Voltammetry of the erythromycin-modified glassy carbon electrode and interaction with DNA

被引:2
|
作者
Lu, XQ [1 ]
Zhou, XB [1 ]
Chen, J [1 ]
Kang, JW [1 ]
Gao, JZ [1 ]
机构
[1] NW Normal Univ, Inst Chem, Lanzhou 730070, Peoples R China
关键词
erythromycin; chemically modified electrode; interaction; DNA;
D O I
10.1080/00032710008543046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemically modified electrode (CME) which was constructed by covalently attaching Erythromycin (ERM) to a glassy carbon (GC) surface was investigated in Tris-HCl buffer (pH=6.0) by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). In the potential range -0.5 to +0.4V, CME yields a pair of stable redox waves. It is the carbonyl group of the ERM molecule immobilized on the GC surface that behaves as a mio-electron redox process involving one proton. The interaction of CME with DNA was also studied by DPV. The CME shows the same interaction with DNA as that in the solution. And the interactive model between ERM and DNA was proved by fluorescence in aqueous solutions.
引用
收藏
页码:193 / 207
页数:15
相关论文
共 50 条
  • [31] DNA Immobilization on Nano-Gold Modified Glassy Carbon Electrode
    Xiang Qin LIN
    Qian MIAO
    Bao Kang JIN(Department of Chemistry. University of Science and Technology of China
    ChineseChemicalLetters, 1999, (02) : 157 - 160
  • [32] Electrochemical reduction of metronidazole at a DNA-modified glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, I
    LaScalea, MA
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (02): : 175 - 178
  • [33] Adsorption stripping voltammetry of phenol at Nafion-modified glassy carbon electrode in the presence of surfactants
    Yi, HC
    Wu, KB
    Hu, SS
    Cui, DF
    TALANTA, 2001, 55 (06) : 1205 - 1210
  • [34] Impedance and voltammetry detection of bromate in food samples using NiPcMWCNTs modified glassy carbon electrode
    Sheriff Aweda Balogun
    Omolola Esther Fayemi
    Journal of Analytical Science and Technology, 14
  • [35] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [36] Stripping Voltammetry on a new Modified Glassy Carbon Electrode for Lead Content Determination in Soft Water
    Vasile, Gabriela Geanina
    Arnold, Georgiana Luiza
    Buica, George Octavian
    Diacu, Elena
    Ungureanu, Eleonora Mihaela
    Dinu, Cristina
    REVISTA DE CHIMIE, 2018, 69 (01): : 21 - 26
  • [37] Impedance and voltammetry detection of bromate in food samples using NiPcMWCNTs modified glassy carbon electrode
    Balogun, Sheriff Aweda
    Fayemi, Omolola Esther
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 14 (01)
  • [38] Interaction of an antidepressant buzepide methiodide with DNA immobilized on the glassy carbon electrode
    Kalanur, Shankara S.
    Seetharamappa, J.
    Prashanth, S. N.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 82 (02) : 438 - 442
  • [39] Study of 2-Nitrofluorene Interaction with DNA at a Glassy Carbon Electrode
    Skalova, Stepanka
    Stavkova, Klara
    Vyskocil, Vlastimil
    Barek, Jiri
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 196 - 200
  • [40] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Nguyen, Do Mai
    Toan Tran, Thanh Tam
    Doan, Manh Dung
    Le, Van Thuan
    Dinh, Quang Khieu
    Chemosphere, 2022, 303