High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence

被引:47
|
作者
Chen, Albert P.
Cunningham, Charles H.
Kurhanewicz, John
Xu, Duan
Hurd, Ralph E.
Pauly, John M.
Carvajal, Lucas
Karpodinis, Kostas
Vigneron, Daniel B. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] GE Hlth Care Technol, Menlo Pk, CA 94025 USA
关键词
spectroscopic imaging; prostate cancer; high field; MLEV-PRESS;
D O I
10.1016/j.mri.2006.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 3 T MLEV-point-resolved spectroscopy (PRESS) sequence employing optimized spectral-spatial and very selective outer-voxel suppression pulses was tested in 25 prostate cancer patients. At an echo time of 85 ins, the MLEV-PRESS sequence resulted in maximally upright inner resonances and minimal outer resonances of the citrate doublet of doublets. Magnetic resonance spectroscopic imaging (MRSI) exams performed at both 3 and 1.5 T for 10 patients demonstrated a 2.08 +/- 0.36-fold increase in signal-to-noise ratio (SNR) at 3 T as compared with 1.5 T for the center citrate resonances. This permitted the acquisition of MRSI data with a nominal spatial resolution of 0.16 cm(3) at 3 T with similar SNR as the 0.34-cm(3) data acquired at 1.5 T. Due to the twofold increase in spectral resolution at 3 T and the improved magnetic field homogeneity provided by susceptibility-matched endorectal coils, the choline resonance was better resolved from polyamine and creatine resonances as compared with 1.5 T spectra. In prostate cancer patients, the elevation of choline and the reduction of polyamines were more clearly observed at 3 T, as compared with 1.5 T MRSI. The increased SNR and corresponding spatial resolution obtainable at 3 T reduced partial volume effects and allowed improved detection of the presence and extent of abnormal metabolite levels in prostate cancer patients, as compared with 1.5 T MRSI. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 50 条
  • [21] Topographic Analysis of the Inferior Parietal Lobule in High-Resolution 3D MR Imaging
    Kiriyama, I.
    Miki, H.
    Kikuchi, K.
    Ohue, S.
    Matsuda, S.
    Mochizuki, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (03) : 520 - 524
  • [22] On the road to high-resolution 3D molecular imaging
    Delcorte, Arnaud
    APPLIED SURFACE SCIENCE, 2008, 255 (04) : 954 - 958
  • [23] High-resolution 3 T MR microscopy imaging of arterial walls
    Sailer, Johannes
    Rand, Thomas
    Berg, Andreas
    Sulzbacher, Irene
    Peloschek, P.
    Hoelzenbein, Thomas
    Lammer, Johannes
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (05) : 771 - 777
  • [24] High-Resolution 3 T MR Microscopy Imaging of Arterial Walls
    Johannes Sailer
    Thomas Rand
    Andreas Berg
    Irene Sulzbacher
    P. Peloschek
    Thomas Hölzenbein
    Johannes Lammer
    CardioVascular and Interventional Radiology, 2006, 29 : 771 - 777
  • [25] Reproducibility of 3D 1H MR spectroscopic imaging of the prostate at 1.5T
    Lagemaat, Miriam W.
    Zechmann, Christian M.
    Futterer, Jurgen J.
    Weiland, Elisabeth
    Lu, Jianping
    Villeirs, Geert M.
    Holshouser, Barbara A.
    van Hecke, Paul
    Lemort, Marc
    Schlemmer, Heinz-Peter
    Barentsz, Jelle O.
    Roell, Stefan O.
    Heerschap, Arend
    Scheenen, Tom W. J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (01) : 166 - 173
  • [26] Fast High-Resolution 3D Radar Imaging Based on 3D FISTA
    Ren, Jiaying
    Lu, Xinfei
    Guan, Jian
    Yin, Zhiping
    Ehen, Weidong
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 815 - 818
  • [27] HIGH-RESOLUTION VARIABLE FLIP ANGLE 3D MR IMAGING OF TRABECULAR MICROSTRUCTURE INVIVO
    JARA, H
    WEHRLI, FW
    CHUNG, H
    FORD, JC
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) : 528 - 539
  • [28] SPINAL MR IMAGING - MULTIPLANAR REPRESENTATION FROM A SINGLE HIGH-RESOLUTION 3D ACQUISITION
    SHERRY, CS
    HARMS, SE
    MCCROSKEY, WK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) : 859 - 862
  • [29] RAPID HIGH-RESOLUTION 3D IMAGING IN MR DIAGNOSIS OF DISEASES OF THE KNEE-JOINT
    SKALEJ, M
    BONGERS, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (05): : 528 - 534
  • [30] High-Resolution In Utero 3D MR Imaging of Inner Ear Microstructures in Fetal Sheep
    Buhk, J. -H.
    Frisch, M.
    Yamamura, J.
    Graessner, J.
    Adam, G.
    Wedegaertner, U.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) : 2043 - 2046