Heavy ion radiation damage in double-sided silicon strip detectors

被引:3
|
作者
Livingston, K [1 ]
Woods, PJ [1 ]
Davinson, T [1 ]
Shotter, AC [1 ]
机构
[1] UNIV EDINBURGH,DEPT PHYS & ASTRON,EDINBURGH EH9 3JZ,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1016/0168-9002(95)00808-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A(252)Cf fission fragment source was used to produce heavy-ion radiation damage in a double-sided silicon strip detector. It was found that a good quality fission fragment spectrum (as determined by the peak to valley ration N-L/N-V) could not be achieved for radiation incident on the p(+) face of the detector. However, for radiation incident on the n(+) face, the ratio N-L/N-V remained adequate up to an accumulated dose of similar to 4 X 10(6) fragments mm(-2). For the measurement of alphas, typical resolution deteriorated from an initial 30 keV FWHM to 50 keV FWHM at a dose of similar to 8 X 10(6) fragments mm(-2) for radiation incident on the n(+) face, and similar to 6 X 10(6) for radiation incident on the p(+) face. The interstrip resistance in one region of the n(+) face broke down completely after a relatively small radiation doses incident on that face. Further investigation of this is still required.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [1] Heavy ion radiation damage in double-sided silicon strip detectors
    Livingston, K.
    Woods, P.J.
    Davinson, T.
    Shotter, A.C.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 370 (2-3): : 445 - 451
  • [2] A radiation damage test for double-sided silicon strip detectors
    Iwata, Y
    Ohsugi, T
    Ikeda, M
    Kitabayashi, H
    Ohmoto, T
    Kondo, T
    Unno, Y
    Terada, S
    Kohriki, T
    Takashima, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 114 - 120
  • [3] DOUBLE-SIDED SILICON STRIP DETECTORS IN PISA
    BATIGNANI, G
    BOSISIO, L
    FOCARDI, E
    FORTI, F
    GIORGI, M
    MARANGONI, D
    RIZZO, G
    TONELLI, G
    TRIGGIANI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2): : 98 - 102
  • [4] Studies of double-sided, double metal silicon strip detectors
    Alexander, J.P.
    Bebek, C.J.
    Browder, T.E.
    Dobbins, J.A.
    Gray, S.G.
    Honscheid, K.
    Jones, C.D.
    Katayama, N.
    Katris, J.S.
    Selen, M.
    Wurthwein, F.
    Gronberg, J.
    Morrison, R.J.
    Hale, D.L.
    Korte, C.
    et. al.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A342 (01) : 282 - 286
  • [5] SIGNAL SIMULATIONS FOR DOUBLE-SIDED SILICON STRIP DETECTORS
    LESLIE, J
    SEIDEN, A
    UNNO, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 557 - 562
  • [6] Radiation hardness of the HERA-B double-sided silicon strip detectors
    Bauer, C
    Glebe, T
    Knöpfle, KT
    Pugatch, V
    Schwingenheuer, B
    Abt, I
    Dressel, M
    Masciocchi, S
    Perschke, T
    Schaller, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 116 - 120
  • [7] Characterization and calibration of radiation-damaged double-sided silicon strip detectors
    Kaya, L.
    Vogt, A.
    Reiter, P.
    Birkenbach, B.
    Hirsch, R.
    Arnswald, K.
    Hess, H.
    Seidlitz, M.
    Steinbach, T.
    Warr, N.
    Wolf, K.
    Stahl, C.
    Pietralla, N.
    Limboeck, T.
    Meerholz, K.
    Lutter, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 855 : 109 - 117
  • [8] STUDIES OF DOUBLE-SIDED, DOUBLE METAL-SILICON STRIP DETECTORS
    ALEXANDER, JP
    BEBEK, CJ
    BROWDER, TE
    DOBBINS, JA
    GRAY, SG
    HONSCHEID, K
    JONES, CD
    KATAYAMA, N
    KATRIS, JS
    SELEN, M
    WURTHWEIN, F
    GRONBERG, J
    MORRISON, RJ
    HALE, DL
    KORTE, C
    KYRE, S
    NELSON, HN
    NELSON, TK
    QIAO, C
    SPERKA, DJ
    TAJIMA, H
    CINABRO, D
    HENDERSON, S
    YAMAMOTO, H
    ARTUSO, M
    SOBOLEWSKI, Z
    CHAN, S
    COWEN, DF
    MILLER, JS
    BALEST, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01): : 282 - 286
  • [9] A STUDY ON THE INTERSTRIP CAPACITANCE OF DOUBLE-SIDED SILICON STRIP DETECTORS
    YAMAMOTO, K
    YAMAMURA, K
    SAITO, K
    KONMURA, M
    NAKAMURA, M
    NIWA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2): : 222 - 227
  • [10] Application of double-sided silicon strip detectors to Compton cameras
    Aono, Hiroyuki
    Takeda, Shin'ichiro
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Kokubun, Motohide
    Watanabe, Shin
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    Okuyama, Sho
    Tajima, Hiroyasu
    Fukazawa, Yasushi
    Kawachi, Naoki
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021