Microstructure-based numerical computational method for the insertion torque of dental implant

被引:0
|
作者
Li, Luli [1 ,2 ]
Zhang, Song [1 ,2 ]
Li, Quhao [1 ,2 ]
Bian, Cuirong [3 ]
Zhang, Airong [1 ,2 ]
机构
[1] Shandong Univ, Sch Mech Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Univ, Key Lab High Efficiency & Clean Mech Manufacture, Minist Educ, Jinan, Shandong, Peoples R China
[3] Shandong Univ, Dept Prosthodont, Qilu Hosp, Jinan 250012, Shandong, Peoples R China
关键词
Dental implant; Fabric tensor; Insertion torque; Microstructural solid model; Volume fraction; VERTEBRAL TRABECULAR BONE; LIMIT ANALYSIS; WOLFFS LAW; DENSITY; ARCHITECTURE; PREDICT; QUALITY; SITES;
D O I
10.1016/j.jmbbm.2019.06.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone quality has a significant effect on the insertion torque of dental implant. In most clinical studies, bone density is used as a gold standard in predicting insertion torque. By contrast, trabecular microstructure is ignored. In this study, a microstructure-based numerical computational method with high accuracy and efficiency for the insertion torque of dental implant was proposed by introducing two microscopic variables, namely, volume fraction and fabric tensor. First, two kinds of 3D microstructural solid models with same volume fraction and fabric tensor were established on the basis of the microstructural topology of six reference specimens. Second, a new numerical simulation method based on homogenous theory was used to explore the material models of these 3D microstructural solid models at the microscopic scale. Then, the anisotropic material models of specimens were developed on the basis of the mixture rule. Thereafter, a numerical simulation based on the anisotropic finite element (FE) model was carried out to acquire the insertion torque. To demonstrate the efficiency and accuracy of the simulation based on the anisotropic FE model, numerical simulations based on isotropic FE model and micro-computer tomography (micro-CT) FE models were also implemented as comparisons. Comparison of the simulated peak insertion torques of the anisotropic, isotropic, and micro-CT FE models with insertion experiments demonstrated the feasibility and potential of the proposed method. The anisotropic FE model reduced the time consumption by 91.85% and enhanced the accuracy by 11.82% compared with the micro-CT and isotropic FE models, respectively.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 50 条
  • [21] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (05) : 726 - 732
  • [22] Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants
    Schwitalla, Andreas Dominik
    Zimmermann, Tycho
    Spintig, Tobias
    Abou-Emara, Mohamed
    Lackmann, Justus
    Mueller, Wolf-Dieter
    Houshmand, Alireza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 85 - 89
  • [23] Microstructure-Based Numerical Modeling of Pitting Corrosion in 316 Stainless Steel
    Kota, N.
    Qidwai, S. M.
    Lewis, A. C.
    DeGiorgi, V. G.
    CORROSION, PASSIVITY, AND ENERGY: A SYMPOSIUM IN HONOR OF DIGBY D. MACDONALD, 2013, 50 (31): : 155 - 164
  • [24] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    IMPLANTOLOGIE, 2008, 16 (01): : 11 - 20
  • [25] Microstructure-Based Numerical Simulation of the Tensile Behavior of SiCp/Al Composites
    Kan, Y.
    Liu, Z. G.
    Zhang, S. H.
    Zhang, L. W.
    Cheng, M.
    Song, H. W.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (03) : 1069 - 1076
  • [26] Modeling SAOS Yield Stress of Cement Suspensions: Microstructure-Based Computational Approach
    Ukrainczyk, Neven
    Thiedeitz, Mareike
    Kraenkel, Thomas
    Koenders, Eddie
    Gehlen, Christoph
    MATERIALS, 2020, 13 (12) : 1 - 17
  • [27] Topology optimization: A new microstructure-based design domain method
    Gea, HC
    COMPUTERS & STRUCTURES, 1996, 61 (05) : 781 - 788
  • [28] Impact of dental implant insertion method on the pen-implant bone tissue - An experimental study
    Stamatovic, Novak
    Matic, Smiljana
    Tatic, Zoran
    Petkovic-Curcin, Aleksandra
    Vojvodic, Danilo
    Rakic, Mia
    VOJNOSANITETSKI PREGLED, 2013, 70 (09) : 807 - 816
  • [29] Microstructure-based numerical modeling method for effective permittivity of ceramic/polymer composites -: art. no. 104104
    Jylhä, L
    Honkamo, J
    Jantunen, H
    Sihvola, A
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (10)
  • [30] Correlation Between Dental Implant Insertion Torque and Mandibular Alveolar Bone Density in Osteopenic and Osteoporotic Subjects
    Chai, John
    Chau, Anson C. M.
    Chu, Frederick C. S.
    Chow, Tak W.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 888 - 893