Microstructure-based numerical computational method for the insertion torque of dental implant

被引:0
|
作者
Li, Luli [1 ,2 ]
Zhang, Song [1 ,2 ]
Li, Quhao [1 ,2 ]
Bian, Cuirong [3 ]
Zhang, Airong [1 ,2 ]
机构
[1] Shandong Univ, Sch Mech Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Univ, Key Lab High Efficiency & Clean Mech Manufacture, Minist Educ, Jinan, Shandong, Peoples R China
[3] Shandong Univ, Dept Prosthodont, Qilu Hosp, Jinan 250012, Shandong, Peoples R China
关键词
Dental implant; Fabric tensor; Insertion torque; Microstructural solid model; Volume fraction; VERTEBRAL TRABECULAR BONE; LIMIT ANALYSIS; WOLFFS LAW; DENSITY; ARCHITECTURE; PREDICT; QUALITY; SITES;
D O I
10.1016/j.jmbbm.2019.06.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone quality has a significant effect on the insertion torque of dental implant. In most clinical studies, bone density is used as a gold standard in predicting insertion torque. By contrast, trabecular microstructure is ignored. In this study, a microstructure-based numerical computational method with high accuracy and efficiency for the insertion torque of dental implant was proposed by introducing two microscopic variables, namely, volume fraction and fabric tensor. First, two kinds of 3D microstructural solid models with same volume fraction and fabric tensor were established on the basis of the microstructural topology of six reference specimens. Second, a new numerical simulation method based on homogenous theory was used to explore the material models of these 3D microstructural solid models at the microscopic scale. Then, the anisotropic material models of specimens were developed on the basis of the mixture rule. Thereafter, a numerical simulation based on the anisotropic finite element (FE) model was carried out to acquire the insertion torque. To demonstrate the efficiency and accuracy of the simulation based on the anisotropic FE model, numerical simulations based on isotropic FE model and micro-computer tomography (micro-CT) FE models were also implemented as comparisons. Comparison of the simulated peak insertion torques of the anisotropic, isotropic, and micro-CT FE models with insertion experiments demonstrated the feasibility and potential of the proposed method. The anisotropic FE model reduced the time consumption by 91.85% and enhanced the accuracy by 11.82% compared with the micro-CT and isotropic FE models, respectively.
引用
收藏
页码:137 / 147
页数:11
相关论文
共 50 条
  • [1] Analytical model for dental implant insertion torque
    Yang, Baixuan
    Irastorza-Landa, Ainara
    Heuberger, Peter
    Ploeg, Heidi-Lynn
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 131
  • [2] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Li, Luli
    Zhang, Song
    Li, Quhao
    Bian, Cuirong
    Zhang, Airong
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2022, 35 (01)
  • [3] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35 (03) : 106 - 119
  • [4] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35
  • [5] Actual microstructure-based numerical method for mesomechanics of concrete
    Chen, S.
    Yue, Z. Q.
    Kwan, A. K. H.
    COMPUTERS AND CONCRETE, 2013, 12 (01): : 1 - 18
  • [6] Experimental study to establishing the insertion torque on dental implant
    Isabel Lopez-Gualdron, Clara
    Fernando Galeano-Arrieta, Carlos
    Cesar Pinillos, Julio
    Carlos Moreno, Juan
    REVISTA ITECKNE, 2014, 11 (01): : 17 - 26
  • [7] Numerical Simulation of Dental Implant Insertion Process
    Jaworski, Nazariy
    Iwaniec, Marek
    2017 XIIITH INTERNATIONAL CONFERENCE ON PERSPECTIVE TECHNOLOGIES AND METHODS IN MEMS DESIGN (MEMSTECH), 2017, : 59 - 61
  • [8] Insertion Torque Function Analysis of Novel Dental Implant Geometry
    Pammer, D.
    Bognar, E.
    FIRST EUROPEAN BIOMEDICAL ENGINEERING CONFERENCE FOR YOUNG INVESTIGATORS, 2015, 50 : 83 - 86
  • [9] Effect of insertion factors on dental implant insertion torque/energy-experimental results
    Yang, Baixuan
    Irastorza-Landa, Ainara
    Heuberger, Peter
    Ploeg, Heidi-Lynn
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 112
  • [10] Measurement of bone deformation and insertion torque during dental implant installation
    Nascimento, Larissa Ramos Xavier Coutinho
    Torelly, Guilherme Monteiro
    Elias, Carlos Nelson
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 29 (01):