Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole

被引:0
|
作者
Seyfullah Madakbaş
Senem Kamiloǧlu
Ece Kök Yetimoǧlu
机构
[1] Marmara University,Faculty of Art and Science, Chemistry Department
来源
关键词
differential pulse voltammetry; modified glassy carbon electrode; methylparaben; polypyrrole;
D O I
暂无
中图分类号
学科分类号
摘要
A new modified glassy carbon electrode (GCE) based on a synthesized polypyrrole (PPy) was developed for the determination of methylparaben by differential pulse voltammetry (DPV). PPy was covalently immobilized on GCE surface using tetraethyl ammonium perchlorate (TEAP) and acetonitrile (ACN). Methylparaben was oxidized by differential pulse voltammetry and a peak was observed at 1.20 V. The calibration curve obtained with differential pulse voltammetry was linear in the concentration range from 0.01 to 5 mM methylparaben with a limit of detection of 8 ×10−3 mM and RSD of 0.11%. The improved method was applied to the determination of methylparaben in cream samples using the differential pulse voltammetry method.
引用
收藏
页码:725 / 730
页数:5
相关论文
共 50 条
  • [1] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Madakbas, Seyfullah
    Kamiloglu, Senem
    Yetimoglu, Ece Kok
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 725 - 730
  • [2] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Nguyen, Do Mai
    Toan Tran, Thanh Tam
    Doan, Manh Dung
    Le, Van Thuan
    Dinh, Quang Khieu
    Chemosphere, 2022, 303
  • [3] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Do Mai Nguyen
    Thanh Tam Toan Tran
    Manh Dung Doan
    Van Thuan Le
    Quang Khieu Dinh
    CHEMOSPHERE, 2022, 303
  • [4] Determination of trimebutine in pharmaceuticals by differential pulse voltammetry at a glassy carbon electrode
    Adhoum, N
    Monser, L
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (04) : 619 - 623
  • [5] Electrochemical determination of nonylphenol using differential pulse voltammetry based on a graphene-DNA-modified glassy carbon electrode
    Zeng, Lixuan
    Zhang, Aizhen
    Zhu, Xiaohua
    Zhang, Chuyi
    Liang, Yong
    Nan, Junmin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 703 : 153 - 157
  • [6] Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion®
    Farag, Amir Shaaban
    Pravcova, Katerina
    Ceslova, Lenka
    Vytras, Karel
    Sys, Milan
    ELECTROANALYSIS, 2019, 31 (08) : 1511 - 1516
  • [7] Determination of tetracycline residue in pork by differential pulse voltammetry using activated glassy carbon electrode
    Huong, Nguyen Thu
    Hien, Nguyen Thi Minh
    Thuy, Tran Thi Diem
    Ai, Nguyen Thi Ngoc
    Anh, Le Diep Quoc
    VIETNAM JOURNAL OF CHEMISTRY, 2023, 61 (01) : 65 - 73
  • [8] Electrochemical Determination of Butachlor by Differential Pulse Voltammetry (DPV) by an Electropolymerized Polypyrrole Molecular Imprinted Polymer (MIP) Modified Glassy Carbon Electrode (GCE)
    Li, Hao
    Tang, Jianshe
    Chen, Zhubin
    Xiang, Li
    ANALYTICAL LETTERS, 2023, 56 (17) : 2725 - 2737
  • [9] A Carbon Nanotube Modified Electrode for Determination of Caffeine by Differential Pulse Voltammetry
    Habibi, Biuck
    Abazari, Mehri
    Pournaghi-Azar, Mohammad Hossien
    CHINESE JOURNAL OF CATALYSIS, 2012, 33 (11) : 1783 - 1790
  • [10] Determination of melatonin by differential pulse voltammetry at modified carbon paste electrode
    Bekheit, GE
    ASIAN JOURNAL OF CHEMISTRY, 2000, 12 (02) : 541 - 547