The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy - An experimental study

被引:7
|
作者
Gorgisyan, Jenny [1 ,2 ,3 ,7 ]
Lomax, Antony J. [1 ,4 ]
af Rosenschold, Per Munck [3 ,5 ]
Persson, Gitte F. [2 ,8 ,9 ]
Krieger, Miriam [1 ,4 ]
Colvill, Emma [1 ]
Scherman, Jonas [5 ]
Gagnon-Moisan, Francis [1 ]
Egloff, Martina [1 ]
Fattori, Giovanni [1 ]
Engelholm, Svend Aage [2 ]
Weber, Damien C. [1 ,6 ]
Perrin, Rosalind [1 ,10 ]
机构
[1] ETH Domain, Paul Scherrer Inst, Zurich, Switzerland
[2] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Copenhagen, Denmark
[3] Univ Copenhagen, Niels Bohr Inst, Herlev, Denmark
[4] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[5] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Radiat Phys, Lund, Sweden
[6] Univ Hosp Zurich, Radiat Oncol Dept, Zurich, Switzerland
[7] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[8] Univ Copenhagen, Herlev Hosp, Dept Oncol, Herlev, Denmark
[9] Univ Copenhagen, Dept Clin Med, Fac Med Sci, Herlev, Denmark
[10] Univ Klinikum Erlangen, Dept Med Radiat Phys, Strahlenklin, Univ Str 29, D-91054 Erlangen, Germany
关键词
4D phantom; PBS proton therapy; Breath-hold; Lung tumours; LUNG-TUMORS; RESPIRATORY MOTION; RADIOTHERAPY; UNCERTAINTIES; MITIGATION; PHANTOM; CANCER; ROBUSTNESS; TARGETS; THORAX;
D O I
10.1016/j.radonc.2019.01.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Motion management in the treatment of lung cancer is necessary to assure highest quality of the delivered radiation therapy. In this study, the breath-hold technique is experimentally investigated for pencil beam scanned (PBS) proton therapy, with respect to the dosimetric effect of residual breath-hold motion. Material and methods: Three-dimensional (3D)-printed tumours extracted from CT scans of three patients were inserted into a dynamic anthropomorphic breathing phantom. The target was set up to move with the individual patient's tumour motion during breath-hold as previously assessed on fluoroscopy. Target dose was measured with radio-chromic film, and both single field uniform dose (SFUD) and intensity-modulated proton therapy (IMPT) plans were delivered. Experiments were repeated for each patient without any motion, to compute the relative dose deviation between static and breath-hold cases. Results: SFUD plans showed small dose deviations between static and breath-hold cases, as evidenced by the gamma pass rate (3%, 3 mm) of 85% or higher. Dose deviation was more evident for IMPT plans, with gamma pass rate reduced to 50-70%. Conclusions: The breath-hold technique is robust to residual intra-breath-hold motion for SFUD treatment plans, based on our experimental study. IMPT was less robust with larger detected dose deviations. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [31] Evaluation and Commissioning of the SDX Spirometer Based System for Use in Proton Pencil Beam Scanning Treatment Under Deep Inspiration Breath-Hold
    Perles, L.
    Hobson, M.
    Gutierrez, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E768 - E769
  • [32] Respiratory liver motion estimation and its effect on scanned proton beam therapy
    Zhang, Ye
    Boye, D.
    Tanner, C.
    Lomax, A. J.
    Knopf, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07): : 1779 - 1795
  • [33] Proton pencil beam scanning treatment with feedback based voluntary moderate breath hold
    Wang, Peng
    Tang, Shikui
    Leach, Karla
    Mangona, Victor
    Simone, Charles B., II
    Langen, Katja
    Chang, Chang
    MEDICAL DOSIMETRY, 2020, 45 (03) : E10 - E15
  • [34] A motion model-guided 4D dose reconstruction for pencil beam scanned proton therapy
    Duetschler, A.
    Huang, L.
    Fattori, G.
    Meier, G.
    Bula, C.
    Hrbacek, J.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [35] Evaluation of Dosimetric Gain and Uncertainties in Proton Therapy Delivery with Scanned Pencil Beam in Treatment of Base-of-skull and Spinal Tumors
    Trofimov, A.
    Kang, J.
    Unkelbach, J.
    Adams, J. A.
    Zhang, X.
    Bortfeld, T.
    Liebsch, N. J.
    DeLaney, T. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S133 - S134
  • [36] First Clinical Report of Pencil Beam Scanned Proton Therapy for Mediastinal Lymphoma
    Plastaras, J. P.
    Vogel, J.
    Elmongy, H.
    Zeng, C.
    Svoboda, J.
    Both, S.
    Maity, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E497 - E497
  • [37] MITIGATION OF RESIDUAL MOTION EFFECTS IN SCANNED ION BEAM THERAPY
    Richter, D.
    Steidl, P.
    Trautmann, J.
    Schwarzkopf, A.
    Kraemer, M.
    Gemmel, A.
    Naumann, J.
    Panse, R.
    Saito, N.
    Jaekel, O.
    Durante, M.
    Bert, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S72 - S73
  • [38] Breath-Hold Intensity Modulated Proton Therapy (BH-IMPT) for Lung SBRT: Feasibility Study
    Lin, M.
    Jolinta, L.
    Feigenberg, S. J.
    Mehta, M. P.
    DSouza, W. D.
    Langen, K. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S142 - S142
  • [39] Evaluation of daily residual pancreatic tumor motion for deep-inspiration breath-hold radiotherapy
    Mao, Weihua
    Wu, Binbin
    Ding, Kai
    Han-Oh, Sarah
    Narang, Amol
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [40] Dosimetric Impact of intra- and inter-fraction motion in liver pencil beam scanning proton therapy
    Nankali, Saber
    Worm, Esben Schjodt
    Thomsen, Jakob Borup
    Stick, Line Bjerregaard
    Hoyer, Morten
    Weber, Britta
    Mortensen, Hanna Rahbek
    Poulsen, Per Rugaard
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4193 - S4196