Micro-CT artifacts reduction based on detector random shifting and fast data inpainting

被引:26
|
作者
Zhu, Yining [1 ]
Zhao, Mengliu [1 ]
Li, Hongwei [1 ]
Zhang, Peng [1 ]
机构
[1] Capital Normal Univ, Sch Math, CT Lab, Beijing 10048, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; scintillator defects; artifacts reduction; detector random shifting; exemplar-based data inpainting; multiscale; RING ARTIFACTS; OBJECT REMOVAL; MODEL; WAVELET; STRIPE;
D O I
10.1118/1.4790697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In Micro-CT systems based on optical coupling detectors, the defects of scintillator or CCD-camera would lead to heavy artifacts in reconstructed CT images. Meanwhile, different detector units usually suffer from inhomogeneous response, which also leads to artifacts in the CT images. Detector shifting is a simple and efficient method to remove the artifacts due to inhomogeneous responses of detector units. However, it does not work well for heavy artifacts due to defects in scintillator or CCD. The purpose of this paper is to develop a data preprocessing method to reduce both kinds of artifacts. Methods: A hybrid method which involves detector random shifting and data inpainting is proposed to correct the projection data, so as to suppress the artifacts in the reconstructed CT images. The defects in scintillator or CCD-camera lead to data lost in some areas of the projection data. The Criminisi algorithm is employed to recover the lost data. By detector random shifting, the location of the lost data in one view might be shifted away in adjacent views. This feature is utilized to design the search window, such that the best match patch shall be searched across adjacent views. By this way, the best match patches should really enjoy high similarity. As a result, the heavy artifacts due to defects of scintillator or CCD-camera should be suppressed. Furthermore, a multiscale tessellation method is proposed to locate the defects and similarity patches, which makes the Criminisi algorithm very fast. Results: The authors tested the proposed method on both simulated projection data and real projection data. Experiments show that the proposed method could correct the bad data in the projections quite well. Compared to other popular methods, such as linear interpolation, wavelet combining Fourier transform, and TV-inpainting, experimental results suggest that the CT images reconstructed from the preprocessed data sets by our method is significantly better in quality. Conclusions: They have proposed a hybrid method for projection data preprocessing which fits well to typical Micro-CT systems. The hybrid method could suppress the ring artifacts in the reconstructed CT images efficiently, while the spatial resolution is not reduced even with a critical eye. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] 4D micro-CT using fast prospective gating
    Guo, Xiaolian
    Johnston, Samuel M.
    Qi, Yi
    Johnson, G. Allan
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 257 - 271
  • [32] EFFECTIVE SINOGRAM-INPAINTING FOR METAL ARTIFACTS REDUCTION IN X-RAY CT IMAGES
    Kim, Youngshin
    Yoon, Seongbeak
    Yi, Juneho
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 597 - 600
  • [33] Comparative evaluation of cone beam CT and micro-CT on blooming artifacts in human teeth filled with bioceramic sealers
    Berkan Celikten
    Reinhilde Jacobs
    Karla de Faria Vasconcelos
    Yan Huang
    Eman Shaheen
    Laura Ferreira Pinheiro Nicolielo
    Kaan Orhan
    Clinical Oral Investigations, 2019, 23 : 3267 - 3273
  • [34] Comparative evaluation of cone beam CT and micro-CT on blooming artifacts in human teeth filled with bioceramic sealers
    Celikten, Berkan
    Jacobs, Reinhilde
    Vasconcelos, Karla de Faria
    Huang, Yan
    Shaheen, Eman
    Pinheiro Nicolielo, Laura Ferreira
    Orhan, Kaan
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (08) : 3267 - 3273
  • [35] Micro-CT data of complete metamorphosis process in Harmonia axyridis
    Shu, Runguo
    Xiao, Yiqi
    Zhang, Chaowei
    Liu, Ying
    Zhou, Hang
    Li, Fei
    SCIENTIFIC DATA, 2024, 11 (01)
  • [36] Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
    Zbijewski, Wojciech
    Beekman, Freek J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 817 - 827
  • [37] Estimation of the Acoustic Properties of the Random Packing Structures of Granular Materials: Estimation of the Sound Absorption Coefficient Based on Micro-CT Scan Data
    Sakamoto, Shuichi
    Suzuki, Kyosuke
    Toda, Kentaro
    Seino, Shotaro
    MATERIALS, 2023, 16 (01)
  • [38] Study on characterization of micro-fracture of shale based on micro-CT
    Gou Q.
    Xu S.
    Hao F.
    Yang F.
    Wang Y.
    Lu Y.
    Zhang A.
    Cheng X.
    Qing J.
    Gao M.
    Dizhi Xuebao/Acta Geologica Sinica, 2019, 93 (09): : 2372 - 2382
  • [39] Micro-CT based quantitative evaluation of caries excavation
    Neves, Aline de A.
    Coutinho, Eduardo
    Cardoso, Marcio Vivan
    Jaecques, Siegfried V.
    Van Meerbeek, Bart
    DENTAL MATERIALS, 2010, 26 (06) : 579 - 588
  • [40] Study of Scan Protocol for Exposure Reduction in Hybrid Spectral Micro-CT
    Opie, Alex M. T.
    Bennett, James R.
    Walsh, Michael
    Rajendran, Kishore
    Yu, Hengyong
    Xu, Qiong
    Butler, Anthony
    Butler, Philip
    Cao, Guohua
    Mohs, Aaron M.
    Wang, Ge
    SCANNING, 2014, 36 (04) : 444 - 455