N
    JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) : 209 - 218
  • [50] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230