Heavy ion radiation damage in double-sided silicon strip detectors

被引:3
|
作者
Livingston, K [1 ]
Woods, PJ [1 ]
Davinson, T [1 ]
Shotter, AC [1 ]
机构
[1] UNIV EDINBURGH,DEPT PHYS & ASTRON,EDINBURGH EH9 3JZ,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1016/0168-9002(95)00808-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A(252)Cf fission fragment source was used to produce heavy-ion radiation damage in a double-sided silicon strip detector. It was found that a good quality fission fragment spectrum (as determined by the peak to valley ration N-L/N-V) could not be achieved for radiation incident on the p(+) face of the detector. However, for radiation incident on the n(+) face, the ratio N-L/N-V remained adequate up to an accumulated dose of similar to 4 X 10(6) fragments mm(-2). For the measurement of alphas, typical resolution deteriorated from an initial 30 keV FWHM to 50 keV FWHM at a dose of similar to 8 X 10(6) fragments mm(-2) for radiation incident on the n(+) face, and similar to 6 X 10(6) for radiation incident on the p(+) face. The interstrip resistance in one region of the n(+) face broke down completely after a relatively small radiation doses incident on that face. Further investigation of this is still required.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [31] Fabrication of double-sided thallium bromide strip detectors
    Hitomi, Keitaro
    Nagano, Nobumichi
    Onodera, Toshiyuki
    Kim, Seong-Yun
    Ito, Tatsuya
    Ishii, Keizo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 823 : 15 - 19
  • [32] Double-sided TlBr strip detectors for SPECT application
    Hitomi, K.
    Kikuchi, Y.
    Nakhostin, M.
    Shoji, T.
    Ishii, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S171 - S171
  • [33] Implementation of a digital data readout system for double-sided silicon strip detectors for ion and alpha particle spectroscopy
    Maendl, R. R.
    Ackermann, D.
    Hessberger, F. P.
    Schmidt, K.
    Zimmermann, L.
    25TH INTERNATIONAL CONGRESS ON CONDITION MONITORING AND DIAGNOSTIC ENGINEERING (COMADEM 2012), 2012, 364
  • [34] Studies of double-sided silicon microstrip detectors
    Seidel, SC
    Bruner, NL
    Frautschi, MA
    Hoeferkamp, MR
    Patton, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 128 - 136
  • [35] READOUT OF DOUBLE-SIDED SILICON STRIP DETECTORS WITH HIGH-DENSITY INTEGRATED ELECTRONICS
    BECKER, H
    CATTANEO, P
    DIETL, H
    HAUFF, D
    LANGE, E
    LUTZ, G
    MOSER, HG
    SCHWARZ, AS
    SETTLES, R
    HOLL, P
    BUTTLER, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 246 - 250
  • [36] Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
    Abt, I
    Andricek, L
    Bauer, C
    Baumann, I
    Fox, H
    Halley, A
    Knopfle, KT
    Kroha, H
    Richter, RH
    Riechmann, K
    Rietz, M
    Rubsam, R
    Seywerd, H
    StDenis, R
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 28 - 32
  • [37] Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
    Abt, I
    Andricek, L
    Bauer, C
    Fox, H
    Halley, A
    Kroha, H
    Richter, RH
    Riechmann, K
    Rietz, M
    Rubsam, R
    Seywerd, H
    StDenis, R
    Baumann, I
    Knopfle, KT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1113 - 1118
  • [38] A Low Mass On-Chip Readout Scheme for Double-Sided Silicon Strip Detectors
    Irmler, C.
    Bergauer, T.
    Frankenberger, A.
    Friedl, M.
    Gfall, I.
    Higuchi, T.
    Ishikawa, A.
    Joo, C.
    Kah, D. H.
    Kang, K. H.
    Rao, K. K.
    Kato, E.
    Mohanty, G. B.
    Negishi, K.
    Onuki, Y.
    Shimizu, N.
    Tsuboyama, T.
    Valentan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 109 - 112
  • [39] DOUBLE-SIDED CAPACITIVELY COUPLED SILICON STRIP DETECTORS ON A 100MM WAFER
    BRENNER, R
    HIETANEN, I
    LINDGREN, J
    ORAVA, R
    RONNQVIST, C
    SCHULMAN, T
    TUUVA, T
    VOUTILAINEN, M
    ANDERSSON, M
    LEINONEN, K
    RONKAINEN, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 502 - 506
  • [40] Silicon pixel detectors of a double-sided guard ring structure for radiation hardness
    Cho, H
    Chien, CY
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2001, 39 (02) : 225 - 229