Variability in low-flow oxygen delivery by nasal cannula evaluated in neonatal and infant airway replicas

被引:5
|
作者
Sabz, Mozhgan [1 ]
Tavernini, Scott [1 ]
Pillay, Kineshta [1 ]
Christianson, Cole [1 ]
Noga, Michelle [2 ]
Finlay, Warren H. [1 ]
Rouhani, Hossein [1 ]
Martin, Andrew R. [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Low-flow oxygen delivery; Nasal cannula; In vitro testing; Neonates; Infants; Airway replicas; Fraction of inspired oxygen; Oxygen concentration; Oxygen therapy; Supplemental oxygen; OBSTRUCTION; CHILDREN; HEALTHY;
D O I
10.1186/s12931-022-02260-x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The nasal cannula is considered a trusted and effective means of administering low-flow oxygen and is widely used for neonates and infants requiring oxygen therapy, despite an understanding that oxygen concentrations delivered to patients are variable. Methods: In the present study, realistic nasal airway replicas derived from medical scans of children less than 3 months old were used to measure the fraction of oxygen inhaled (FiO(2)) through nasal cannulas during low-flow oxygen delivery. Parameters influencing variability in FiO(2) were evaluated, as was the hypothesis that measured FiO(2) values could be predicted using a simple, flow-weighted calculation that assumes ideal mixing of oxygen with entrained room air. Tidal breathing through neonatal and infant nasal airway replicas was controlled using a lung simulator. Parameters for nasal cannula oxygen flow rate, nasal airway geometry, tidal volume, respiratory rate, inhalation/exhalation, or I:E ratio (t(i)/t(e)), breath waveform, and cannula prong insertion position were varied to determine their effect on measured FiO(2). In total, FiO(2) was measured for 384 different parameter combinations, with each combination repeated in triplicate. Analysis of variance (ANOVA) was used to assess the influence of parameters on measured FiO(2). Results: Measured FiO(2) was not appreciably affected by the breath waveform shape, the replica geometry, or the cannula position but was significantly influenced by the tidal volume, the inhalation time, and the nasal cannula flow rate. Conclusions: The flow-weighted calculation overpredicted FiO(2) for measured values above 60%, but an empirical correction to the calculation provided good agreement with measured FiO(2) across the full range of experimental data.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] COMPARISON OF NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE WITH LOW FLOW OXYGEN VERSUS HEATED, HUMIDIFIED HIGH FLOW NASAL CANNULA FOR ORAL FEEDING OF THE PREMATURE INFANT (CHOMP TRIAL): A PILOT STUDY
    Leibel, S. L.
    Castro, M.
    McBride, T.
    Sarmiento, K.
    Hassal, K.
    Shah, V.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2019, 67 (01) : 118 - 119
  • [32] A PHYSIOLOGIC STUDY OF HELIUM-OXYGEN GAS DELIVERY VIA HIGH-FLOW NASAL CANNULA IN AIRWAY OBSTRUCTION
    Speicher, Richard
    Slain, Katherine
    Gallagher, John
    Broberg, Meredith
    Shein, Steven
    Rotta, Alexandre
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [33] The low-flow or high-flow oxygen delivery system and a low-flow or high-flow nonrebreather mask
    Agarwal, Ritesh
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (09) : 1055 - 1055
  • [34] Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas
    Chen, John Z.
    Katz, Ira M.
    Pichelin, Marine
    Zhu, Kaixian
    Caillibotte, Georges
    Noga, Michelle L.
    Finlay, Warren H.
    Martin, Andrew R.
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2017, 12 : 2559 - 2571
  • [35] Aerosol Delivery Through Adult High Flow Nasal Cannula With Heliox and Oxygen
    Dailey, Patricia A.
    Harwood, Robert
    Walsh, Kyle
    Fink, James B.
    Thayer, Tina
    Gagnon, Greg
    Ari, Arzu
    RESPIRATORY CARE, 2017, 62 (09) : 1186 - 1192
  • [36] What are high-flow and low-flow oxygen delivery systems?
    Agarwal, R
    Gupta, D
    STROKE, 2005, 36 (10) : 2066 - 2067
  • [38] The Momentum Battle in an Upper Airway During High Flow Nasal Cannula Oxygen Therapy
    Kacinski, Robert
    Strasser, Wayne
    Leonard, Scott
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (01):
  • [39] Non-rebreather mask and low-flow nasal cannula vs high-flow nasal cannula in severe COVID-19 pneumonia in the emergency department
    Kamil, Muhammad Khidir Mohd
    Yoong, Khadijah Poh Yuen
    Azhar, Abdul Muhaimin Noor
    Bustam, Aida
    Abdullah, Ahmad Hariz
    Yusuf, Mohd Hafyzuddin Md
    Zambri, Aliyah
    Zahedi, Ahmad Zulkarnain Ahmad
    Shafie, Hidayah
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2023, 63 : 86 - 93
  • [40] Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for preterm infants
    Campbell, D. M.
    Shah, P. S.
    Shah, V.
    Kelly, E. N.
    JOURNAL OF PERINATOLOGY, 2006, 26 (09) : 546 - 549