Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases

被引:105
|
作者
Ruiseor Vazquez, Pablo R. [1 ,2 ]
David Galletti, Jonatan [1 ,2 ]
Minguez, Natalia [1 ,2 ]
Delrivo, Marianella [1 ]
Fuentes Bonthoux, Fernando [1 ]
Pfortner, Tomas [1 ]
Gaston Galletti, Jeremias [1 ,3 ]
机构
[1] EGOS Clin Ocular Studies Lab, Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Div Ophthalmol, Hosp Clin Jose San Martin, Buenos Aires, DF, Argentina
[3] Natl Acad Med, CONICET, Inst Expt Med, Buenos Aires, DF, Argentina
关键词
POSTERIOR CORNEAL ELEVATION; NORMAL EYES; THICKNESS; PARAMETERS; ECTASIA; VOLUME; SHAPE;
D O I
10.1016/j.ajo.2014.03.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate Pentacam ectasia detection indices in topographically normal patients and in subclinical keratoconus cases. DESIGN: Prospective, observational case series. METHODS: SETTING: Institutional. PATIENTS: Group 1 comprised 1 eye from 189 patients with unremarkable topography and Groups 2 and 3 included the better and worse eyes, respectively, of 55 keratoconic patients. Group 2 eyes with normal topography (n = 37) were considered subclinical keratoconus cases. OBSERVATION PROCEDURE: Pentacam Scheimpflug tomography. MAIN OUTCOME MEASURES: Eleven Pentacam ectasia detection indices. RESULTS: All Pentacam ectasia indices significantly differed between Groups 1 and 2 and were correlated with keratoconus grade. Only 99 eyes (52%) in Group 1 had normal values for every index, whereas 7 subclinical keratoconus eyes (19%) showed 2 or fewer abnormal indices. Standardized relational thickness and overall deviation indices had 73% and 89% sensitivity for subclinical keratoconus, respectively. Both average and maximum pachymetric progression indices offered 84% sensitivity while maximum relational thickness index showed 78% sensitivity for subclinical keratoconus. Optimized cutoff values for subclinical keratoconus increased the sensitivity of the standardized and maximum relational thickness indices. CONCLUSION: Pentacam Scheimpflug tomography can detect most subclinical keratoconus cases with unremarkable topography, but performance is not as good as reported and varies considerably for each index. The overall deviation, average and maximum pachymetric progression, and maximum relational thickness indices offer the highest sensitivity, which can be improved by using optimized cutoff values. Specificity constitutes an issue for some indices and up to 10% of subclinical keratoconus cases may go undetected by this technology. (Am J Ophthalmol 2014;158:32-40. (C) 2014 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:32 / 40
页数:9
相关论文
共 50 条
  • [31] Reliability of successive corneal tomography and biomechanical measurements by Pentacam® and Corvis ST® in keratoconus patients without treatment and after corneal crosslinking
    Xanthopoulou, Kassandra
    Munteanu, Cristian
    Seitz, Berthold
    Belin, Michael
    Flockerzi, Elias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [32] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Herber, Robert
    Lenk, Janine
    Pillunat, Lutz E.
    Raiskup, Frederik
    EYE AND VISION, 2022, 9 (01)
  • [33] Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
    Robert Herber
    Janine Lenk
    Lutz E. Pillunat
    Frederik Raiskup
    Eye and Vision, 9
  • [34] Agreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients
    Asawaworarit, Rosepon
    Satitpitakul, Vannarut
    Taweekitikul, Parichart
    Pongpirui, Krit
    PLOS ONE, 2022, 17 (05):
  • [35] COMPUTED-TOMOGRAPHY FINDINGS IN CLINICALLY NORMAL AND ABNORMAL THYROID PATIENTS
    ARGER, PH
    JENNINGS, AS
    GORDON, LF
    COLEMAN, BG
    AXEL, L
    KRESSEL, HY
    BARON, RL
    CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1985, 9 (02): : 111 - 117
  • [36] Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
    Prospero Ponce, Claudia Maria
    Rocha, Karolinne Maia
    Smith, Scott D.
    Krueger, Ronald R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06): : 1055 - 1062
  • [37] Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry
    Grewal, Dilraj S.
    Brar, Gagandeep S.
    Grewal, Satinder P. S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 954 - 964
  • [38] Bronchoscopy in patients with haemoptysis and normal computed tomography of the chest is unlikely to result in significant findings
    Bonlokke, Soren
    Guldbrandt, Louise Mahncke
    Rasmussen, Torben Riis
    DANISH MEDICAL JOURNAL, 2015, 62 (08):
  • [39] US findings in euthyroid patients with positive antithyroid autoantibody tests compared to normal and hypothyroid cases
    Acar, Turker
    Ozbek, Suha Sureyya
    Erdogan, Mehmet
    Ozgen, Ahmet Gokhan
    Demirel, Selcuk Orhan
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2013, 19 (04) : 265 - 270
  • [40] Evaluation of central corneal thickness as measured by pentacam and retinal and choroidal thickness as measured by optical coherence tomography before and after uneventful cataract phacoemulsification in normal and diabetic patients without retinopathy
    Ali, Bahaa El Din A.
    Salman, Abd El Rahman G.
    Mohamad, Ahmed A.
    Shaker, Michael Waheed F.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2018, 111 (01) : 37 - 42