High-resolution 3D MR spectroscopic imaging of the prostate at 3 T with the MLEV-PRESS sequence

被引:47
|
作者
Chen, Albert P.
Cunningham, Charles H.
Kurhanewicz, John
Xu, Duan
Hurd, Ralph E.
Pauly, John M.
Carvajal, Lucas
Karpodinis, Kostas
Vigneron, Daniel B. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] GE Hlth Care Technol, Menlo Pk, CA 94025 USA
关键词
spectroscopic imaging; prostate cancer; high field; MLEV-PRESS;
D O I
10.1016/j.mri.2006.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 3 T MLEV-point-resolved spectroscopy (PRESS) sequence employing optimized spectral-spatial and very selective outer-voxel suppression pulses was tested in 25 prostate cancer patients. At an echo time of 85 ins, the MLEV-PRESS sequence resulted in maximally upright inner resonances and minimal outer resonances of the citrate doublet of doublets. Magnetic resonance spectroscopic imaging (MRSI) exams performed at both 3 and 1.5 T for 10 patients demonstrated a 2.08 +/- 0.36-fold increase in signal-to-noise ratio (SNR) at 3 T as compared with 1.5 T for the center citrate resonances. This permitted the acquisition of MRSI data with a nominal spatial resolution of 0.16 cm(3) at 3 T with similar SNR as the 0.34-cm(3) data acquired at 1.5 T. Due to the twofold increase in spectral resolution at 3 T and the improved magnetic field homogeneity provided by susceptibility-matched endorectal coils, the choline resonance was better resolved from polyamine and creatine resonances as compared with 1.5 T spectra. In prostate cancer patients, the elevation of choline and the reduction of polyamines were more clearly observed at 3 T, as compared with 1.5 T MRSI. The increased SNR and corresponding spatial resolution obtainable at 3 T reduced partial volume effects and allowed improved detection of the presence and extent of abnormal metabolite levels in prostate cancer patients, as compared with 1.5 T MRSI. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:825 / 832
页数:8
相关论文
共 50 条
  • [41] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [42] Normal Pituitary Stalk: High-Resolution MR Imaging at 3T
    Satogami, N.
    Miki, Y.
    Koyama, T.
    Kataoka, M.
    Togashi, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (02) : 355 - 359
  • [43] 3D sensitivity encoded ellipsoidal MR spectroscopic imaging of gliomas at 3T
    Ozturk-Isik, Esin
    Chen, Albert. P.
    Crane, Jason C.
    Bian, Wei
    Xu, Duan
    Han, Eric T.
    Chang, Susan M.
    Vigneron, Daniel B.
    Nelson, Sarah J.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (09) : 1249 - 1257
  • [44] HIGH-RESOLUTION 3-D IMAGING WITH MR OF THE KNEE - CORRELATION WITH ARTHROSCOPY
    HOGERLE, S
    SIEVERS, KW
    ALBRECHT, T
    LETSCH, R
    LOHR, E
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (04): : 341 - 348
  • [45] Plaque Distribution of Basilar Artery Fenestration by 3D High-Resolution MR Vessel Wall Imaging
    Liu, Lei
    Zhang, Xue-Bin
    Lu, Shuo
    Liu, Zun-Jing
    Zhu, Xian-Jin
    CELL TRANSPLANTATION, 2019, 28 (07) : 851 - 855
  • [46] Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy
    Ebel, A
    Maudsley, AA
    MAGNETIC RESONANCE IMAGING, 2003, 21 (02) : 113 - 120
  • [47] High-resolution 3D proton spectroscopic imaging of the human brain at 3 T:: SNR issues and application for anatomy-matched voxel sizes
    Gruber, S
    Mlynárik, V
    Moser, E
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 299 - 306
  • [48] Non-invasive, high-resolution, 3D MR venography of the brain
    Reichenbach, JR
    Venkatesan, R
    Haacke, EM
    Kido, DK
    Lee, BC
    Kaiser, WA
    RADIOLOGY, 1997, 205 : 1138 - 1138
  • [49] 3D high-resolution cardiac collateral zone imaging by CT
    Pearlman, JD
    Laham, R
    Simons, M
    Raptopoulos, VD
    RADIOLOGY, 1997, 205 : 1354 - 1354
  • [50] Pulsed laser illumination enables high-resolution 3D imaging
    Logan, Ritchie, 1600, PennWell Publishing Co. (50):