Pentacam Scheimpflug Tomography Findings in Topographically Normal Patients and Subclinical Keratoconus Cases

被引:105
|
作者
Ruiseor Vazquez, Pablo R. [1 ,2 ]
David Galletti, Jonatan [1 ,2 ]
Minguez, Natalia [1 ,2 ]
Delrivo, Marianella [1 ]
Fuentes Bonthoux, Fernando [1 ]
Pfortner, Tomas [1 ]
Gaston Galletti, Jeremias [1 ,3 ]
机构
[1] EGOS Clin Ocular Studies Lab, Buenos Aires, DF, Argentina
[2] Univ Buenos Aires, Div Ophthalmol, Hosp Clin Jose San Martin, Buenos Aires, DF, Argentina
[3] Natl Acad Med, CONICET, Inst Expt Med, Buenos Aires, DF, Argentina
关键词
POSTERIOR CORNEAL ELEVATION; NORMAL EYES; THICKNESS; PARAMETERS; ECTASIA; VOLUME; SHAPE;
D O I
10.1016/j.ajo.2014.03.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate Pentacam ectasia detection indices in topographically normal patients and in subclinical keratoconus cases. DESIGN: Prospective, observational case series. METHODS: SETTING: Institutional. PATIENTS: Group 1 comprised 1 eye from 189 patients with unremarkable topography and Groups 2 and 3 included the better and worse eyes, respectively, of 55 keratoconic patients. Group 2 eyes with normal topography (n = 37) were considered subclinical keratoconus cases. OBSERVATION PROCEDURE: Pentacam Scheimpflug tomography. MAIN OUTCOME MEASURES: Eleven Pentacam ectasia detection indices. RESULTS: All Pentacam ectasia indices significantly differed between Groups 1 and 2 and were correlated with keratoconus grade. Only 99 eyes (52%) in Group 1 had normal values for every index, whereas 7 subclinical keratoconus eyes (19%) showed 2 or fewer abnormal indices. Standardized relational thickness and overall deviation indices had 73% and 89% sensitivity for subclinical keratoconus, respectively. Both average and maximum pachymetric progression indices offered 84% sensitivity while maximum relational thickness index showed 78% sensitivity for subclinical keratoconus. Optimized cutoff values for subclinical keratoconus increased the sensitivity of the standardized and maximum relational thickness indices. CONCLUSION: Pentacam Scheimpflug tomography can detect most subclinical keratoconus cases with unremarkable topography, but performance is not as good as reported and varies considerably for each index. The overall deviation, average and maximum pachymetric progression, and maximum relational thickness indices offer the highest sensitivity, which can be improved by using optimized cutoff values. Specificity constitutes an issue for some indices and up to 10% of subclinical keratoconus cases may go undetected by this technology. (Am J Ophthalmol 2014;158:32-40. (C) 2014 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:32 / 40
页数:9
相关论文
共 50 条
  • [21] Biomechanical Analysis of Subclinical Keratoconus With Normal Topographic, Topometric, and Tomographic Findings
    Koc, Mustafa
    Aydemir, Emre
    Tekin, Kemal
    Inanc, Merve
    Kosekahya, Pinar
    Kiziltoprak, Hasan
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (04) : 247 - 252
  • [22] New artificial intelligence index based on Scheimpflug corneal tomography to distinguish subclinical keratoconus from healthy corneas
    Almeida, Gildasio Castello, Jr.
    Guido, Rodrigo Capobianco
    Balarin Silva, Henrique Monteiro
    Brandao, Cinara Cassia
    de Mattos, Luiz Carlos
    Lopes, Bernardo T.
    Machado, Aydano Pamponet
    Ambrosio, Renato, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (10): : 1168 - 1174
  • [23] Ectasia Detection by Anterior Segment Optical Coherence Tomography in Scheimpflug Tomographically Normal Keratoconus Fellow Eyes
    Naujokaitis, Tadas
    Augustin, Victor A.
    Son, Hyeck-Soo
    Koeppe, Maximilian
    Kovalchuk, Bogdana
    Auffarth, Gerd U.
    Khoramnia, Ramin
    CORNEA, 2024, 43 (07) : 812 - 819
  • [24] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [25] Scheimpflug Tomographic Indices for Classifying Normal, Down Syndrome and Clinical Keratoconus in Pediatric Patients
    Oliveira, Renato Souza
    Gil, Joao Quadrado
    Rosa, Andreia
    Quadrado, Maria Joao
    Campos, Mauro
    DIAGNOSTICS, 2024, 14 (17)
  • [26] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Seyed Mohammad Ghoreishi
    Seyed Ali Akbar Mortazavi
    Zahra-Alsadat Abtahi
    Mohammad-Ali Abtahi
    Seyed Ali Sonbolestan
    Seyed-Hossein Abtahi
    Mohadeseh Mohammadinia
    Kimia Nekouie Isfahani
    International Ophthalmology, 2017, 37 : 965 - 971
  • [27] Evaluation of corneal topography and tomography in fellow eyes of unilateral keratoconus patients for early detection of subclinical keratoconus
    Thulasidas, Mithun
    Teotia, Prateek
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2415 - 2420
  • [28] Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer
    Said, Omar M.
    Kamal, Mahmoud
    Tawfik, Sara
    Saif, Ahmed Tamer Sayed
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [29] Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer
    Omar M. Said
    Mahmoud Kamal
    Sara Tawfik
    Ahmed Tamer Sayed Saif
    BMC Ophthalmology, 23
  • [30] Comparison of corneal thickness in patients with dry eye disease using the Pentacam rotating Scheimpflug camera and anterior segment optical coherence tomography
    Fujimoto, Keiichi
    Inomata, Takenori
    Okumura, Yuichi
    Iwata, Nanami
    Fujio, Kenta
    Eguchi, Atsuko
    Nagino, Ken
    Shokirova, Hurramhon
    Karasawa, Maria
    Murakami, Akira
    PLOS ONE, 2020, 15 (02):