Clinical implementation of pencil beam scanning proton therapy for liver cancer with forced deep expiration breath hold

被引:10
|
作者
Fracchiolla, Francesco [1 ]
Dionisi, Francesco [1 ]
Righetto, Roberto [1 ]
Widesott, Lamberto [1 ]
Giacomelli, Irene [1 ]
Cartechini, Giorgio [2 ]
Farace, Paolo [1 ]
Bertolini, Mattia [1 ]
Amichetti, Maurizio [1 ]
Schwarz, Marco [1 ,3 ]
机构
[1] Azienda Prov & Serv Sanitari APSS, Protontherapy Dept, Via Al Desert 14, I-38122 Trento, Italy
[2] Univ Trento, Trento, Italy
[3] TIFPA Trento Inst Fundamental Phys & Applicat, Trento, Italy
关键词
Proton therapy; Liver treatments; Interplay effect; Robustness analysis;
D O I
10.1016/j.radonc.2020.09.035
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To present our technique for liver cancer treatments with proton therapy in pencil beam scanning mode and to evaluate the impact of uncertainties on plan quality. Materials and Methods: Seventeen patients affected by liver cancer were included in this study. Patients were imaged and treated in forced breath-hold using the Active Breathing Coordinator system and monitored with an optical tracking system. Three simulation CTs were acquired to estimate the anatomical variability between breath-holds and generate an internal target volume (ITV). The treatment plans were optimized with a Single Field Optimization technique aimed at minimizing the use of range shifter. Plan robustness was tested simulating systematic range and setup uncertainties, as well as the interplay effect between breath-holds. The appropriateness of margin was further verified based on the actual positioning data acquired during treatment. Results: The dose distributions of the nominal plans achieved a satisfactory target coverage in 11 out of 17 patients, while in the remaining 6 D95 to the PTV was affected by the constraint on mean liver dose. The constraints for all other organs at risk were always within tolerances. The interplay effect had a limited impact on the dose distributions: the worst case scenario showed a D95 reduction in the ITV < 3.9 GyRBE and no OAR with D-1 > 105% of the prescription dose. The robustness analysis showed that for 13 out of 17 patients the ITV coverage in terms of D95 was better than D95 of the PTV in the nominal plan. For the remaining 4 patients, the maximum difference between ITV D95 and PTV D95 was <= 0.7% even for the largest simulated setup error and it was deemed clinically acceptable. Hot spots in the OARs were always lower than 105% of the prescription dose. Positioning images confirmed that the breath hold technique and the PTV margin were adequate to compensate for inter- and intra-breath-hold variations in liver position. Conclusion: We designed and clinically applied a technique for the treatment of liver cancer with proton pencil beam scanning in forced deep expiration breath-hold. The initial data on plan robustness and patient positioning suggest that the choices in terms of planning technique and treatment margins are able to reach the desired balance between target coverage and organ at risk sparing. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [21] Clinical Outcome of Pencil Beam Scanning Proton Therapy for Children With Rhabdomyosarcoma
    Leiser, D.
    Malyapa, R. S.
    Albertini, F.
    Kliebsch, U.
    Mikroutsikos, L.
    Morach, P.
    Bojaxhiu, B.
    Bolsi, A.
    Walser, M.
    Timmermann, B.
    Lomax, A. J.
    Schneider, R.
    Weber, D. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E547 - E548
  • [22] Clinical Implementation of Proton Therapy Using Pencil-Beam Scanning Delivery Combined With Static Apertures
    Baeumer, Christian
    Plaude, Sandija
    Khalil, Dalia Ahmad
    Geismar, Dirk
    Kramer, Paul-Heinz
    Kroninger, Kevin
    Nitsch, Christian
    Wulff, Joerg
    Timmermann, Beate
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [23] Evaluation and Commissioning of the SDX Spirometer Based System for Use in Proton Pencil Beam Scanning Treatment Under Deep Inspiration Breath-Hold
    Perles, L.
    Hobson, M.
    Gutierrez, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E768 - E769
  • [24] Proton therapy posterior beam approach with pencil beam scanning for esophageal cancer Clinical outcome, dosimetry, and feasibility
    Zeng, Yue-Can
    Vyas, Shilpa
    Dang, Quang
    Schultz, Lindsay
    Bowen, Stephen R.
    Shankaran, Veena
    Farjah, Farhood
    Oelschlager, Brant K.
    Apisarnthanarax, Smith
    Zeng, Jing
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (12) : 913 - 921
  • [25] A Planning Comparison of IMRT vs. Pencil Beam Scanning for Deep Inspiration Breath Hold Lung Cancers
    Mah, Dennis
    Yorke, Ellen
    Zemanaj, Entela
    Han, Zhiqiang
    Liu, Haoyang
    George, Jobin
    Lambiase, Jason
    Czmielewski, Christian
    Lovelock, D. Michael
    Rimner, Andreas
    Shepherd, Annemarie F.
    MEDICAL DOSIMETRY, 2022, 47 (01) : 26 - 31
  • [26] Implementation of proton therapy treatments with pencil beam scanning of targets with limited intrafraction motion
    Fracchiolla, Francesco
    Dionisi, Francesco
    Giacomelli, Irene
    Hild, Sebastian
    Esposito, Pier Giorgio
    Lorentini, Stefano
    Engwall, Erik
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 215 - 220
  • [27] Implementation of 4D proton therapy treatments with pencil beam scanning (PBS)
    Fracchiolla, F.
    Dionisi, F.
    Hild, S.
    Giacomelli, I.
    Lorentini, S.
    Engwall, E.
    Esposito, P. G.
    Amichetti, M.
    Schwarz, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1110 - S1111
  • [28] Pencil Beam Scanning:: a dynamical approach to proton therapy
    Sepulchre, R
    Gérard, M
    Marchand, B
    Prieels, D
    Bauvir, B
    IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 370 - 375
  • [29] The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy - An experimental study
    Gorgisyan, Jenny
    Lomax, Antony J.
    af Rosenschold, Per Munck
    Persson, Gitte F.
    Krieger, Miriam
    Colvill, Emma
    Scherman, Jonas
    Gagnon-Moisan, Francis
    Egloff, Martina
    Fattori, Giovanni
    Engelholm, Svend Aage
    Weber, Damien C.
    Perrin, Rosalind
    RADIOTHERAPY AND ONCOLOGY, 2019, 134 : 135 - 142
  • [30] Strategies for Motion Robust Proton Therapy With Pencil Beam Scanning for Esophageal Cancer
    Moller, Ditte Sloth
    Poulsen, Per Rugaard
    Hagner, Andreas
    Dufour, Mathieu
    Nordsmark, Marianne
    Nyeng, Tine Bisballe
    Mortensen, Hanna Rahbek
    Lutz, Christina Maria
    Hoffmann, Lone
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (02): : 539 - 548