Micro-CT artifacts reduction based on detector random shifting and fast data inpainting

被引:26
|
作者
Zhu, Yining [1 ]
Zhao, Mengliu [1 ]
Li, Hongwei [1 ]
Zhang, Peng [1 ]
机构
[1] Capital Normal Univ, Sch Math, CT Lab, Beijing 10048, Peoples R China
基金
中国国家自然科学基金;
关键词
Micro-CT; scintillator defects; artifacts reduction; detector random shifting; exemplar-based data inpainting; multiscale; RING ARTIFACTS; OBJECT REMOVAL; MODEL; WAVELET; STRIPE;
D O I
10.1118/1.4790697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In Micro-CT systems based on optical coupling detectors, the defects of scintillator or CCD-camera would lead to heavy artifacts in reconstructed CT images. Meanwhile, different detector units usually suffer from inhomogeneous response, which also leads to artifacts in the CT images. Detector shifting is a simple and efficient method to remove the artifacts due to inhomogeneous responses of detector units. However, it does not work well for heavy artifacts due to defects in scintillator or CCD. The purpose of this paper is to develop a data preprocessing method to reduce both kinds of artifacts. Methods: A hybrid method which involves detector random shifting and data inpainting is proposed to correct the projection data, so as to suppress the artifacts in the reconstructed CT images. The defects in scintillator or CCD-camera lead to data lost in some areas of the projection data. The Criminisi algorithm is employed to recover the lost data. By detector random shifting, the location of the lost data in one view might be shifted away in adjacent views. This feature is utilized to design the search window, such that the best match patch shall be searched across adjacent views. By this way, the best match patches should really enjoy high similarity. As a result, the heavy artifacts due to defects of scintillator or CCD-camera should be suppressed. Furthermore, a multiscale tessellation method is proposed to locate the defects and similarity patches, which makes the Criminisi algorithm very fast. Results: The authors tested the proposed method on both simulated projection data and real projection data. Experiments show that the proposed method could correct the bad data in the projections quite well. Compared to other popular methods, such as linear interpolation, wavelet combining Fourier transform, and TV-inpainting, experimental results suggest that the CT images reconstructed from the preprocessed data sets by our method is significantly better in quality. Conclusions: They have proposed a hybrid method for projection data preprocessing which fits well to typical Micro-CT systems. The hybrid method could suppress the ring artifacts in the reconstructed CT images efficiently, while the spatial resolution is not reduced even with a critical eye. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Dose reduction and image enhancement in micro-CT using deep learning
    Muller, Florence M.
    Maebe, Jens
    Vanhove, Christian
    Vandenberghe, Stefaan
    MEDICAL PHYSICS, 2023, 50 (09) : 5643 - 5656
  • [42] Reduction of aliasing artifacts in cone-beam CT images using data derivatives with respect to detector coordinates
    Zou, Y
    Pan, X
    Jiang, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [43] Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning
    Li, Jun Yuan
    Pow, Edmond Ho Nang
    Zheng, Li Wu
    Ma, Li
    Kwong, Dora Lai Wan
    Cheung, Lim Kwong
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 506 - 510
  • [44] First K-Edge Imaging With a Micro-CT Based on the XPAD3 Hybrid Pixel Detector
    Brunner, Franca Cassol
    Dupont, Mathieu
    Meessen, Christophe
    Boursier, Yannick
    Ouamara, Hamid
    Bonissent, Alain
    Kronland-Martinet, Carine
    Clemens, Jean-Claude
    Debarbieux, Franck
    Morel, Christian
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 103 - 108
  • [45] A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Lee, SY
    Cho, MH
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (24): : 4173 - 4185
  • [46] Fast Analysis of Maize Kernel Plumpness Characteristics Through Micro-CT Technology
    Shao, Meng
    Zhang, Ying
    Du, Jianjun
    Pan, Xiaodi
    Ma, Liming
    Wang, Jinglu
    Boehmer, Dennis
    Guo, Xinyu
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE XI, PT I, 2019, 545 : 31 - 39
  • [47] Computerized methodology for micro-CT and histological data inflation using an IVUS based translation map
    Athanasiou, Lambros S.
    Rigas, George A.
    Sakellarios, Antonis I.
    Exarchos, Themis P.
    Siogkas, Panagiotis K.
    Naka, Katerina K.
    Panetta, Daniele
    Pelosi, Gualtiero
    Vozzi, Federico
    Michalis, Lampros K.
    Parodi, Oberdan
    Fotiadis, Dimitrios I.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 65 : 168 - 176
  • [48] Fast method for ringing artifacts reduction in random phase-free kinoforms
    Chen, Chun
    Wang, Jun
    Xiao, Dan
    Wang, Qiong-Hua
    APPLIED OPTICS, 2019, 58 (05) : A13 - A20
  • [49] Reduction of metal artifacts using subtracted CT projection data
    Tolakanahalli, R
    Medow, JE
    Hsieh, J
    Chen, GH
    Mistretta, CA
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 636 - 643
  • [50] Efficient digitalization method for dental restorations using micro-CT data
    Changhwan Kim
    Seung Hoon Baek
    Taewon Lee
    Jonggun Go
    Sun Young Kim
    Seungryong Cho
    Scientific Reports, 7