Voltammetry of the erythromycin-modified glassy carbon electrode and interaction with DNA

被引:2
|
作者
Lu, XQ [1 ]
Zhou, XB [1 ]
Chen, J [1 ]
Kang, JW [1 ]
Gao, JZ [1 ]
机构
[1] NW Normal Univ, Inst Chem, Lanzhou 730070, Peoples R China
关键词
erythromycin; chemically modified electrode; interaction; DNA;
D O I
10.1080/00032710008543046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemically modified electrode (CME) which was constructed by covalently attaching Erythromycin (ERM) to a glassy carbon (GC) surface was investigated in Tris-HCl buffer (pH=6.0) by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). In the potential range -0.5 to +0.4V, CME yields a pair of stable redox waves. It is the carbonyl group of the ERM molecule immobilized on the GC surface that behaves as a mio-electron redox process involving one proton. The interaction of CME with DNA was also studied by DPV. The CME shows the same interaction with DNA as that in the solution. And the interactive model between ERM and DNA was proved by fluorescence in aqueous solutions.
引用
收藏
页码:193 / 207
页数:15
相关论文
共 50 条
  • [21] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Seyfullah Madakbaş
    Senem Kamiloǧlu
    Ece Kök Yetimoǧlu
    Journal of Analytical Chemistry, 2015, 70 : 725 - 730
  • [22] Determination of diquat at a Nafion film modified glassy carbon electrode using electrocatalytic voltammetry
    Lu, TW
    Sun, IW
    ELECTROANALYSIS, 2000, 12 (08) : 605 - 609
  • [23] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [24] Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, IGR
    LaScalea, MA
    ELECTROANALYSIS, 1997, 9 (02) : 110 - 114
  • [25] Hierarchically ordered porous nitrogen doped carbon modified a glassy carbon electrode for voltammetry detection of quercetin
    Wang, Ying
    Qiao, Mengfei
    Mamat, Xamxikamar
    Hu, Xun
    Hu, Guangzhi
    MATERIALS RESEARCH BULLETIN, 2021, 136 (136)
  • [26] VOLTAMMETRY OF IRIDIUM(IV) ON A GLASSY-CARBON ELECTRODE
    KABANOVA, OL
    STRILCHENKO, TG
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1986, 41 (05): : 697 - 701
  • [27] Anodic voltammetry of tramadol hydrochloride at a glassy carbon electrode
    王桂芬
    李海南
    刘英红
    毕淑云
    李春哲
    延边大学学报(自然科学版), 2006, (01) : 29 - 32
  • [28] Oxidative voltammetry of sulfanilamide at glassy carbon electrode.
    Frazier, T
    Iwunze, MO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U453 - U453
  • [29] Electroanalytical Investigation of Paracetamol on Glassy Carbon Electrode by Voltammetry
    Engin, C.
    Yilmaz, S.
    Saglikoglu, G.
    Yagmur, S.
    Sadikoglu, M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1916 - 1926
  • [30] DNA immobilization on nano-gold modified glassy carbon electrode
    Lin, XQ
    Miao, Q
    Jin, BK
    CHINESE CHEMICAL LETTERS, 1999, 10 (02) : 157 - 160