The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy - An experimental study

被引:7
|
作者
Gorgisyan, Jenny [1 ,2 ,3 ,7 ]
Lomax, Antony J. [1 ,4 ]
af Rosenschold, Per Munck [3 ,5 ]
Persson, Gitte F. [2 ,8 ,9 ]
Krieger, Miriam [1 ,4 ]
Colvill, Emma [1 ]
Scherman, Jonas [5 ]
Gagnon-Moisan, Francis [1 ]
Egloff, Martina [1 ]
Fattori, Giovanni [1 ]
Engelholm, Svend Aage [2 ]
Weber, Damien C. [1 ,6 ]
Perrin, Rosalind [1 ,10 ]
机构
[1] ETH Domain, Paul Scherrer Inst, Zurich, Switzerland
[2] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Copenhagen, Denmark
[3] Univ Copenhagen, Niels Bohr Inst, Herlev, Denmark
[4] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[5] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[6] Univ Hosp Zurich, Radiat Oncol Dept, Zurich, Switzerland
[7] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[8] Univ Copenhagen, Herlev Hosp, Dept Oncol, Herlev, Denmark
[9] Univ Copenhagen, Dept Clin Med, Fac Med Sci, Herlev, Denmark
[10] Univ Klinikum Erlangen, Dept Med Radiat Phys, Strahlenklin, Univ Str 29, D-91054 Erlangen, Germany
关键词
4D phantom; PBS proton therapy; Breath-hold; Lung tumours; LUNG-TUMORS; RESPIRATORY MOTION; RADIOTHERAPY; UNCERTAINTIES; MITIGATION; PHANTOM; CANCER; ROBUSTNESS; TARGETS; THORAX;
D O I
10.1016/j.radonc.2019.01.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management in the treatment of lung cancer is necessary to assure highest quality of the delivered radiation therapy. In this study, the breath-hold technique is experimentally investigated for pencil beam scanned (PBS) proton therapy, with respect to the dosimetric effect of residual breath-hold motion. Material and methods: Three-dimensional (3D)-printed tumours extracted from CT scans of three patients were inserted into a dynamic anthropomorphic breathing phantom. The target was set up to move with the individual patient's tumour motion during breath-hold as previously assessed on fluoroscopy. Target dose was measured with radio-chromic film, and both single field uniform dose (SFUD) and intensity-modulated proton therapy (IMPT) plans were delivered. Experiments were repeated for each patient without any motion, to compute the relative dose deviation between static and breath-hold cases. Results: SFUD plans showed small dose deviations between static and breath-hold cases, as evidenced by the gamma pass rate (3%, 3 mm) of 85% or higher. Dose deviation was more evident for IMPT plans, with gamma pass rate reduced to 50-70%. Conclusions: The breath-hold technique is robust to residual intra-breath-hold motion for SFUD treatment plans, based on our experimental study. IMPT was less robust with larger detected dose deviations. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [1] Breath-hold motion effect in pencil beam scanned proton therapy for lung cancer - experimental study
    Gorgisyan, J.
    Lomax, A. J.
    af Rosenschold, P. Munck
    Persson, G. F.
    Rydhog, J. Scherman
    Gagnon-Moisan, F.
    Egloff, M.
    Fattori, G.
    Engelholm, S. A.
    Weber, D. C.
    Perrin, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S515 - S516
  • [2] The Simulated Effect of the Breath-Hold Reproducibility Treating Locally-Advanced Lung Cancer with Pencil Beam Scanned Proton Therapy
    Dueck, J.
    Perrin, R.
    Persson, G. F.
    Lomax, A.
    Josipovic, M.
    Engelholm, S. A.
    Weber, D. C.
    Munck, P.
    Rosenschold, A. F.
    MEDICAL PHYSICS, 2016, 43 (06) : 3490 - 3490
  • [3] Pencil beam scanning proton therapy for mediastinal lymphomas in deep inspiration breath-hold
    Horberger, F.
    Andersson, K.
    Enmark, M.
    Kristensen, I.
    Flejmer, A.
    Edvardsson, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S386 - S387
  • [4] Impact of beam angle choice on pencil beam scanning breath-hold proton therapy for lung lesions
    Gorgisyan, Jenny
    Perrin, Rosalind
    Lomax, Antony J.
    Persson, Gitte F.
    Josipovic, Mirjana
    Engelholm, Svend Aage
    Weber, Damien C.
    af Rosenschold, Per Munck
    ACTA ONCOLOGICA, 2017, 56 (06) : 853 - 859
  • [5] Feasibility of Pencil Beam Scanned Intensity Modulated Proton Therapy in Breath-hold for Locally Advanced Non-Small Cell Lung Cancer
    Gorgisyan, Jenny
    af Rosenschold, Per Munck
    Perrin, Rosalind
    Persson, Gitte F.
    Josipovic, Mirjana
    Belosi, Maria Francesca
    Engelholm, Svend Aage
    Weber, Damien C.
    Lomax, Antony J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (05): : 1121 - 1128
  • [6] Evaluation of Deep Inspiration Breath-Hold Technique for Post-Mastectomy Proton Pencil Beam Scanning Therapy
    Depauw, N.
    Patel, S.
    MacDonald, S.
    Lu, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3421 - 3422
  • [7] Pencil beam scanning proton therapy for mediastinal lymphomas in deep inspiration breath-hold: a retrospective assessment of plan robustness
    Hoerberger, Filip
    Andersson, Karin M.
    Enmark, Marika
    Kristensen, Ingrid
    Flejmer, Anna
    Edvardsson, Anneli
    ACTA ONCOLOGICA, 2024, 63 : 62 - 69
  • [8] Robustness of the breath-hold approach for early stage lung cancer with spot scanned proton therapy
    Dueck, J.
    Knopf, A.
    Albertini, F.
    Persson, G.
    Josipovic, M.
    Aznar, M.
    Lomax, T.
    af Rosenschold, P. Munck
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S89 - S90
  • [9] Technical challenges in the treatment of mediastinal lymphomas by proton pencil beam scanning and deep inspiration breath-hold
    Righetto, Roberto
    Fracchiolla, Francesco
    Widesott, Lamberto
    Lorentini, Stefano
    Dionisi, Francesco
    Rombi, Barbara
    Scartoni, Daniele
    Vennarini, Sabina
    Schwarz, Marco
    Farace, Paolo
    RADIOTHERAPY AND ONCOLOGY, 2022, 169 : 43 - 50
  • [10] Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy
    Dueck, Jenny
    Knopf, Antje-Christin
    Lomax, Antony
    Albertini, Francesca
    Persson, Gitte F.
    Josipovic, Mirjana
    Aznar, Marianne
    Weber, Damien C.
    af Rosenschold, Per Munck
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 534 - 541