Microstructure-based numerical computational method for the insertion torque of dental implant

被引:0
|
作者
Li, Luli [1 ,2 ]
Zhang, Song [1 ,2 ]
Li, Quhao [1 ,2 ]
Bian, Cuirong [3 ]
Zhang, Airong [1 ,2 ]
机构
[1] Shandong Univ, Sch Mech Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Univ, Key Lab High Efficiency & Clean Mech Manufacture, Minist Educ, Jinan, Shandong, Peoples R China
[3] Shandong Univ, Dept Prosthodont, Qilu Hosp, Jinan 250012, Shandong, Peoples R China
关键词
Dental implant; Fabric tensor; Insertion torque; Microstructural solid model; Volume fraction; VERTEBRAL TRABECULAR BONE; LIMIT ANALYSIS; WOLFFS LAW; DENSITY; ARCHITECTURE; PREDICT; QUALITY; SITES;
D O I
10.1016/j.jmbbm.2019.06.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone quality has a significant effect on the insertion torque of dental implant. In most clinical studies, bone density is used as a gold standard in predicting insertion torque. By contrast, trabecular microstructure is ignored. In this study, a microstructure-based numerical computational method with high accuracy and efficiency for the insertion torque of dental implant was proposed by introducing two microscopic variables, namely, volume fraction and fabric tensor. First, two kinds of 3D microstructural solid models with same volume fraction and fabric tensor were established on the basis of the microstructural topology of six reference specimens. Second, a new numerical simulation method based on homogenous theory was used to explore the material models of these 3D microstructural solid models at the microscopic scale. Then, the anisotropic material models of specimens were developed on the basis of the mixture rule. Thereafter, a numerical simulation based on the anisotropic finite element (FE) model was carried out to acquire the insertion torque. To demonstrate the efficiency and accuracy of the simulation based on the anisotropic FE model, numerical simulations based on isotropic FE model and micro-computer tomography (micro-CT) FE models were also implemented as comparisons. Comparison of the simulated peak insertion torques of the anisotropic, isotropic, and micro-CT FE models with insertion experiments demonstrated the feasibility and potential of the proposed method. The anisotropic FE model reduced the time consumption by 91.85% and enhanced the accuracy by 11.82% compared with the micro-CT and isotropic FE models, respectively.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 50 条
  • [41] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [42] Computational assessment of the microstructure-dependent plasticity of lamellar gray cast iron - Part I: Methods and microstructure-based models
    Metzger, M.
    Seifert, T.
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2015, 66 : 184 - 193
  • [43] Microstructure-Based Random Finite Element Method Simulation of Frost Heave: Theory and Implementation
    Dong, Shaoyang
    Yu, Xiong
    TRANSPORTATION RESEARCH RECORD, 2018, 2672 (52) : 347 - 357
  • [44] Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis
    Ovesy, Marzieh
    Indermaur, Michael
    Zysset, Philippe K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 98 : 301 - 310
  • [45] A novel perfusion-based method for cochlear implant electrode insertion
    Kale, Sushrut
    Cervantes, Vanessa M.
    Wu, Mailing R.
    Pisano, Dominic V.
    Sheth, Nakul
    Olson, Elizabeth S.
    HEARING RESEARCH, 2014, 314 : 33 - 41
  • [46] Microstructure-based modelling of hydraulic fracturing in silicified metamorphic rock using the cohesive element method
    Liu, Shuo
    Thoeni, Klaus
    Feng, Runhua
    Bona, Andrej
    Sarmadivaleh, Mohammad
    Engineering Fracture Mechanics, 2022, 276
  • [47] A novel computational method for real-time preoperative assessment of primary dental implant stability
    Olsen, S
    Ferguson, SJ
    Sigrist, C
    Fritz, WR
    Nolte, LP
    Hallermann, W
    Caversaccio, M
    CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (01) : 53 - 59
  • [48] Microstructure-based stress analysis and evaluation for porous ceramics by homogenization method with digital image-based modeling
    Takano, N
    Zako, M
    Kubo, F
    Kimura, K
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2003, 40 (05) : 1225 - 1242
  • [49] Microstructure-based modelling of hydraulic fracturing in silicified metamorphic rock using the cohesive element method
    Liu, Shuo
    Thoeni, Klaus
    Feng, Runhua
    Bona, Andrej
    Sarmadivaleh, Mohammad
    ENGINEERING FRACTURE MECHANICS, 2022, 276
  • [50] Thermodynamic method for establishment of relationship between icephobicity/superhydrophobicity and microstructure-Based on computing for adhesion work
    Zhang, H. Y.
    Long, H.
    Yang, Y. L.
    Pan, J. F.
    Huang, L. S.
    Zhang, X. K.
    METHODSX, 2019, 6 : 513 - 526